Download general information
Transcript
9-12 DR-Z400EY (E-24 MODEL) SIDE-STAND/IGNITION INTERLOCK SYSTEM This side-stand/ignition interlock system is to prevent starting the motorcycle with the side-stand left down. SIDE-STAND RELAY INSPECTION First check the insulation between D and E terminals with the tester. Then apply 12 V to terminals D and C (+ to D and - to C) and check the continuity between D and E. If there is no continuity, replace the turn signal/side-stand relay with a new one. [ 09900-25008: Multi circuit tester set Side-stand relay Diode < Tester knob indication: Continuity test (>) Turn signal relay DIODE INSPECTION Measure the voltage between the terminals using the multi circuit tester. Refer to the following table. - Probe of tester to: Unit: V + Probe of tester to: C, B C, B A A 1.4 – 1.5 0.4 – 0.6 [ 09900-25008: Multi circuit tester set Tester knob indication: Diode test (= =) NOTE: If the multi circuit tester reads under 1.4 V, replace its battery when the tester probes are not connected. NEUTRAL SWITCH (9-13) SIDE-STAND SWITCH INSPECTION Disconnect the side-stand switch lead wire coupler and measure the voltage between Green and Black/White lead wires. [ 09900-25008: Multi circuit tester set Tester knob indication: Diode test (=) NOTE: If the multi circuit tester reads under 1.4 V, replace its battery when the tester probes are not connected. Green Black/White (+ Probe) (- Probe) ON (Up-right position) 0.4 – 0.6 V OFF (Down position) 1.4 – 1.5 V