Service Manual Part ė : Installation and Maintenance 7. Notes for Installation and Maintenance Safety Precautions: Important! Please read the safety precautions carefully before installation and maintenance. The following contents are very important for installation and maintenance. Please follow the instructions below. Ɣ7KHLQVWDOODWLRQRUPDLQWHQDQFHPXVWDFFRUGZLWKWKH instructions. Ɣ&RPSO\ZLWKDOOQDWLRQDOHOHFWULFDOFRGHVDQGORFDO electrical codes. Ɣ3D\DWWHQWLRQWRWKHZDUQLQJVDQGFDXWLRQVLQWKLV manual. Ɣ$OOLQVWDOODWLRQDQGPDLQWHQDQFHVKDOOEHSHUIRUPHGE\ GLVWULEXWRURUTXDOL¿HGSHUVRQ Ɣ$OOHOHFWULFZRUNPXVWEHSHUIRUPHGE\DOLFHQVHG technician according to local regulations and the instructions given in this manual. Ɣ%HFDXWLRQGXULQJLQVWDOODWLRQDQGPDLQWHQDQFH3URKLELW incorrect operation to prevent electric shock, casualty and other accidents. Warnings Electrical Safety Precautions: 1. Cut off the power supply of air conditioner before checking and maintenance. 2. The air condition must apply specialized circuit and prohibit share the same circuit with other appliances. 3. The air conditioner should be installed in suitable location and ensure the power plug is touchable. 4. Make sure each wiring terminal is connected firmly during installation and maintenance. 5. Have the unit adequately grounded. The grounding wire can’t be used for other purposes. 6. Must apply protective accessories such as protective boards, cable-cross loop and wire clip. 7. The live wire, neutral wire and grounding wire of power supply must be corresponding to the live wire, neutral wire and grounding wire of the air conditioner. 8. The power cord and power connection wires can’t be pressed by hard objects. 9. If power cord or connection wire is broken, it must be UHSODFHGE\DTXDOL¿HGSHUVRQ Installation and Maintenance 10. If the power cord or connection wire is not long enough, please get the specialized power cord or connection wire from the manufacture or distributor. Prohibit prolong the wire by yourself. 11. For the air conditioner without plug, an air switch must be installed in the circuit. The air switch should be all-pole parting and the contact parting distance should be more than 3mm. 12. Make sure all wires and pipes are connected properly and the valves are opened before energizing. 13. Check if there is electric leakage on the unit body. If yes, please eliminate the electric leakage. 