SERVICING TURN OFF all power source switches. 2.1.10 Removing ISPM and ACT Module Do not touch the electrical parts when LED201 (Red) on the ISPM is lit to prevent from an electrical shock. (1) Remove the service cover according to the item 2.1.1 “Removing Service Cover”. (2) Remove the three (3) screws fixing the electrical box and turn the power plate toward the front side. NOTE: Check to ensure that LED201 (Red) is OFF when turning the power plate. Tool Phillips Screwdriver, Spanner RAS-3HVRG and 4HVRG RAS-5HVRG ISPM ISPM LED201 (Red) LED201 (Red) Fuse Act Module Capacitor Noise Filter Power Plate Reactor Capacitor Magnetic Contactor Power Plate Reactor Magnetic Contactor NOTES: 1. Identify terminal Nos. with the mark band Nos. when reassembling. If incorrectly connected, malfunction or damage to the electrical parts will occur. 2. When changing the PCB, ensure to set all the dip switches to the same configuration as the original. 2-9