Download PFLOTRAN User Manual
Transcript
PFLOTRAN User Manual 7.3.5 §7.3.5 August 14, 2015 PFLOTRAN Input File Listing for the PFLOTRAN input file coupling Richards mode to a tracer is given below. Note that the stratigraphic zone specification in REGION is grid independent as is the grid size specification in keyword GRID. Therefore to change the grid spacing only the line: NXYZ 1 1 136, needs to be changed. Also note that lines beginning with # are read as a comment as is input following ‘!’. Note that the input file looks for the RESTART file for the transient run in the subdirectory: ./ss/sx115-restart.chk. PFLOTRAN input file sx115.in: #Description: 1D test problem for tracer transport for Hanford SX-115 waste tank. SIMULATION SIMULATION_TYPE SUBSURFACE PROCESS_MODELS SUBSURFACE_FLOW flow MODE RICHARDS / SUBSURFACE_TRANSPORT transport GLOBAL_IMPLICIT / / END SUBSURFACE #=========================== chemistry ======================================== CHEMISTRY PRIMARY_SPECIES Tracer / OUTPUT all FREE_ION / END #=========================== runtime ========================================== #CHECKPOINT 100000 RESTART ./ss/sx115-restart.chk 0.d0 #OVERWRITE_RESTART_TRANSPORT #WALLCLOCK_STOP 11.75 #=========================== solver options =================================== TIMESTEPPER FLOW #MAX_STEPS -1 TS_ACCELERATION 8 INITIALIZE_TO_STEADY_STATE 1.d0 END NEWTON_SOLVER FLOW #RTOL 1.d-12 RTOL 1.d-20 #ATOL 1.d-12 #STOL 1.e-60 #DTOL 1.e4 ITOL_UPDATE 1.d0 #NO_INFINITY_NORM #NO_PRINT_CONVERGENCE #PRINT_DETAILED_CONVERGENCE END < 166 >