Download Cellesse HP 5230 Beige / Brown HP 5230 Beige / Green

Transcript
Cellesse
HP 5230 Beige / Brown
HP 5230 Beige / Green
Philips Domestic Appliances and Personal Care
Service manual 4822 729 21748 is herewith cancelled
PRODUCT INFORMATION
Introduction
Type appliance
: 12 V adapter from mains (AC/DC)
Voltage (mains)
: 220-240 V, 50/60 Hz
110-127 V, 50/60 Hz
Motor
: DC type
Max. powerconsumption : 8 watts
Under pressure
: 5 steps from 80 mbar to 250 mbar
Length cord
: 2.5 m
The Cellesse is a special massage system, designed to help reduce
or prevent the unsightly appearance of cellulite.
Cellulite is the increased visibility of lumpy fat deposits through
the surface of the skin. A common used description is ‘orange
peel skin’ because of its unique pitted, lumpy appearance.
Cellulite should not be confused with “cellulitis”, which is a
medical term linked to bacterial infection of the skin.
Cellulite can be reduced with the help of this product.
It can never be completely eliminated and will return when
neglected.
A maximum reduction of the Cellulite layer by 55 % can be
reached after 3 months, if the appliance is used 3 times a week
for 15 mins. on each leg.
The Cellesse does not reduce the fat in the fat layer.
Note: Product meets the requirements regarding
interference suppression on radio and TV.
Published by Philips Domestic Appliances and Personal Care
4822 729 22124
99/02
PCS 101 214
Printed in the Netherlands
© Copyright reserved
Subject to modification
FUNCTIONAL DESCRIPTION OF THE HP5230 CELLESSE
Cleaning the rollers
Function of the Cellesse
The product is connected to the mains and the ON/OFF switch
( A ) is set to level 1 - 5.
The pump ( B ) starts to function.
The pump ( B ) only starts to function if the appliance is in a
proper contact with the skin so a vacuum of at least 80 mbar can
be reached.
Once a vacuum of 80 mbar is reached, the electronic
suppression switch ( C ) switches on the motor ( D ) of the
massage rolls ( E ).
To avoid a painful sucking in of the skin, the vacuum stop
buttons ( F ) can be operated so that the vacuum is eliminated.
The Cellesse only functions properly if the product is put
properly on the skin so that the pump can build up a vacuum in
the sucking area.( G )
To clean the rollers select
Level 1
Fig. 1
Cover the suction opening
with your thumb so the
rollers start to rotate.
Cleaning and Maintenance
Never immerse the appliance in water nor rinse it.
For the best results, keep the Cellesse clean at all times, using a
damp cloth and a spot of detergent, if necessary.
Do not use alcohol, acetone, gasoline, abrasives, scourers and so
on for cleaning the appliance.
When cleaning, special attention should be paid to the rollers on
the underside.
Fig. 2
Wipe the rollers clean with
a damp cloth.
Fig. 3
OLD
VACU-stop Button
W3
red
F
On/off Switch +
Suppression Switch
Level 1-5
C1
A
R6
Q1
not on
PCB
D1
R2
R31
A2
R3
P
W6
red
W4
red
C2
R1
R5
R25
M
M1
W5
blue
A3
R24
W7
blue
Q3
R4 Q21
M1 = Motor rolls
R22
M2 = Pump
R30
Sleeve 105
R27
A1
P-JACK
Q20a
C
R26
8
R29
3
1
W1
blue
7
2
R32
R28
Q20b
C23
C24
C20
R21
C21
D20
R20
6
5
4
DAP0306
Sleeves
Switches on the motor D
automatically at 80 mBar
underpressure
M2
Q2
W2
red
Pump
B
M
Q22
Sleeve 104
El. Suppression Switch
D3
NEW
+13V
TP6
not on
W4
PCB
red
Sucking
Area
G
not on
W1_1
PCB
C3
R1
TP11
not on
W5
PCB
red
Q1
A3
R2
red
W3
Rolls
E
R3
M
W1_2
TP5
SOCKET-PCB
A4
TP7
LEDPCB
W1_2
W9_1
P
A3
D3
M2
blue
blue
W6
W8
A5
TP12
TP14
TP9
TP2
W1_1
M
TP8
TP3
TP1
M1
not on
W3_1
PCB
TP4
A1
P-JACK
TP13
not on
W7
PCB
red
R4
W3_2
TP15
Q2
TP10
W9_2
C4
R5
DAP0777
PCS 101 215
EXPLODED VIEW + PARTS LIST
T
101
7
103
13
A
1
1
2
6
g
D
10
A
102
104
5
8
B
D
B
C
C
9
12
105
4
11
PARTS LIST
Pos Descprition
1
2
4
5
6
7
8
9
10
11
12
set housing parts, consisting of
items 101, 102 and 2 (3x)
screw
power unit
pump
vacuum control unit - on/off
switch
vacuum stop
p.c.b.
