Download Light Commercial

Transcript
connector in this hard duct line in order to keep the HRV acoustically isolated
and separately grounded (electrically) from the air handler. This will avoid a
possible shock hazard to service people if a short to ground develops in one of
the devices. It may be necessary to install a separate fresh air supply ductwork
system if the heating is other than forced air.
When installing an HRV, the designer and installer should be aware of local
codes that may require smoke detectors and / or firestops in the HVAC or HRV
ductwork. Because an HRV is designed to bring fresh air into the building, structures may require a supply voltage interrupt when fire or smoke or flame sensors
are triggered or central fire system is activated.
Supply air grilles may be ceiling or high wall mounted. Avoid incoming fresh air
grilles that could cause a direct draft on the occupants as the incoming air may
be below room temperature. A reheat duct heater can be installed to improve occupant comfort. Information on electric or hydronic duct heaters is commercially
available.
INSTALLATION TIPS
1. Whichever method is chosen to operate the SHRV600RD, keep in mind
that Air – to – Air exchangers are not “ booster fans “, and are not normally
sized to ventilate at a steady rate.
To achieve optimum performance from the SHRV600RD, the desired
ventilation rate (speed of the system) should be reached before the contaminant has reached its’ maximum.
2.
It is recommended that backdraft dampers be installed in the supply and
exhaust ductwork to the outside, to prevent air from entering in through the
HRV when the HRV is OFF. Failure to install backdraft dampers may result
in damage to HVAC equipment and / or other building components.
INTEGRATED HVAC SYSTEM
Increasingly, the HRV has become an integral component of the commercial
HVAC system. HRV’s are very versatile, being able to provide fresh air directly
to the return air plenum of a rooftop heat / cool unit or into a ceiling return air
plenum or directly into the ceiling space near the air handlers intake. Special
care and attention should be given if connecting this unit to any air handler or
other unit that may draw more than the SHRV600RD is designed to accommodate.
Installations where it is satisfactory to provide general exhaust from the space,
the air to be exhausted may be taken directly from the return air plenum to the
HRV as it is drawn back to the air handler. Fresh air supplied by the HRV is then
introduced directly into the return air plenum but at a location closer to the air
handler. The air handler would have a constant running blower to effectively
13