Transcript
Warnings and cautions Avoid possible damage when suddenly apply pressure to low pressure and small chamber gauges. Do not exceed the safety pressure limit(7MPa). Compressed air may cause problem in explosive or corruptive environment. Do not shift between pressure and vacuum mode under pressure. Do not over tighten connectors to avoid any damage. Store the pump in the dry and non-corruptive environment. Any security problems or damages caused by incorrect operation, is beyond ConST group's responsibility. Specification Pressure range: a. Vacuum:(-95 to 0)KPa b. Pressure:(0 to 2.5)MPa Temperature: (0~50)℃ Humidity: < 85%RH Adjusting fineness: 10Pa Safety pressure: < 7MPa Pressure media: Air Size: 240×120×130mm(315mm×198mm×140mm for ConST117) Weight: 1.3kg (2.6kg for ConST117) Remark:If local atmosphere pressure is 100kPa, the vacuum can reach to -95kPa; If local atmosphere pressure is P, the vacuum can reach to - (95P/100)kPa. 让校准更轻松! Calibration can be easy! Accessories ConST 116 Handheld Pneumatic Pump User's Manual flexible hose adapter NPT1/4 sealing ring ZL200620119357.2 (This manual is fit for the ConST 117, too.) adapter NPT1/2 adapter M20×1.5 plug M20×1.5 spanner ×2 ×1 ConST NPT1/4 NPT1/2 M20×1.5 551- 208 200mm ×1 ×20 ×1 ×1 ×1 Configuration & Air routine 1 2 3 4 1 - M20×1.5 connector 2 - Release valve Air routine 3 (clockwise to close/ anticlockwise to open) 3 - Isolating valve (isolate the calibration from pressurizing system) 4 - Pressure lever 5 - Fine adjust handles 7 2 (clockwise to increase pressure) 6 - Security bolt pin (use it to ensure safety) 7 6 5 4 7 - Pressure/vacuum selector 5 (Pressure: pull it out; Vacuum: push it in) Troubleshooting Problems Hard to use pressure lever Hard to pressurize Hard to use vernier Not easy to turn the fittings Solutions Causes The isolating valve is not open. Open the isolating valve. A. Release valve is not closed. Close the release valve. B. The sealing ring is broken or loosen. Replace sealing ring (PR#:ZL200620119357.2). C. P/V selector is in wrong position. Pressure: pull it out; Vacuum: push it in. A. The isolating valve is not closed. Close the isolating valve. B. The gauges is not tightened. Tighten the reference gauge or the gauge under test. C. The sealing ring is aged or frayed. Replace sealing ring. D. The thread surface is not smooth. Put in a Teflon seals and turn it tightly. E. The connector type is unmatched. Use the right and suitable adapter. F. The impurity blocks the air routine. Repeat pressurizing several times and then release it suddenly, make airflow to bring the impurity out. A. Too tightly turned last time! Do not apply much force to close the fittings and valves. B. The new pump is not smooth. The new pump needs time to abrade. C. The threads have no lubrication. Lubricate the thread. Basic Operation Connection A Open to atmosphere DIGITAL PRESSURE C ALIBRATOR B DIGITAL PRESSURE C ALIBRATOR Units Units SW SW V mA COM V mA COM 24V 24V ConST273 ConST273 open pressure switch dial gauge Pre-pressure pressure transmitter C flexible hose Zeroing should be operated under this condition only. D Fine adjust process open Pressurizing process E R DIGITAL PRESSURE CALIBRATO DIGITAL PRESSURE CALIBRATOR R DIGITAL PRESSURE CALIBRATO Units Units Units operate it to get the ⑤ desired value (0~6)MPa (0~6)MPa (0~6)MPa operate it to get the ② desired value ① close,do not use too much force ④ close,do not use too much force ③ open set it to the mid ② position of its travel ① Open ② fine adjust ① push the security bolt pin in Decrease pressure process F G Vacuum process Repeat Vacuum process DIGITAL PRESSURE CALIBRATOR H R DIGITAL PRESSURE CALIBRATO DIGITAL PRESSURE CALIBRATOR Units 0.06 Units Units 0.04 0.06 真空表 (0~6)MPa 0.04 真空表 08 0.02 - 0.1 0 (0~6)MPa 08 0.02 - 0.1 0 (0~6)MPa it slowly to get the desired ① open value, and close! ② fine adjust pull out ② operate it to get the ⑤ desired value operate it to get the ② desired value it must be open when ④ close(but select the pressure/vacuum) ① open ① open ③ push in,select the vacuum position Decrease vacuum process I Calibration procedure 1st point R DIGITAL PRESSURE CALIBRATO Units 0.06 Pressure 0.04 真空表 (0~6)MPa 08 0.02 - 0.1 0 open it slowly to get the desired ② value, and close! ① close ③ fine adjust N point : A → B → C → D → E → D … E → D → F Dial gauge Pressure transmitter 1st point Vacuum 2nd point 2nd point N point : A → B → G → D → H → D … H → D → I Pressure : A → B → C → D Vacuum : A → B → G → D Pressure switch increase pressure till the switch move increase pressure till the switch move F → D F → D decrease pressure till the switch resume decrease pressure till the switch resume the end the end Remark: ConST group has made a concerted effort to provide complete and current information for the proper use of the equipment. The product specifications and other information contained this manual are subject to change without notice. Beijing ConST Instruments Technology Inc.