Download View Online

Transcript
P R E - O P E R AT I O N
DRAWBAR CONNECTIONS
The standard drawbar connections are as
shown in the pictures below . It is important
that the dielectric grease (supplied with
each sprayer) is applied to electrical
connections prior to connection . This
assists with lubrication and prevention of
corrosion on these connections .
Raven SCS440/450 male & female connectors
(For connections applicable for Raven
SCS4070 controllers, joystick control and/
or direct chemical injection please refer to
appropriate sections at rear of this manual . )
Tail light connection
Raven SCS4400 male & female connectors
Hydraulic hose connections
Raven male and female speed sensor connections
Male and female Deutsch connections
Safety chains
MOUNTING THE CONSOLE/S
The mounting of the consoles within the
cabin of your tractor is a critical part of
the set up process . It is important that the
consoles are mounted in the cabin in such
a way that it cannot cause harm to the
operator under any circumstance while also
being mounted in a user friendly way .
When the sprayer is removed from the
tractor, and the consoles are to remain fitted,
please ensure that all console’s remain firmly
mounted and cannot become a projectile .
For specific information on mounting
the consoles, please refer to the Raven
installation and service manual supplied .
Example of consoles securely mounted in cabin
PRAIRIE EF & ADVANCE EF OPERATORS MANUAL
4-5