Download sa-wm500 service manual

Transcript
SA-WM500
Ver 1.1 2003.06
SECTION 2
DIAGRAMS
THIS NOTE IS COMMON FOR PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS.
(In addition to this, the necessary note is printed in each block.)
For Schematic Diagrams.
Note:
For Printed Wiring Boards.
Note :
• All capacitors are in µF unless otherwise noted. pF: µµF 50 WV or
less are not indicated except for electrolytics and tantalums.
• All resistors are in Ω and 1/4 W or less unless otherwise specified.
• C : panel designation.
• X : parts extracted from the component side.
• x : parts extracted from the conductor side.
: Pattern from the side which enables seeing.
•
Note:
The components identified by mark 0 or dotted
line with mark 0 are critical for safety.
Replace only with part
number specified.
Note:
Les composants identifiés par
une marque 0 sont critiques
pour la sécurité.
Ne les remplacer que par une
piéce portant le numéro
spécifié.
A : B+ Line.
B : B– Line.
Voltages are dc with respect to ground under no-signal conditions.
no mark : Power on
Voltages are taken with a VOM (Input impedance 10 MΩ).
Voltage variations may be noted due to normal production tolerances.
• Signal path.
F : AUDIO
• Abbreviation
CND : Canadian model
MY
: Malaysia model
SP
: Singapore model
AUS : Australian model
TW : Taiwan model
•
•
•
•
•
2-1. CIRCUIT BOARDS LOCATION
CONTROL board
MAIN board
POWER AMP board
POWER SUPPLY board
LED board
POWER SWITCH board
4