3.
Go to the Settings / Ethernet page on the Web MMI and switch Wake on LAN to ON and
the Inactivity timer to the required time, in this example 5 minutes, and press Apply.
4.
In the M2M configuration page on the WebUI, set the Always On Context to Enabled and
set the IP address of the LAN Device (in this case 192.168.128.99) in the Always On
Context section / Static ACA IP Address. Also make sure that the Ping Configuration /
Context Watchdog is disabled.
5.
Reboot the UT. This can be done by the ‘reboot now’ option on the pop-up window after
the configuration changes, or from the ‘reboot’ button on the Home page.
6.
Close all applications on the PC.
7.
After 5 minutes of inactivity, the UT will power down. Once it has powered down, you can
open up a web browser to cause the UT to power up and it will be fully functional within
2 minutes.
Hughes 9502 BGAN M2M System Integrators Guide
Page 18