32. (00100000) Phase 1 - Pump Circuit Error The Display Module has detected that the pump is on when it is off. Primary Source - Display Module Action 1. Check for moisture in the console area. 2. Replace the Display Module. 33. (00100001) Phase 1 - Water Valve Fault The Module has detected a water valve fault. Primary Source - Water Valve connection Action - Check that both valves are connected up properly. Secondary Source - Water Valve coil faulty Action 1. Check the valve coils are not open circuit. 2. Replace Display Module if valve coils are not faulty. 34. (00100010) Phase 1 - Brake Resistor Fault The circuit that controls the braking of the motor is faulty. Primary Source - Motor Controller Action - Replace the Motor Controller Secondary Source - Display Module Action - Replace the Display Module. If the Display Module corrects the fault, then re-fit the original Motor Controller. 35. (00100011) Phase 1 - MC Reset Error The Display Module has sent a false signal to the Motor Controller. Primary Source - 12 way Harness Connection. Action - Check the 12 way harness connection between the Display Module and the Motor Controller. Secondary Source - Display Module Action - Replace the Display Module. - 46 -