CO S M O - I N S TA L L AT I O N M A N UA L
Table 2: Determination of the permissibility of a concentric system with a roof terminal
Total number of
meters horizontal
pipe length
1
2
3
4
5
6
7
↓8
↓9
10
11
12
0
A
A
A
A
A
A
A
A
B
B
B
B
A
A
A
A
A
A
A
A
A
B
B
A
A
A
A
A
A
A
A
B
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
no bends
2 bends
Total number of meters vertical and/or sloping pipe length
0
1
2
→
3
4
English
G20/25
5
3 bends
0
A
1
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
2
3
→
4
B
5
4 bends
0
A
1
A
A
2
3
4
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
A
A
A
A
A
A
B
A
A
A
A
A
5
5 bochten
-
■ = situation is not allowed
Table 3: Conditions for the adjustment of the appliance with a roof terminal
G20/G25
Situation
Baffle
Distance of restriction in mm
A
NO
OPEN
B
YES
80
6.6 Placing the chimney breast
The appliance is designed to be mounted tightly in a new chimney breast.
In order to provide proper heat discharge, there should be sufficient space around the appliance.
The chimney breast should be ventilated sufficiently by means of ventilation holes.
Caution
- Use non combustible and heat-resistant materials for the chimney breast, including the top of the chimney breast,
the material in the chimney breast and the back wall of the chimney breast;
- Make sure that the appliance is not carrying the weight of the chimney breast when using stone-like materials;
- The ventilation holes - which should be mounted as high as possible - should have a combined passage of at least
520 cm2.
!Caution When placing the chimney breast, you should take the following into account (see fig. 2):
- the location of the control box (K): it should be placed with a distance of 850 mm to the left or to the right of the appliance - as low as possible;
- the measurements of the control box; see Placing the Control Box section 6.7;
- the location of the ventilation holes (V);
- measurement of the glass window, so it can be placed/removed after placing the chimney breast;
- the protection of the gas control and the pipes against cement and plaster.
9 GB
95902101_GB Install.indd 9
27-5-10 15:35