HCD-GN880 SECTION 5 MECHANICAL ADJUSTMENTS Precaution 1. Clean the following parts with a denatured alcohol-moistened swab: record/playback heads pinch rollers erase head rubber belts capstan idlers 2. Demagnetize the record/playback head with a head demagnetizer. 3. Do not use a magnetized screwdriver for the adjustments. 4. After the adjustments, apply suitable locking compound to the parts adjusted. 5. The adjustments should be performed with the rated power supply voltage unless otherwise noted. Torque Measurement Mode FWD FWD back tension Torque meter CQ-102C CQ-102C REV CQ-102RC REV back tension CQ-102RC FF/REW CQ-201B FWD tension CQ-403A REV tension CQ-403R Meter reading 3.06 N • m to 6.96 N • m 31 to 71 g • cm (0.43 – 0.98 oz • inch) 0.19 N • m to 0.58 N • m 2 to 6 g • cm (0.02 – 0.08 oz • inch) 3.06 N • m to 6.96 N • m 31 to 71 g • cm (0.43 – 0.98 oz • inch) 0.19 N • m to 0.58 N • m 2 to 6 g • cm (0.02 – 0.08 oz • inch) 6.96 N • m to 14.02 N • m 71 to 143 g • cm (0.98 – 1.99 oz • inch) 9.80 N • m 100 g or more (3.53 oz or more) 9.80 N • m 100 g or more (3.53 oz or more) SECTION 6 ELECTRICAL ADJUSTMENTS DECK SECTION 0 dB=0.775 V 1. Demagnetize the record/playback head with a head demagnetizer. 2. Do not use a magnetized screwdriver for the adjustments. 3. After the adjustments, apply suitable locking compound to the parts adjust. 4. The adjustments should be performed with the rated power supply voltage unless otherwise noted. 5. The adjustments should be performed in the order given in this service manual. (As a general rule, playback circuit adjustment should be completed before performing recording circuit adjustment.) 6. The adjustments should be performed for both L-CH and RCH. 7. Switches and controls should be set as follows unless otherwise specified. • Test Tape Tape P-4-A100 Signal 10 kHz, –10 dB Used for Azimuth Adjustment RECORD/PLAYBACK HEAD AZIMUTH ADJUST-MENT DECK A DECK B Note: Perform this adjustments for both decks Procedure: 1. Mode: Playback test tape P-4-A100 (10 kHz, –10 dB) MAIN board CN510 Pin 1 (L-CH) Pin 3 (R-CH) level meter set + – MAIN board CN510 Pin 2 (GND) 21