Transcript
Configuration Setup 4.2 15 QUICK SETTING OF THE REEVING If, during the crane operation, the number of reeving is modified, the LMI system has to be adjusted to this modification. The input of the reeving can be carried out directly without having to go through the whole LMI programming procedure again: 9 Call LMI Programming Procedure. Directly call function "Quick Setting of the Reevings". Note: The direct call is impossible, if the system has been turned off for more than 2 hours. input of reeving: increase reeving decrease reeving confirm reeving Confirm modification. (select again the function upon faulty input) Note: If a configuration is selected which is not available on the present crane, the system will not accept the selection and the display will indicate the error code E04. © Hirschmann Rev. E 11/12/08 190147_E