Q200 Series - Self-Contained Water-Cooled Characteristics may vary depending on operating conditions. CYCLE TIMES Freeze Time + Harvest Time = Total Cycle Time Air Temp. Around Ice Machine °F/°C Freeze Time Water Temperature °F/°C 50/10.0 70/21.1 90/32.2 70/21.1 11.5-13.5 12.8-15.0 14.5-16.9 80/26.7 12.0-14.1 13.5-15.7 15.2-17.8 90/32.2 12.6-14.7 14.1-16.5 16.1-18.7 100/37.8 13.1-15.4 14.8-17.3 17.0-19.8 Harvest Time 1-2.5 Times in minutes 24 HOUR ICE PRODUCTION Water Temperature °F/°C Air Temp. Around Ice Machine °F/°C 50/10.0 70/21.1 90/32.2 70/21.1 270 245 220 80/26.7 260 235 210 90/32.2 250 225 200 100/37.8 240 215 190 Based on average ice slab weight of 2.44 - 2.81 lb. Regular cube derate is 7% CONDENSER WATER CONSUMPTION Air Temp. Around Ice Machine 90°F/32.2°C Gal/24 hours Water Temperature °F/°C 50/10.0 70/21.1 90/32.2 240 480 2100 Water regulating valve set to maintain 230 PSIG discharge pressure OPERATING PRESSURES Freeze Cycle Harvest Cycle Air Temp. Around Ice Machine °F/°C Discharge Pressure PSIG Suction Pressure PSIG Discharge Pressure PSIG Suction Pressure PSIG 50/10.0 225-235 60-28 170-200 90-110 70/21.1 225-235 60-28 170-200 90-110 80/26.7 225-240 60-28 175-205 90-110 90/32.2 225-245 65-30 175-205 90-115 100/37.8 225-250 70-32 180-210 90-115 110/43.3 225-260 75-34 185-215 90-120 Suction pressure drops gradually throughout the freeze cycle –121–