5HSODFHWKHIXVHZLWKDQHZRQHRIWKHVDPHVSHFL¿FDWLRQ if it is burnt down; don’t replace it with a cooper wire or conducting wire. 15. If the unit is to be installed in a humid place, the circuit breaker must be installed. Installation Safety Precautions: 1. Select the installation location according to the requirement of this manual.(See the requirements in installation part) 2. Handle unit transportation with care; the unit should not be carried by only one person if it is more than 20kg. :KHQ LQVWDOOLQJ WKH LQGRRU XQLW DQG RXWGRRU XQLW D VXI¿FLHQW¿[LQJEROWPXVWEHLQVWDOOHGPDNHVXUHWKHLQVWDOODWLRQ VXSSRUWLV¿UP 4. Ware safety belt if the height of working is above 2m. 5. Use equipped components or appointed components during installation. 0DNHVXUHQRIRUHLJQREMHFWVDUHOHIWLQWKHXQLWDIWHU¿Qishing installation. Refrigerant Safety Precautions: $YRLGFRQWDFWEHWZHHQUHIULJHUDQWDQG¿UHDVLWJHQHUDWHV poisonous gas; Prohibit prolong the connection pipe by welding. $SSO\VSHFL¿HGUHIULJHUDQW RQO\1HYHU KDYH LWPL[HGZLWK any other refrigerant. Never have air remain in the refrigerant line as it may lead to rupture or other hazards. 3. Make sure no refrigerant gas is leaking out when installation is completed. 4. If there is refrigerant leakage, please take sufficient measure to minimize the density of refrigerant. 5. Never touch the refrigerant piping or compressor without wearing glove to avoid scald or frostbite. ,PSURSHULQVWDOODWLRQPD\OHDGWR¿UHKD]DUGH[SORVLRQ electric shock or injury. 41 Service Manual Main Tools for Installation and Maintenance 1. Level meter, measuring tape 2. Screw driver 3. Impact drill, drill head, electric drill 42 4. Electroprobe 5. Universal meter 6. Torque wrench, open-end wrench, inner hexagon spanner 7. Electronic leakage detector 8. Vacuum pump 9. Pressure meter 10. Pipe pliers, pipe cutter 11. Pipe expander, pipe bender 12. Soldering appliance, refrigerant container Installation and Maintenance Service Manual 8. Installation At least 15cm Space to the ceiling 8.1 Installation Dimension Diagram Space to the wall Space to the wall At least 15cm At least 250cm Space to the floor m 0c 30 st lea At ac et At ot lea st he At least 50cm Sp Space to the obstruction Sp ac et ot he ob str uc tio n At least 15cm n ctio tru e ac Sp to the st a t le s ob cm 30 A wa ll 30 cm Drainage pipe n tio c tru s et he ot c pa S Installation and Maintenance ob At lea cm 00 2 st Sp At ac et lea st ot he 50 cm ob str uc tio n 43 Service Manual