VENT MOTOR CAPACITOR
The Vent motor capacitor is located directly behind the control panel.
It is in use any time the Vent motor is on. The capacitor helps to maintain a constant voltage to the Vent motor so that it
runs more efficiently.
TEST CHARTS
COMPONET
High Voltage Transformer(With wire leads unplugged)
TEST PROCEDURE
1. Set the ohmmeter to the Rx1
scale, and measure the:
a) Primary winding
b) Secondary winding
c) Filament winding
2. Set the ohmmeter to its Rx1000
scale, and measure the:
a) Primary to ground
b) Filament to ground
Magnetron(with wire leads unplugged)
NOTE
A microwave energy leakage test must always
be performed when the oven is serviced for
any reason.
1. Set the ohmmeter to its Rx1000
scale, and measure the:
a) Filament terminal
2. Set the ohmmeter to its Rx1000
scale, and measure the:
a) Filament winding to chassis
NOTE
Replace the magnetron if the checks and all of
the high voltage component tests are good,
but the unit still does not heat a load
38
RESULT
a) 0.4 to 0.6 ohms
b) 70 to 130 ohms
c) 0 ohms
a) Normal = infinity
b) Normal = infinity
a) Normal readings
less than 1
a) Normal = infinity