… Cover unused connections with the cover caps supplied.
… Only connect plugs and other components that fulfill protection class IP
67 and that are certified for a temperate range from -20 °C to +55 °C.
2.2.1
Setting up the device
… Set up/mount the device in a location where the ambient conditions specified in the technical data are adhered to.
2.2.2
Wall mounting
… Prepare the drill holes at the installation point.
… Mount the device on a level surface with four M5 screws.
Figure 3: BAT54-F wall mounting
2.2.3
Mounting the device outdoors
Note: Set up the antenna close to the device. Use the shortest antenna cable
possible.
Note: Problems with cable-free installations outdoors are usually due to reduced performance caused by corrosion processes in the antenna cable and
the cable connectors.
Therefore, you should always seal the outdoor cable connectors with waterresistent tape.
„ Pole mounting
The BAT54-F devices are designed for pole mounting with the additional
BAT54-F pole mounting set (see on page 37 "Accessories").
The BAT 54 pole mounting set is designed for:
X Pole diameter: 37 mm to 60 mm
X Maximum permitted wind load: 220 km/h.