set tubes ( item 104 + 105 )
decorative ring
filter
adapter EURO
220-240 V
adapter UK
220-240 V
Service code
Beige/Brown
Beige/Green
Pos Descprition
4822 310 10948
4822 310 11359
12
4822 502 14427
4822 310 10949
4822 310 10951
4822 310 10952
4822 502 14427
4822 310 11361
4822 310 11362
4822 310 11363
4822 310 10953
4822 310 10954
4822 310 10955
4822 466 11484
4822 480 10164
4822 219 10047
4822 219 10202
4822 310 11364
4822 310 11365
4822 310 11366
4822 310 12242
4822 480 10272
4822 219 10618
4822 219 10619
13
adapter
adapter
adapter
adapter
adapter
adapter
adapter
adapter
adapter
pouch
USA
JPN
Korea
Australia
Brazil
PRC
CND
Mexico
Argentina
Service code
Beige/Brown
Beige/Green
110-127 V
100 V
220 V
240 V
115 - 220 V
220 V
110-127 V
110-127 V
240 V
Directions for use F, D, UK, NL, I
Directions for use E, P, TR, Gr
Directions for use DK, S, N, SF
Parts with numbers from 100 and higher cannot be ordered separately
4822 219 10058
4822 219 10059
4822 219 10167
4822 219 10174
4822 219 10277
4822 219 10338
4822 219 10069
4822 219 10455
4822 600 10663
4822 219 10621
4822 219 10622
4822 219 10623
4822 219 10624
4822 219 10625
4822 219 10626
4822 219 10627
4822 219 10628
4822 219 10686
4822 600 10866
4822 736 17009
4822 736 17011
4822 736 17012
4822 736 17009
4822 736 17011
4822 736 17012
A
d
o
t
t
DISASSEMBLY ADVICE + POSSIBLE COMPLAINTS
DISASSEMBLY ADVICE
N.B.
To open the product
N.B. CAP 103 will be damaged, when it is removed.
For this reason, 2 spare caps are supplied free when you
order items 1 and 4 - 9.
– To avoid dust from getting into the pump, the
suction opening has been closed with a rubber cap.
Remove the rubber cap before assembling.
– After the product has been repaired, it should
function properly and has to meet the safety
requirements as laid down and officially established
at this moment.
Remove CAP 103
( see picture )
Remove DECORATIVE
RING 10
Remove SCREW 2 3x
Test Criteria and Controls
Total product
Adapter:
primary voltage
secondary voltage
N.B.
In the underpart the screws are
guided by rubber bearings H.
( see cross section )
After ± 10 turns with the screw
driver, the screws must be pushed
out with the help of a hex key, due
to friction between the screws and
the rubber bearings ( see picture )
Voltage
Ampere
13.0 V
380 mA ± 10 %
220-240 V
13.0 V
400 mA
If < 12.5 V adapter is defective
Pump
13.0 V
180 mA ± 10 %
Motor rollers
13.0 V
180 mA ± 10 %
N.B.
The opening between Roller 1
and the suction area must be
smaller than 0.1 mm.
In case the opening is larger,
power unit 4 must be
replaced.
( see picture )
Pull open the product
( see picture )
Possible complaints.
Status
Failure
Possible Complaint
1. Switch in ' OFF" position
Pump functions
ON/OFF switch defective
2. Switch set to Level 1
Pump doesn't function
Adapter defective
ON/OFF switch defective
Internal wiring broken
defective P.C.B.
Motor Pump defective
3. Switch set to level 1 - 5 and
product not placed on the skin
Product functions
Filter is clogged
Electronic switch C defective
defective P.C.B.
4. Switch set to Level 1- 5 and
product properly placed
Product doesn't function
Electronic switch C defective
Defective P.C.B.
Sleeves got loose
Defective vacuum stop buttons
Gearing motor defective
Pump clogged - filter missing
Internal wiring broken
To check if the product functions properly , set the switch to level 1 and cover the suction
opening with your thumb. see fig 2 cleaning rollers.
PCS 101 216