Download AIR-CONDITIONER

Transcript
FILE NO. SVM-05015
1. SPECIFICATIONS
1-1
MODEL
ITEM
Cooling
Capacity
kW
RAS-18UFP-E4/18UA-E4
RAS-18UFHP-E4/18UAH-E4
220V
RAS-18UFPX4/18UAX4
Heating
240V
5.00
Cooling
220V
240V
220V
240V
220V
240V
220V
5.70
5.80
5.20
5.25
5.35
5.35
5.10
Phase
Power source
RAS-18UFP-AR4/18UA-AR4 RAS-18UFPX4-T2/18UAX4-T2
1∅
V
220 – 240
220
Hz
50
Power consumption
W
2000
2130
1830
2000
2000
2120
2020
2140
Power factor
%
95
87
93
84
96
91
95
83
98
Indoor
A
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.40
0.45
Outdoor
A
9.20
9.85
8.50
9.50
9.05
9.30
9.30
10.30
7.00
Running current
Starting current
A
Moisture removal
Noise
Refrigerant
42
2.0
45
lit/h
Indoor (H/M/L)
dB
Outdoor
dB
53
53
54
51
52
1.15
1.17
1.47
Ø 15.88
∅6.35
Liquid side size mm
Connection type
pipe
Maximum length m
15*1
(One way)
Flare connection
20*2
Maximum height m
8
difference
INDOOR UNIT
RAS-18UFP-E4
RAS-18UFHP-E4
RAS-18UFP-AR4
RAS-18UFPX4
Width
mm
Height
mm
633
Depth
mm
208
Net weight
RAS-18UFPX4-T2
1093
kg
23
Evaporator type
Finned tube
Indoor fan type
Multi blade fan
High fan
m3/h
800
830
800
Medium fan
m3/h
680
700
680
730
Low fan
m3/h
580
650
580
580
Fan motor output
W
900
50
Air filter
Washable -filter
OUTDOOR UNIT
RAS-18UA-E4
RAS-18UAH-E4
RAS-18UA-AR4
RAS-18UAX4
RAS-18UAX4-T2
Width
mm
830
780
880
Height
mm
538
550
690
Depth
mm
300
270
kg
54
Net weight
310
41
Condenser type
44
51
Finned tube
Outdoor fan type
Propeller fan
m3/h
Airflow volume
Fan motor output
2105
2310
W
Model
Output
2105
2310
W
2200
2120
2200
42
2JS350D5A02
PH340X3C-4KT1
1700
1500
IOL, Td Sensor
3380
65
PH340X3C-4KTS1
1800
PH290X2C-4FT1
1700
IOL
Louver type
Usable outdoor temperature range °C
2120
65
Safety device
Note
46/43/41/38/36
56
Flare connection
Interconnection
Compressor
1.20
∅12.70
mm
Connection type
Dimensions
53
Capillary tube
Gas side size
Air volume
52
R-22
kg
Refrigerant control
Dimensions
42
43/41/39/37/36
52
Name of refrigerant
Rated amount
50
1610
Automatic louver
15 ~ 43
–10 ~ 24
*1 Chargeless pipe
*2 Maximum pipe
–4–
15 ~ 43
21 ~ 52
21 ~ 43