Download INSTALLATION INSTRUCTION
Transcript
Premier Heat Pumps - Air conditioner installation / service manual INSTALLATION - Tools required 2.1 Tools Screw driver Hand drill Ruler, knife Assembly, disassmbly Indoor installation plate fixing Ruler: Length & distance measurement. Knife: Tape cutting Core drill (diameter 70mm) Monkey spanner (300mm): 2EA Torque wrench Wall through Indoor/Outdoor pipe connection Indoor/outdoor pipe connection Clamp meter Gas leak detector & soup water Thermometer Hex. wrench (Large side: 4mm, 5mm) Leak inspection Temperature measurement at Indoor suction inlet/discharge outlet. Service valve operating Insulation Hook meter (for current measurement) resistance meter Current, voltage, resistance measurement Insulation resistance measurement (Electric shock prevention) Flare tool set Pipe cutting, Burr removal Level Thermometer Drive torch Mega tester 2.2 Accessory Connnection cable Winter cover Anti-vibration rubber Indoor-Outdoor Outdoor protection wire connnection in a unusedseason Vibration absorption of outdoor like winter Refrigerant pipe (for high/low pressure) Refrigerant circuit connection to Indoor/Outdoor. Band Adhesive Drain hose Wire & pipe finishing Finishing Drainage Remocon Putty Vinyl tape Remocon fixture Fixture clamping screw Chaging of wallthrough hole Wire & pipe finishing Remocon hanger Remocon fixture fixing Remark: Some of the above parts are provided by the installer and not included in the standard air-conditioner. 3