Download Cellesse HP 5230 Beige / Brown HP 5230 Beige / Green
Transcript
Cellesse HP 5230 Beige / Brown HP 5230 Beige / Green Philips Domestic Appliances and Personal Care Service manual 4822 729 21748 is herewith cancelled PRODUCT INFORMATION Introduction Type appliance : 12 V adapter from mains (AC/DC) Voltage (mains) : 220-240 V, 50/60 Hz 110-127 V, 50/60 Hz Motor : DC type Max. powerconsumption : 8 watts Under pressure : 5 steps from 80 mbar to 250 mbar Length cord : 2.5 m The Cellesse is a special massage system, designed to help reduce or prevent the unsightly appearance of cellulite. Cellulite is the increased visibility of lumpy fat deposits through the surface of the skin. A common used description is ‘orange peel skin’ because of its unique pitted, lumpy appearance. Cellulite should not be confused with “cellulitis”, which is a medical term linked to bacterial infection of the skin. Cellulite can be reduced with the help of this product. It can never be completely eliminated and will return when neglected. A maximum reduction of the Cellulite layer by 55 % can be reached after 3 months, if the appliance is used 3 times a week for 15 mins. on each leg. The Cellesse does not reduce the fat in the fat layer. Note: Product meets the requirements regarding interference suppression on radio and TV. Published by Philips Domestic Appliances and Personal Care 4822 729 22124 99/02 PCS 101 214 Printed in the Netherlands © Copyright reserved Subject to modification FUNCTIONAL DESCRIPTION OF THE HP5230 CELLESSE Cleaning the rollers Function of the Cellesse The product is connected to the mains and the ON/OFF switch ( A ) is set to level 1 - 5. The pump ( B ) starts to function. The pump ( B ) only starts to function if the appliance is in a proper contact with the skin so a vacuum of at least 80 mbar can be reached. Once a vacuum of 80 mbar is reached, the electronic suppression switch ( C ) switches on the motor ( D ) of the massage rolls ( E ). To avoid a painful sucking in of the skin, the vacuum stop buttons ( F ) can be operated so that the vacuum is eliminated. The Cellesse only functions properly if the product is put properly on the skin so that the pump can build up a vacuum in the sucking area.( G ) To clean the rollers select Level 1 Fig. 1 Cover the suction opening with your thumb so the rollers start to rotate. Cleaning and Maintenance Never immerse the appliance in water nor rinse it. For the best results, keep the Cellesse clean at all times, using a damp cloth and a spot of detergent, if necessary. Do not use alcohol, acetone, gasoline, abrasives, scourers and so on for cleaning the appliance. When cleaning, special attention should be paid to the rollers on the underside. Fig. 2 Wipe the rollers clean with a damp cloth. Fig. 3 OLD VACU-stop Button W3 red F On/off Switch + Suppression Switch Level 1-5 C1 A R6 Q1 not on PCB D1 R2 R31 A2 R3 P W6 red W4 red C2 R1 R5 R25 M M1 W5 blue A3 R24 W7 blue Q3 R4 Q21 M1 = Motor rolls R22 M2 = Pump R30 Sleeve 105 R27 A1 P-JACK Q20a C R26 8 R29 3 1 W1 blue 7 2 R32 R28 Q20b C23 C24 C20 R21 C21 D20 R20 6 5 4 DAP0306 Sleeves Switches on the motor D automatically at 80 mBar underpressure M2 Q2 W2 red Pump B M Q22 Sleeve 104 El. Suppression Switch D3 NEW +13V TP6 not on W4 PCB red Sucking Area G not on W1_1 PCB C3 R1 TP11 not on W5 PCB red Q1 A3 R2 red W3 Rolls E R3 M W1_2 TP5 SOCKET-PCB A4 TP7 LEDPCB W1_2 W9_1 P A3 D3 M2 blue blue W6 W8 A5 TP12 TP14 TP9 TP2 W1_1 M TP8 TP3 TP1 M1 not on W3_1 PCB TP4 A1 P-JACK TP13 not on W7 PCB red R4 W3_2 TP15 Q2 TP10 W9_2 C4 R5 DAP0777 PCS 101 215 EXPLODED VIEW + PARTS LIST T 101 7 103 13 A 1 1 2 6 g D 10 A 102 