Installation Procedures Start installation Preparation before installation Read the requirements for electric connection select installation location Select indoor unit installation location Prepare tools Select outdoor unit installation location Install the support of outdoor unit (select it according to the actual situation) Install wall-mounting frame, drill wall holes Connect pipes of indoor unit and drainage pipe Fix outdoor unit Connect wires of indoor unit Install drainage joint of outdoor unit (only for cooling and heating unit) Bind up pipes and hang the indoor unit Make the bound pipes pass through the wall hole and then connect outdoor unit Connect pipes of outdoor unit Connect wires of outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation Note: this flow is only for reference; please find the more detailed installation steps in this section. 44 Installation and Maintenance Service Manual 8.2 Installation Parts-Checking No. 1 2 Name ,QGRRUXQLW 2XWGRRUXQLW No. 8 9 3 Connection pipe 10 4 Drainage pipe :DOOPRXQWLQJ frame Connecting cable(power cord) Wall pipe 11 5 6 7 12 13 Name 6HDOLQJJXP Wrapping tape 6XSSRUWRIRXWGRRU XQLW )L[LQJVFUHZ 'UDLQDJHSOXJFRROLQJ DQGKHDWLQJXQLW 2ZQHU¶VPDQXDO remote controller Note: 3OHDVHFRQWDFWWKHORFDODJHQWIRULQVWDOODWLRQ 'RQ WXVHXQTXDOL¿HGSRZHUFRUG 8.3 Selection of Installation Location 1. Basic Requirement: ,QVWDOOLQJWKHXQLWLQWKHIROORZLQJSODFHVPD\FDXVH PDOIXQFWLRQ,ILWLVXQDYRLGDEOHSOHDVHFRQVXOWWKHORFDOGHDOHU 7KHSODFHZLWKVWURQJKHDWVRXUFHVYDSRUVÀDPPDEOHRU H[SORVLYHJDVRUYRODWLOHREMHFWVVSUHDGLQWKHDLU 7KH SODFH ZLWK KLJKIUHTXHQF\ GHYLFHV VXFK DV ZHOGLQJ PDFKLQHPHGLFDOHTXLSPHQW 7KHSODFHQHDUFRDVWDUHD 7KHSODFHZLWKRLORUIXPHVLQWKHDLU 7KHSODFHZLWKVXOIXUHWHGJDV 2WKHUSODFHVZLWKVSHFLDOFLUFXPVWDQFHV 2. Indoor Unit: 7KHUHVKRXOGEHQRREVWUXFWLRQQHDUDLULQOHWDQGDLURXWOHW 6HOHFW D ORFDWLRQ ZKHUH WKH FRQGHQVDWLRQ ZDWHU FDQ EH GLVSHUVHGHDVLO\DQGZRQ WDIIHFWRWKHUSHRSOH 6HOHFW D ORFDWLRQ ZKLFK LV FRQYHQLHQW WR FRQQHFW WKH RXWGRRUXQLWDQGQHDUWKHSRZHUVRFNHW 6HOHFWDORFDWLRQZKLFKLVRXWRIUHDFKIRUFKLOGUHQ 7KH ORFDWLRQ VKRXOG EH DEOH WR ZLWKVWDQG WKH ZHLJKW RI LQGRRUXQLWDQGZRQ WLQFUHDVHQRLVHDQGYLEUDWLRQ 7KHDSSOLDQFHPXVWEHLQVWDOOHGPDERYHÀRRU 'RQ W LQVWDOO WKH LQGRRU XQLW ULJKW DERYH WKH HOHFWULF appliance. 