Download MAINTENANCE INTERVALS - Safety
Transcript
124 Maintenance Section Boom, Stick, and Frame - Inspect Illustration 167 SEBU7452-07 g00844856 6. Apply lubricant through the fitting at the joint that is between the boom and the stick. Illustration 170 g00844880 9. Apply lubricant through the fitting at the swing cylinder head end. The fitting is accessed through the filter element access cover on the right side of the machine. i02860835 Boom, Stick, and Frame Inspect SMCS Code: 6501; 6502; 6506 All earthmoving equipment is prone to a high degree of wear. Regular inspections for structural damage are necessary. Illustration 168 g00844861 7. Apply lubricant through the following fittings: • (1) The fitting at the stick cylinder rod end. • (2) The fitting at bucket cylinder head end. The interval between these inspections depends on the factors that follow. • The age of the machine • The severity of the application • The loads that have been carried on the machine • The amount of routine servicing that has been carried out If the machine has been involved in any kind of accident, the machine must be inspected thoroughly. Inspect the machine regardless of the date of the last inspection. The machine must be clean before the machine is inspected. Illustration 169 g00844876 8. Apply lubricant through the fitting that is located at the swing cylinder rod end. Proper repair of frames and structures requires specific knowledge of the following subjects. • Materials that have been used to manufacture the frame members • Frame member construction