Warnings and cautions Avoid possible damage when suddenly apply pressure to low pressure and small chamber gauges. Do not exceed the safety pressure limit(18MPa). Compressed air may cause problem in explosive or corruptive environment. Do not shift the selector to vacuum mode under pressure. Do not over tighten connectors to avoid any damage. The pump could store in the dry and non-corruptive environment. Any safety problems or damages caused by incorrect operation, are beyond ConST group's responsibility. Specification Pressure range: (-0.095 to 12)MPa Temperature: (0~50)℃ Humidity: < 85%RH Adjusting fineness: 10Pa Safety pressure: < 18MPa Pressure media: Air Weight: 7.1kg Remark:If local atmosphere pressure is 100kPa, the vacuum can reach to -95kPa; If local atmosphere pressure is P, the vacuum can reach to - (95P/100)kPa. Calibration can be easy! Air routine&Accessories ConST 162 7 Table Pneumatic Pump User's Manual [Version number:1009V10] Accessories Air routine sealing ring ZL200620119357.2 ×20 3 8 plug 2 ×2 5 Configuration & Size 1 2 3 4 1 - M20×1.5 connector 2 - Pressure lever 3 - Pressure/vacuum selector (Pressure: pull it out; Vacuum: push it in.Do not shift under pressure) 4 - Selector-protector 5 - Fine adjust handles 506mm 54° (clockwise to increase pressure) 6 6 - Clean-out hole 7 - Isolating valve 178mm (isolate the calibration from pressurizing system) 5 8 - Release valve 9 8 7 450mm (clockwise to close/ anticlockwise to open) 540mm 270mm 9 - Vent hole Troubleshooting Problems Hard to use pressure lever Hard to pressurize Hard to use fine adjust Not easy to turn the fittings Solutions Causes The isolating valve is not open. Open the isolating valve. A. Release valve is not closed. Close the release valve. B. The sealing ring is broken or loosen. Replace sealing ring (PR#:ZL200620119357.2). C. P/V selector is in wrong position. Pressure: pull it out; Vacuum: push it in. D. Pipeline jamed with impurity. Open the Clean-out bolt and clean. A. The isolating valve is not closed. Close the isolating valve. B. The gauges is not tightened. Tighten the reference gauge or the gauge under test. C. The sealing ring is aged or frayed. Replace sealing ring. D. The thread surface is not smooth. Put in a Teflon seals and turn it tightly. E. The connector type is unmatched. Use the right and suitable adapter. F. The impurity blocks the air routine. Repeat pressurizing several times and then release it suddenly, make airflow to bring the impurity out. A. Too tightly turned last time! Do not apply much force to close the fittings and valves. B. The new pump is not smooth. The new pump needs time to abrade. C. The threads have no lubrication. Lubricate the thread. Basic Operation A Connection DIGITAL PRESSURE CALIBRAT OR Units SW SW V mA COM Open to atmosphere Pre-pressure Increase pressure process DIGITAL PRESSURE CALIBRATOR C Increase pressure 2 open (for precision 3 close measure) 4 turn it in the mid-position D DIGITAL PRESSURE C ALIBRATOR 2 to the desired value 1 select the pressure mode flexible hose Units Units 3 open 24V Decrease pressure process DIGITAL PRESSURE CALI BRATOR Units COM pressure transmitter pressure switch B mA ConST273 ConST273 dial gauge V 24V 0 4 Fine adjust 2 Fine adjust 1 close 1 Open it slowly to get the desired value, and close! Zeroing should be operated under this condition only. Prepare for vacuum E Vacuum process F DIGITAL PRESSURE CALI BRATOR DIGITAL PRESSURE C ALIBRATOR DIGITAL PRESSURE CALIBRA TOR Units Units Units 0.06 0.06 0.04 - 0.1 4 open MPa 0.04 0.06 真空表 真空表 0.08 0.08 .02 00.02 vacuum-pumping 0 1 to the desired value 3 operate it to get the desired value G Decrease vacuum process (for precision 2 close measure) MPa - 0.1 0.04 真空表 0.08 0.02 0 MPa - 0.1 0.02 0 2 Fine adjust 3 Fine adjust 5 close 1 1 open Open it slowly to get the desired value, and close! 2 Push in, select the vacuum mode Open to atmosphere before operation Remark: A: ConST group has made a concerted effort to provide complete and current information for the proper use of the equipment. The product specifications and other information contained this manual are subject to change without notice. B: Above pictures are just for reference. Beijing ConST Instruments Technology Inc. www . constgroup . com 8610 - 82782288