7KHDSSOLDQFHVKDOOQRWEHLQVWDOOHGLQWKHODXQGU\ 3. Outdoor Unit: 6HOHFWDORFDWLRQZKHUHWKHQRLVHDQGRXWÀRZDLUHPLWWHGE\ WKHRXWGRRUXQLWZLOOQRWDIIHFWQHLJKERUKRRG 7KHORFDWLRQVKRXOGEHZHOOYHQWLODWHGDQGGU\LQZKLFKWKH RXWGRRU XQLW ZRQ W EH H[SRVHG GLUHFWO\ WR VXQOLJKW RU VWURQJ wind. 7KH ORFDWLRQ VKRXOG EH DEOH WR ZLWKVWDQG WKH ZHLJKW RI RXWGRRUXQLW 0DNHVXUHWKDWWKHLQVWDOODWLRQIROORZVWKHUHTXLUHPHQWRI installation dimension diagram. 6HOHFWDORFDWLRQZKLFKLVRXWRIUHDFKIRUFKLOGUHQDQGIDU DZD\ IURP DQLPDOV RU SODQWV,I LW LV XQDYRLGDEOH SOHDVH DGG IHQFHIRUVDIHW\SXUSRVH Installation and Maintenance 8.4 Electric Connection Requirement 1. Safety Precaution 0XVWIROORZWKHHOHFWULFVDIHW\UHJXODWLRQVZKHQ LQVWDOOLQJ WKHXQLW $FFRUGLQJ WR WKH ORFDO VDIHW\ UHJXODWLRQV XVH TXDOLILHG SRZHUVXSSO\FLUFXLWDQGDLUVZLWFK 0DNHVXUHWKHSRZHUVXSSO\PDWFKHVZLWKWKHUHTXLUHPHQW RI DLU FRQGLWLRQHU 8QVWDEOH SRZHU VXSSO\ RU LQFRUUHFW ZLULQJ PD\UHVXOWLQHOHFWULFVKRFN¿UHKD]DUGRUPDOIXQFWLRQ3OHDVH LQVWDOO SURSHU SRZHU VXSSO\ FDEOHV EHIRUH XVLQJ WKH DLU conditioner. Air-conditioner 28K 18/24K $LUVZLWFKFDSDFLW\ 25A 16A 3URSHUO\FRQQHFWWKHOLYHZLUHQHXWUDOZLUHDQGJURXQGLQJ ZLUHRISRZHUVRFNHW %HVXUHWRFXWRIIWKHSRZHUVXSSO\EHIRUHSURFHHGLQJDQ\ ZRUNUHODWHGWRHOHFWULFLW\DQGVDIHW\ 'RQRWSXWWKURXJKWKHSRZHUEHIRUH¿QLVKLQJLQVWDOODWLRQ )RU DSSOLDQFHV ZLWK W\SH < DWWDFKPHQWWKH LQVWUXFWLRQV VKDOOFRQWDLQWKHVXEVWDQFHRIWKHIROORZLQJ,IWKHVXSSO\FRUGLV GDPDJHGLWPXVWEHUHSODFHGE\WKHPDQXIDFWXUHULWVVHUYLFH DJHQWRUVLPLODUO\TXDOL¿HGSHUVRQVLQRUGHUWRDYRLGDKD]DUG 7KH WHPSHUDWXUH RI UHIULJHUDQWFLUFXLWZLOOEHKLJK SOHDVH NHHSWKHLQWHUFRQQHFWLRQFDEOHDZD\IURPWKHFRSSHUWXEH 2. Grounding Requirement: 7KHDLUFRQGLWLRQHULV¿UVWFODVVHOHFWULFDSSOLDQFH,WPXVW EH SURSHUO\ JURXQGLQJ ZLWK VSHFLDOL]HG JURXQGLQJ GHYLFH E\ D SURIHVVLRQDO 3OHDVH PDNH VXUH LW LV DOZD\V JURXQGHG HIIHFWLYHO\RWKHUZLVHLWPD\FDXVHHOHFWULFVKRFN 7KH\HOORZJUHHQZLUHLQDLUFRQGLWLRQHULVJURXQGLQJZLUH ZKLFKFDQ WEHXVHGIRURWKHUSXUSRVHV 7KH JURXQGLQJ UHVLVWDQFH VKRXOG FRPSO\ ZLWK QDWLRQDO HOHFWULFVDIHW\UHJXODWLRQV 7KH DSSOLDQFH PXVW EH SRVLWLRQHG VR WKDW WKH SOXJ LV accessible. $QDOOSROHGLVFRQQHFWLRQVZLWFKKDYLQJDFRQWDFWVHSDUDWLRQ RIDWOHDVWPPLQDOOSROHVVKRXOGEHFRQQHFWHGLQ¿[HGZLULQJ ,QFOXGLQJDQDLUVZLWFKZLWKVXLWDEOHFDSDFLW\SOHDVHQRWH WKH IROORZLQJ WDEOH$LU VZLWFK VKRXOG EH LQFOXGHG PDJQHW EXFNOH DQG KHDWLQJ EXFNOH IXQFWLRQ LW FDQ SURWHFW WKH FLUFXLW VKRUWDQGRYHUORDG&DXWLRQSOHDVHGRQRWXVHWKHIXVHRQO\ IRUSURWHFWWKHFLUFXLW 8.5 Installation of Indoor Unit 1. Choosing Installation Iocation 5HFRPPHQG WKH LQVWDOODWLRQ ORFDWLRQ WR WKH FOLHQW DQG WKHQ FRQ¿UPLWZLWKWKHFOLHQW 2. Install Wall-mounting Frame +DQJ WKH ZDOOPRXQWLQJ IUDPH RQ WKH