Download Service Manual 05/2007
Transcript
Electrolux EFS - Dishwashing Systems Platform Electrolux Professional CCu Rin Add tub tty PrE Pty SbI PSS See Par. Indicates the maximum current supplied from the inverter to the gear motor. B2.3 Enter RINSE MODULE and set the following parameters. Time between reaching level “0” (air trap level) in the air gap and stop of rinse pump. 32 Enter tub and set the following parameters. Type of wash module. 2 Enter PrE and set the following parameters. Type of prewash module. 0 Indicates the maximum level in the prewash tank. The filling stops when the 205 170 water level reaches this value. The value for the maximum level is modified from “Standby level” to “Run level” during prewashing phase in order to avoid water loss whan the pumps stop. Switch the machine off and then on again. DOC. N. 5956.573.02 Page 52 / 80