Download user`s manual cooling system test & refill kit model mv4525
Transcript
Dynamic Pressure/Vacuum/Temperature Test (Engine On) continued 11. When testing is complete, connect the Drain Hose to the Shuttle Valve using the quick-connect. Make sure the quick-connect sleeve snaps forward to lock the connection (Fig. 32). 12. Place the opposite end of the Drain Hose into a container appropriate to capture hot, pressurized coolant. Use the Hose Clip to secure the Drain Hose in position (Fig. 33). 13. Shift the shuttle valve to the the “Open” position, allowing the hot fluid and pressure to be expelled (Fig. 34). Fig. 32 14. Once all pressure is relieved, cautiously disconnect components, clean and store them properly. Caution: Hot fluid being expelled through the test equipment will cause quick-connects and other metal components to become hot. Handle such components with care, using a rag if necessary. 15. Refill the radiator or coolant bottle to the proper level, and replace the cap. Fig. 33 Fig. 34 Page Number - 12 Form 822947