Download continued - Lochinvar
Transcript
Installation & Operation Manual 12 Diagrams (continued) Figure 12-5 Ladder Diagram_5.0 Model NEUTRAL JUNCTION BOX L1 L2 L3 TERMINAL STRIP 208V 3 BOX DEPICTS OPTIONAL ITEMS TERMINAL STRIP 208V SUPPLY "N" SUPPLY BOX DEPICTS DUAL SENSOR SINGLE HOUSING INTEGRATED CONTROL X1-3 MODBUS BOARD 1.5A EACH MAX ON/OFF SWITCH X1-12 3.15 A 5.0 A SYSTEM PUMP RELAY BOILER PUMP RELAY SYSTEM PUMP CONTACTOR X1-2 INTEGRATED CONTROL BOLIER PUMP CONTACTOR X1-4 DHW PUMP RELAY X8-20 DHW PUMP CONTACTOR X1-8 X2-4 SMALL GAS VALVE RELAY X10-1 LOW VOLTAGE 120 VAC HIGH VOLTAGE X1-1 X10-2 LARGE GAS VALVE RELAY SMALL BLOWER CONTACTOR LARGE BLOWER CONTACTOR X10-3 LARGE GAS VALVE RELAY X10-6 SMALL GAS VALVE RELAY X10-5 GAS VALVE (LARGE) X6-1 F4 X6-3 F2 GROUND X4-1 X4-2 X4-3 X6-2 X1-6 TERMINAL STRIP GAS VALVE (SMALL) LARGE CONNECTION BOARD CN6-3 X8-10 CN6-2 X8-1 CN6-1 X7-8 CN3-6 X7-7 CN3-7 X8-13 CN3-14 X8-14 CN3-13 X8-12 CN3-12 X8-11 CN3-11 X8-5 CN3-10 X8-15 CN3-4 CN3-9 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 X10-4 FLAME SENSE 2 X1-3 X8-6 X1-7 X1-10 SPARK GENERATOR SPARK ROD FLAME SENSE 1 X2-5 CN3-8 X8-16 CN3-1 X8-7 CN3-2 X8-17 CN3-3 SHIELD A B MODBUS OPTION SHIELD 0-10V 0-10V + + - RATE OUT BOILER PUMP OUT SYSTEM RETURN SENSOR SYSTEM SUPPLY SENSOR TANK SENSOR OUTDOOR SENSOR 0-10V + - BMS IN 0-10V + - SYSTEM PUMP IN SHIELD A B CASCADE SHIELD X6-3 X8-18 X6-1 CN3-4 X6-10 X11 X2-5 X8-3 USB INTERFACE SMALL BLOWER CONTACTOR -T X13-4 INLET SENSOR X8-8 -T OUTLET SENSOR (S9) SMALL BLOWER X8-2 1 2 3 -T OUTLET SENSOR (S1) X8-4 LARGE BLOWER CONTACTOR 4 -T FLUE SENSOR LARGE BLOWER X8-9 1 2 3 -T FLUE SENSOR (S10) X7-1 4 -T PRE-MIX SENSOR 1 (S11) X7-5 MODBUS X1-1 -T X1-2 PRE-MIX SENSOR 1 (S13) X1-3 X7-2 FLUE DAMPER TRANSFORMER -T PRE-MIX SENSOR 2 (S12) X7-6 -T PRE-MIX SENSOR 2 (S14) FLUE DAMPER 1 M X6-18 1 X6-9 2 X6-17 4 X6-8 5 2 SMALL BLOWER 3 24V TRANSFORMER 1 LWCO PROBE LARGE BLOWER J3-6 J3-5 X13-2 2 TEST SWITCH J3-3 J3-2 X13-3 4 LWCO RESET J2-1 LWCO BOARD J3-4 5 X4 J2-2 RIBBON CABLE INTEGRATED CONTROL CN1 CN3 LCD DISPLAY X6-5 GPS1 GPS2 X6-15 X6-12 BLOWER PROVING SWITCH (SMALL) X13-1 BLOCKED FLUE SWITCH X6-6 BLOCKED DRAIN SWITCH X3-3 CN1-4 X3-4 CN1-5 X3-1 CN1-6 X3-2 CN1-12 CN1-10 X5-1 X5-7 X6-11 CN1-11 X5-2 X6-2 CN1-9 X5-8 X6-14 CN1-8 CN1-7 X5-3 "X5" BLOCK WIRING IS MODEL DEPENDANT X5-9 X6-13 X5-4 X6-4 X5-10 DU941 SMALL CONNECTION BOARD GPS3 BLOWER PROVING SWITCH (LARGE) CN1-1 HIGH LIMIT SWITCH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ALARM CONTACTS RUN-TIME CONTACTS TANK THERMOSTAT R W ENABLE LOUVER PROVING 24 VAC LOUVER RELAY COIL AUX SWITCH 1 AUX SWITCH 2 CN1-2 CN1-3 X5-5 X5-41 X5-6 X5-12 Notes: 1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada. 2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a minimum of 105°C. Exceptions: Replacement high voltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components. 3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using diagrams to troubleshoot unit. LADDER DIAGRAM LBL20272 REV A 62