7.7 CO2 sensor (Xcell 300 QVI model only) German translations from the PCB: - Rauchmelder – Smoke Detector - Feuchtesensor – Humidity Sensor - CO2 Sensor – CO2 Sensor - Eing‡nge 24V – 24V DC Inputs - EIN – Input - Ausg‡nge 24V – 24V DC Outputs - AUS – Output The Connection PCB is situated under a metal Cover Plate on top of the MVHR. Remove the four fixing screws to remove the Cover Plate. Ensure all cables are fitted to the PCB via the rubber grommets also located on top of the MVHR. When all connections have been made, replace the Cover Plate and secure with the four fixing screws provided. Note: 1. When a CO2 Sensor is connected to the PCB, the link wire between RM and RM must not be removed. 2. When a CO2 Sensor is connected to the PCB, the link wire between EIN_0 and EIN_1 must be removed. 3. After the initial installation or once the power is restored following a power loss, the MVHR will only become operational by pressing the manual re-set switch, if fitted, see note below. a. A manual re-set switch is only required if no other switch is fitted together with the CO2 Sensor shown above. See section 6.6 for the range of automatic switch accessories available for the Xcell 300 QVI MVHR. 21