ZDOO DGMXVW LW LQ KRUL]RQWDOSRVLWLRQZLWKWKHOHYHOPHWHUDQGWKHQSRLQWRXWWKH VFUHZ¿[LQJKROHVRQWKHZDOO 'ULOOWKHVFUHZ¿[LQJKROHVRQWKHZDOOZLWKLPSDFWGULOOWKH VSHFLILFDWLRQ RI GULOO KHDG VKRXOG EH WKH VDPH DV WKH SODVWLF H[SDQVLRQSDUWLFOHDQGWKHQ¿OOWKHSODVWLFH[SDQVLRQSDUWLFOHV 45 Service Manual LQWKHKROHV )L[WKHZDOOPRXQWLQJIUDPHRQWKHZDOOZLWKWDSSLQJVFUHZV 67;7$DQGWKHQFKHFNLIWKHIUDPHLV¿UPO\LQVWDOOHGE\ SXOOLQJ WKH IUDPH ,I WKH SODVWLF H[SDQVLRQ SDUWLFOH LV ORRVH SOHDVHGULOODQRWKHU¿[LQJKROHQHDUE\ 3. Install Wall-mounting Frame &KRRVHWKHSRVLWLRQRISLSLQJKROHDFFRUGLQJWRWKHGLUHFWLRQ RI RXWOHW SLSH7KH SRVLWLRQ RI SLSLQJ KROH VKRXOG EH D OLWWOH ORZHUWKDQWKHZDOOPRXQWHGIUDPH$VVKRZLQ)LJ Wall Wall Level meter Mark in the middle of it Space to the wall above 150mm Space to the wall above 150mm Left Φ55/70mm Rear piping hole 5. Connect the Pipe of Indoor Unit $LPWKHSLSHMRLQWDWWKHFRUUHVSRQGLQJEHOOPRXWK$VVKRZ LQ)LJ 3UHWLJKWHQLQJWKHXQLRQQXWZLWKKDQG $GMXVWWKHWRUTXHIRUFHE\UHIHUULQJWRWKHIROORZLQJVKHHW 3ODFH WKH RSHQHQG ZUHQFK RQ WKH SLSH MRLQW DQG SODFH WKH WRUTXH ZUHQFK RQ WKH XQLRQ QXW7LJKWHQ WKH XQLRQ QXW ZLWK WRUTXHZUHQFK$VVKRZLQ)LJ :UDS WKH LQGRRU SLSH DQG MRLQW RI FRQQHFWLRQ SLSH ZLWK LQVXODWLQJSLSHDQGWKHQZUDSLWZLWKWDSH$VVKRZLQ)LJ Open-end wrench Union nut Pipe joint Union nut Right Φ55/70mm Rear piping hole )LJ Pipe )LJ Indoor pipe 2SHQDSLSLQJKROHZLWKWKHGLDPHWHURIĭPPRQWKH VHOHFWHG RXWOHW SLSH SRVLWLRQ,Q RUGHU WR GUDLQ VPRRWKO\ VODQW WKH SLSLQJ KROH RQ WKH ZDOO VOLJKWO\ GRZQZDUG WR WKH RXWGRRU VLGHZLWKWKHJUDGLHQWRI$VVKRZLQ)LJ Indoor Pipe Torque wrench )LJ Insulating pipe )LJ Outdoor 5HIHUWRWKHIROORZLQJWDEOHIRUZUHQFKPRPHQWRIIRUFH: +H[QXWGLDPHWHUPP ĭ ĭ ĭ ĭ ĭ Φ55/Φ70mm 5-10° )LJ Note: 3D\ DWWHQWLRQ WR GXVW SUHYHQWLRQ DQG WDNH UHOHYDQW VDIHW\ PHDVXUHVZKHQRSHQLQJWKHKROH 7KHSODVWLFH[SDQVLRQSDUWLFOHVDUHQRWSURYLGHGDQGVKRXOG EHERXJKWORFDOO\ . 7LJKWHQLQJWRUTXH1P 15~20 30~40 45~55 60~65 70~75 6. Install Drain Hose &RQQHFWWKHGUDLQKRVHWRWKHRXWOHWSLSHRILQGRRUXQLW$V VKRZLQ)LJ %LQGWKHMRLQWZLWKWDSH$VVKRZLQ)LJ 4. Outlet Pipe 7KHSLSHFDQEHOHGRXWLQWKHGLUHFWLRQRIULJKWUHDUULJKW OHIWRUUHDUOHIW$VVKRZLQ)LJ :KHQVHOHFWLQJOHDGLQJRXWWKHSLSHIURPOHIWRUULJKWSOHDVH FXWRIIWKHFRUUHVSRQGLQJKROHRQWKHERWWRPFDVH$VVKRZLQ )LJ Drain hose Outlet pipe Drain hose Tape )LJ )LJ Outlet pipe Note: Left )LJ Left Rear right Right Cut off the hole 46 Right Rear left $GG LQVXODWLQJ SLSH LQ WKH LQGRRU GUDLQ KRVH LQ RUGHU WR SUHYHQWFRQGHQVDWLRQ 7KHSODVWLFH[SDQVLRQSDUWLFOHVDUHQRWSURYLGHG$VVKRZ LQ)LJ Drain hose )LJ Insulating pipe )LJ Installation and Maintenance Service Manual 7. Connect Wire of Indoor Unit 8. Bind up Pipe 2SHQWKHSDQHOUHPRYHWKHVFUHZRQWKHZLULQJFRYHUDQG WKHQWDNHGRZQWKHFRYHU$VVKRZLQ)LJ %LQG XS WKH FRQQHFWLRQ SLSH SRZHU FRUG DQG GUDLQ KRVH ZLWKWKHEDQG$VVKRZLQ)LJ 5HVHUYH D FHUWDLQ OHQJWK RI GUDLQ KRVH DQG SRZHU FRUG IRULQVWDOODWLRQZKHQELQGLQJWKHP:KHQELQGLQJWRDFHUWDLQ GHJUHHVHSDUDWHWKHLQGRRUSRZHUDQGWKHQVHSDUDWHWKHGUDLQ KRVH$VVKRZLQ)LJ %LQGWKHPHYHQO\ 7KHOLTXLGSLSHDQGJDVSLSHVKRXOGEHERXQGVHSDUDWHO\DW WKHHQG Panel )LJ Screw Wiring cover (2) Make the power connection wire go through the cable-cross hole at the back of indoor unit and then pull it out from the front side.(As show in Fig.12) Indoor and outdoor power cord Indoor unit Gas pipe )LJ Cable-cross hole Liquid pipe Band Drain hose Power connection wire Connection pipe Drain hose 5HPRYHWKHZLUHFOLSFRQQHFWWKHSRZHUFRQQHFWLRQZLUH WRWKHZLULQJWHUPLQDODFFRUGLQJWRWKHFRORUWLJKWHQWKHVFUHZ DQGWKHQ¿[WKHSRZHUFRQQHFWLRQZLUHZLWKZLUHFOLS$VVKRZ LQ)LJ Band )LJ Indoor power cord 2 blue 3 Note: 7KH SRZHU FRUG DQG FRQWURO ZLUH FDQ W EH FURVVHG RU winding. 7KHGUDLQKRVHVKRXOGEHERXQGDWWKHERWWRP black brown yellowgreen Connect to outdoor unit 9. Hang the Indoor Unit Wiring board N(1) 2 3XWWKHERXQGSLSHVLQWKHZDOOSLSHDQGWKHQPDNHWKHP SDVVWKURXJKWKHZDOOKROH +DQJWKHLQGRRUXQLWRQWKHZDOOPRXQWLQJIUDPH 6WXIIWKHJDSEHWZHHQSLSHVDQGZDOOKROHZLWKVHDOLQJJXP )L[WKHZDOOSLSH$VVKRZLQ)LJ &KHFNLIWKHLQGRRUXQLWLVLQVWDOOHG¿UPO\DQGFORVHGWRWKH ZDOO$VVKRZLQ)LJ 3 Wire clip )LJ 3XWZLULQJFRYHUEDFNDQGWKHQWLJKWHQWKHVFUHZ &ORVHWKHSDQHO Note: $OO ZLUHV RI LQGRRU XQLW DQG RXWGRRU XQLW VKRXOG EH connected by a professional. ,IWKHOHQJWKRISRZHUFRQQHFWLRQZLUHLVLQVXI¿FLHQWSOHDVH FRQWDFWWKHVXSSOLHUIRUDQHZRQH$YRLGH[WHQGLQJWKHZLUHE\ \RXUVHOI )RU WKH DLU FRQGLWLRQHU ZLWK SOXJ WKH SOXJ VKRXOG EH UHDFKDEOHDIWHU¿QLVKLQJLQVWDOODWLRQ )RUWKHDLUFRQGLWLRQHUZLWKRXWSOXJDQDLUVZLWFKPXVWEH LQVWDOOHG LQ WKH OLQH7KH DLU VZLWFK VKRXOG EH DOOSROH SDUWLQJ DQGWKHFRQWDFWSDUWLQJGLVWDQFHVKRXOGEHPRUHWKDQPP Installation and Maintenance Indoor Wall pipe Outdoor )LJ Sealing gum Upper hook )LJ Lower hook of wall-mounting frame Note: 'RQRWEHQGWKHGUDLQKRVHWRRH[FHVVLYHO\LQRUGHUWRSUHYHQW EORFNLQJ 47 Service Manual 5HIHUWRWKHIROORZLQJWDEOHIRUZUHQFKPRPHQWRIIRUFH: 8.6 Installation of Outdoor Unit 1. Fix the Support of Outdoor Unit(select it according to the actual installation situation) 