104 5 8 B D B C C 9 12 105 4 11 PARTS LIST Pos Descprition 1 2 4 5 6 7 8 9 10 11 12 set housing parts, consisting of items 101, 102 and 2 (3x) screw power unit pump vacuum control unit - on/off switch vacuum stop p.c.b. set tubes ( item 104 + 105 ) decorative ring filter adapter EURO 220-240 V adapter UK 220-240 V Service code Beige/Brown Beige/Green Pos Descprition 4822 310 10948 4822 310 11359 12 4822 502 14427 4822 310 10949 4822 310 10951 4822 310 10952 4822 502 14427 4822 310 11361 4822 310 11362 4822 310 11363 4822 310 10953 4822 310 10954 4822 310 10955 4822 466 11484 4822 480 10164 4822 219 10047 4822 219 10202 4822 310 11364 4822 310 11365 4822 310 11366 4822 310 12242 4822 480 10272 4822 219 10618 4822 219 10619 13 adapter adapter adapter adapter adapter adapter adapter adapter adapter pouch USA JPN Korea Australia Brazil PRC CND Mexico Argentina Service code Beige/Brown Beige/Green 110-127 V 100 V 220 V 240 V 115 - 220 V 220 V 110-127 V 110-127 V 240 V Directions for use F, D, UK, NL, I Directions for use E, P, TR, Gr Directions for use DK, S, N, SF Parts with numbers from 100 and higher cannot be ordered separately 4822 219 10058 4822 219 10059 4822 219 10167 4822 219 10174 4822 219 10277 4822 219 10338 4822 219 10069 4822 219 10455 4822 600 10663 4822 219 10621 4822 219 10622 4822 219 10623 4822 219 10624 4822 219 10625 4822 219 10626 4822 219 10627 4822 219 10628 4822 219 10686 4822 600 10866 4822 736 17009 4822 736 17011 4822 736 17012 4822 736 17009 4822 736 17011 4822 736 17012 A d o t t DISASSEMBLY ADVICE + POSSIBLE COMPLAINTS DISASSEMBLY ADVICE N.B. To open the product N.B. CAP 103 will be damaged, when it is removed. For this reason, 2 spare caps are supplied free when you order items 1 and 4 - 9. – To avoid dust from getting into the pump, the suction opening has been closed with a rubber cap. Remove the rubber cap before assembling. – After the product has been repaired, it should function properly and has to meet the safety requirements as laid down and officially established at this moment. Remove CAP 103 ( see picture ) Remove DECORATIVE RING 10 Remove SCREW 2 3x Test Criteria and Controls Total product Adapter: primary voltage secondary voltage N.B. In the underpart the screws are guided by rubber bearings H. ( see cross section ) After ± 10 turns with the screw driver, the screws must be pushed out with the help of a hex key, due to friction between the screws and the rubber bearings ( see picture ) Voltage Ampere 13.0 V 380 mA ± 10 % 220-240 V 13.0 V 400 mA If < 12.5 V adapter is defective Pump 13.0 V 180 mA ± 10 % Motor rollers 13.0 V 180 mA ± 10 % N.B. The opening between Roller 1 and the suction area must be smaller than 0.1 mm. In case the opening is larger, power unit 4 must be replaced. ( see picture ) Pull open the product ( see picture ) Possible complaints. Status Failure Possible Complaint 1. Switch in ' OFF" position Pump functions ON/OFF switch defective 2. Switch set to Level 1 Pump doesn't function Adapter defective ON/OFF switch defective Internal wiring broken defective P.C.B. Motor Pump defective 3. Switch set to level 1 - 5 and product not placed on the skin Product functions Filter is clogged Electronic switch C defective defective P.C.B. 4. Switch set to Level 1- 5 and product properly placed Product doesn't function Electronic switch C defective Defective P.C.B. Sleeves got loose Defective vacuum stop buttons Gearing motor defective Pump clogged - filter missing Internal wiring broken To check if the product functions properly , set the switch to level 1 and cover the suction opening with your thumb. see fig 2 cleaning rollers. PCS 101 216