Download Golden Tee GOLF 2013

Transcript
To Purchase This Item, Visit BMI Gaming | www.bmigaming.com | (800) 746-2255 | +1.561.391.7200
Control Problems
Symptom
Button does not work.
Button always indicates closed in
the player control test. Pressing it
will show it is not depressed.
Button always indicates closed in
player control test even with the
switch disconnected entirely.
Trackball is not functioning in any
direction.
Probable Cause
Switches Common post is not
connected to digital ground.
Signal wire is not connected to the
Normally Open post of the switch.
Switch is defective.
Signal wire is connected to the
Normally Closed post of the switch.
Defective I/O Board.
Test on a known good system.
Replace if necessary.
Trackball is not connected to the
I/O Board properly.
Verify the trackball is connected to
J208 labeled trackball on the I/O
Board.
Verify continuity on the trackball
Interconnect cable.
Replace trackball.
Replace I/O Board. Try it on a
known good system.
Verify continuity on the trackball
cable. Repair or replace if needed.
Repair or replace the trackball. Try it
on a known working system.
Repair or replace the I/O Board. Try
it on a known working system.
Clean the inside of the trackball.
Replace the rollers and bearings.
Do not over-tighten the trackball.
Tighten just enough to flatten the
lock washers.
Defective trackball Interconnect
cable.
Trackball is defective.
I/O Board is defective
Trackball does not work in a
certain direction.
Trackball cable is defective.
Trackball is defective.
I/O Board is defective.
Trackball works intermittently.
Solution
Verify continuity to digital/power
supply ground.
Verify continuity from the I/O Board
to the Normally Open post of the
switch.
Replace defective switch.
Connect signal wire to the Normally
Open post of the switch.
Inside of the trackball is dirty.
Rollers are worn.
Trackball is over-tightened.
HDTV Video Problems
Symptom
Probable Cause
Solution
Incorrect video cable configuration.
Be sure you are using the proper
cable connections. Refer to the
HDTV connections configurations.
Connected to the wrong output on
the system box
Refer to the HDTV connections
configurations.
Connected to the wrong input on
the HDTV
HDTVs usually have more than 1
input for a certain input type.
Examples are Component 1 & 2;
HDMI 1 & 2.
Incorrect input selected on the
HDTV
Be sure the correct input is selected
from the HDTV input menu.
Example: If using HDMI 1 that input
must be selected from the HDTV
video input menu.
DIP switch setting SW 201 on the
I/O Board set incorrectly.
Sw201 on the I/O Board must be
configured to match the method of
video you are using.
There is no picture during boot up.
Golden Tee GOLF™
Version 11/12
Page 48
© Copyright 2012 Incredible Technologies, Inc. All Rights Reserved. Unauthorized duplication is a violation of applicable law.