6HOHFWLQVWDOODWLRQORFDWLRQDFFRUGLQJWRWKHKRXVHVWUXFWXUH )L[WKHVXSSRUWRIRXWGRRUXQLWRQWKHVHOHFWHGORFDWLRQZLWK expansion screws. Note: 7DNH VXIILFLHQW SURWHFWLYH PHDVXUHV ZKHQ LQVWDOOLQJ WKH RXWGRRUXQLW 0DNHVXUHWKHVXSSRUWFDQZLWKVWDQGDWOHDVWIRXUWLPHVWKH XQLWZHLJKW 7KHRXWGRRUXQLWVKRXOGEHLQVWDOOHGDWOHDVWFPDERYHWKH ÀRRULQRUGHUWRLQVWDOOGUDLQMRLQW$VVKRZLQ)LJ )RU WKH XQLW ZLWK FRROLQJ FDSDFLW\ RI :a: H[SDQVLRQVFUHZVDUHQHHGHGIRUWKHXQLWZLWKFRROLQJFDSDFLW\ RI :a: H[SDQVLRQ VFUHZV DUH QHHGHG IRU WKH XQLWZLWKFRROLQJFDSDFLW\RI:a:H[SDQVLRQ screws are needed. . 7LJKWHQLQJWRUTXH1P 15~20 30~40 45~55 60~65 70~75 +H[QXWGLDPHWHUPP ĭ ĭ ĭ ĭ ĭ 5. Connect Outdoor Electric Wire 5HPRYH WKH ZLUH FOLS FRQQHFW WKH SRZHU FRQQHFWLRQ ZLUH DQGSRZHUFRUGWRWKHZLULQJWHUPLQDODFFRUGLQJWRWKHFRORU¿[ WKHPZLWKVFUHZV$VVKRZLQ)LJ )LJ N Handle N(1) DRED POWER LN Drain vent Chassis Outdoor drain joint Drain hose At least 3cm above the floor 2 3 blue black brown L L N yellow-green blue brown Indoor Unit Note: The wiring connect is for reference only, please refer to the actual one. )L[WKHSRZHUFRQQHFWLRQZLUHDQGSRZHUFRUGZLWKZLUHFOLS )LJ )LJ 2. Install Drain Joint(Only for Cooling and Heating Unit) &RQQHFWWKHRXWGRRUGUDLQMRLQWLQWRWKHKROHRQWKHFKDVVLV &RQQHFW WKH GUDLQ KRVH LQWR WKH GUDLQ YHQW$V VKRZ LQ )LJ 3. Fix Outdoor Unit 3ODFHWKHRXWGRRUXQLWRQWKHVXSSRUW )L[ WKH IRRW KROHV RI RXWGRRU XQLW ZLWK EROWV$V VKRZ LQ )LJ Foot holes Handle Screw Note: $IWHU WLJKWHQLQJ WKH VFUHZ SXOO WKH SRZHU FRUG VOLJKWO\ WR FKHFNLILWLV¿UP 1HYHUFXWWKHSRZHUFRQQHFWLRQZLUHWRSURORQJRUVKRUWHQ WKHGLVWDQFH 6. Neaten the Pipes 7KHSLSHVVKRXOGEHSODFHGDORQJWKHZDOOEHQWUHDVRQDEO\ DQGKLGGHQSRVVLEO\0LQVHPLGLDPHWHURIEHQGLQJWKHSLSHLV 10cm. ,IWKHRXWGRRUXQLWLVKLJKHUWKDQWKHZDOOKROH\RXPXVWVHW D8VKDSHGFXUYHLQWKHSLSHEHIRUHSLSHJRHVLQWRWKHURRP LQRUGHUWRSUHYHQWUDLQIURPJHWWLQJLQWRWKHURRP$VVKRZLQ )LJ Foot holes )LJ The drain hos can't raise upwards )LJ 4. Connect Indoor and Outdoor Pipes 5HPRYHWKHVFUHZRQWKHULJKWKDQGOHRIRXWGRRUXQLWDQG WKHQUHPRYHWKHKDQGOH$VVKRZLQ)LJ 5HPRYHWKHVFUHZFDSRIYDOYHDQGDLPWKHSLSHMRLQWDWWKH EHOOPRXWKRISLSH$VVKRZLQ)LJ Wall )LJ U-shaped curve Liquid pipe Liquid valve Pipe joint )LJ gas pipe gas valve Union nut )LJ 3UHWLJKWHQLQJWKHXQLRQQXWZLWKKDQG 7LJKWHQWKHXQLRQQXWZLWKWRUTXHZUHQFK 48 Drain hose Note: 7KHWKURXJKZDOOKHLJKWRIGUDLQKRVHVKRXOGQ WEHKLJKHU WKDQWKHRXWOHWSLSHKROHRILQGRRUXQLW$VVKRZLQ)LJ 6ODQW WKH GUDLQ KRVH VOLJKWO\ GRZQZDUGV7KH GUDLQ KRVH FDQ WEHFXUYHGUDLVHGDQGÀXFWXDQWHWF$VVKRZLQ)LJ Installation and Maintenance Service Manual 7KHZDWHURXWOHWFDQ WEHSODFHGLQZDWHULQRUGHUWRGUDLQ VPRRWKO\$VVKRZLQ)LJ 8.8 Check after Installation and Test Operation 1. Check after Installation &KHFN DFFRUGLQJ WR WKH IROORZLQJ UHTXLUHPHQW DIWHU ILQLVKLQJ installation. The drain hose can't be fluctuant NO. The drain hose can't be fluctuant 1 The water outlet can't be placed in water The water outlet can't be fluctuant 2 )LJ 3 )LJ 4 8.7 Vacuum Pumping and Leak Detection 1. Use Vacuum Pump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iquid valve Piezometer Lo Hi Gas valve Refrigerant charging vent Valve cap Nut of refrigerant Charging vent Vacuum pump Inner hexagon spanner )LJ ,WHPVWREHFKHFNHG +DVWKHXQLWEHHQ LQVWDOOHG¿UPO\" +DYH\RXGRQHWKH UHIULJHUDQWOHDNDJHWHVW" ,VKHDWLQVXODWLRQRI SLSHOLQHVXI¿FLHQW" ,VZDWHUGUDLQHGZHOO" 3RVVLEOHPDOIXQFWLRQ 7KHXQLWPD\GURSVKDNHRU emit noise. ,WPD\FDXVHLQVXI¿FLHQWFRROLQJ KHDWLQJFDSDFLW\ ,WPD\FDXVHFRQGHQVDWLRQDQG water dripping. ,WPD\FDXVHFRQGHQVDWLRQDQG water dripping. ,VWKHYROWDJHRISRZHU VXSSO\DFFRUGLQJWRWKH ,WPD\FDXVHPDOIXQFWLRQRU 5 YROWDJHPDUNHGRQWKH GDPDJHWKHSDUWV QDPHSODWH" Is electric wiring and ,WPD\FDXVHPDOIXQFWLRQRU 6 pipeline installed GDPDJHWKHSDUWV FRUUHFWO\" ,VWKHXQLWJURXQGHG ,WPD\FDXVHHOHFWULFOHDNDJH 7 VHFXUHO\" 'RHVWKHSRZHUFRUG ,WPD\FDXVHPDOIXQFWLRQRU 8 IROORZWKHVSHFL¿FDWLRQ" GDPDJHWKHSDUWV ,VWKHUHDQ\REVWUXFWLRQ ,WPD\FDXVHLQVXI¿FLHQWFRROLQJ 9 LQDLULQOHWDQGDLURXWOHW" KHDWLQJ 7KHGXVWDQG ,WPD\FDXVHPDOIXQFWLRQRU VXQGULHVFDXVHG 10 GDPDJLQJWKHSDUWV GXULQJLQVWDOODWLRQDUH UHPRYHG" 7KHJDVYDOYHDQGOLTXLG ,WPD\FDXVHLQVXI¿FLHQWFRROLQJ 11 YDOYHRIFRQQHFWLRQSLSH KHDWLQJFDSDFLW\ DUHRSHQFRPSOHWHO\" 2. Test Operation (1) Preparation of test operation Ɣ7KHFOLHQWDSSURYHVWKHDLUFRQGLWLRQHULQVWDOODWLRQ Ɣ6SHFLI\WKHLPSRUWDQWQRWHVIRUDLUFRQGLWLRQHUWRWKHFOLHQW 0HWKRGRIWHVWRSHUDWLRQ Ɣ3XWWKURXJKWKHSRZHUSUHVV212))EXWWRQRQWKHUHPRWH controller to start operation. Ɣ3UHVV02'(EXWWRQWRVHOHFW$872&22/'5<)$1DQG +($7WRFKHFNZKHWKHUWKHRSHUDWLRQLVQRUPDORUQRW Ɣ,IWKHDPELHQWWHPSHUDWXUHLVORZHUWKDQć WKHDLU FRQGLWLRQHUFDQ¶WVWDUWFRROLQJ Close Open 2. Leakage Detection :LWKOHDNDJHGHWHFWRU &KHFNLIWKHUHLVOHDNDJHZLWKOHDNDJHGHWHFWRU :LWKVRDSZDWHU ,IOHDNDJHGHWHFWRULVQRWDYDLODEOHSOHDVHXVHVRDSZDWHUIRU OHDNDJHGHWHFWLRQ$SSO\VRDSZDWHUDWWKHVXVSHFWHGSRVLWLRQ DQG NHHS WKH VRDS ZDWHU IRU PRUH WKDQ PLQ ,I WKHUH DUH DLU EXEEOHVFRPLQJRXWRIWKLVSRVLWLRQWKHUH VDOHDNDJH Installation and Maintenance 49