Download Instructions For Servicing The Necchi Supernova Sewing Machine
Transcript
Remove top cover. Disconnect pull-rod " A " from pin " B " (Fig. 37) by pushing it to the left with a screw-driver or, still better, with a finger. To facilitate this operation, remove first the cams from the machine, then swing the cam disengaging lever entirely backward toward the machine arm. Fig. 37 Loosen the four screws " C " completely. Raise the mounting plate " D " for the Automatic Device inward. 41 Copyright -2004