Download Golden Tee GOLF 2013
Transcript
To Purchase This Item, Visit BMI Gaming | www.bmigaming.com | (800) 746-2255 | +1.561.391.7200 Control Problems Symptom Button does not work. Button always indicates closed in the player control test. Pressing it will show it is not depressed. Button always indicates closed in player control test even with the switch disconnected entirely. Trackball is not functioning in any direction. Probable Cause Switches Common post is not connected to digital ground. Signal wire is not connected to the Normally Open post of the switch. Switch is defective. Signal wire is connected to the Normally Closed post of the switch. Defective I/O Board. Test on a known good system. Replace if necessary. Trackball is not connected to the I/O Board properly. Verify the trackball is connected to J208 labeled trackball on the I/O Board. Verify continuity on the trackball Interconnect cable. Replace trackball. Replace I/O Board. Try it on a known good system. Verify continuity on the trackball cable. Repair or replace if needed. Repair or replace the trackball. Try it on a known working system. Repair or replace the I/O Board. Try it on a known working system. Clean the inside of the trackball. Replace the rollers and bearings. Do not over-tighten the trackball. Tighten just enough to flatten the lock washers. Defective trackball Interconnect cable. Trackball is defective. I/O Board is defective Trackball does not work in a certain direction. Trackball cable is defective. Trackball is defective. I/O Board is defective. Trackball works intermittently. Solution Verify continuity to digital/power supply ground. Verify continuity from the I/O Board to the Normally Open post of the switch. Replace defective switch. Connect signal wire to the Normally Open post of the switch. Inside of the trackball is dirty. Rollers are worn. Trackball is over-tightened. HDTV Video Problems Symptom Probable Cause Solution Incorrect video cable configuration. Be sure you are using the proper cable connections. Refer to the HDTV connections configurations. Connected to the wrong output on the system box Refer to the HDTV connections configurations. Connected to the wrong input on the HDTV HDTVs usually have more than 1 input for a certain input type. Examples are Component 1 & 2; HDMI 1 & 2. Incorrect input selected on the HDTV Be sure the correct input is selected from the HDTV input menu. Example: If using HDMI 1 that input must be selected from the HDTV video input menu. DIP switch setting SW 201 on the I/O Board set incorrectly. Sw201 on the I/O Board must be configured to match the method of video you are using. There is no picture during boot up. Golden Tee GOLF™ Version 11/12 Page 48 © Copyright 2012 Incredible Technologies, Inc. All Rights Reserved. Unauthorized duplication is a violation of applicable law. All other marks are the properties of their respective owners. All rights reserved.