Download technical data & service manual split system air conditioner
Transcript
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER Model No. KPAFP125R5I KPAFP165R5I KPAFP185R5I Product Code No. 38.7105.956 38.7105.958 38.7105.957 0.8180.451.1 09/2006 IMPORTANT! Please read before installation This air conditioning system meets strict safety and operating standards. For the installer or service person, it is important to install or service the system so that it operates safely and efficiently. For safe installation and trouble-free operation, you must: • Carefully read this instruction booklet before beginning. • Follow each installation or repair step exactly as shown. • Observe all local, state and national electrical codes. • Pay close attention to all warning and caution notices given in this manual. •The unit must be supplied with a dedicated electrical line. • Ground the unit following local electrical codes. • The Yellow/Green wire cannot be used for any connection different from the ground connection. • Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard. • Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan. • Do not use multi-core cable when wiring the power supply and control lines. Use separate cables for each type of line. When transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminium fins on the air conditioner can cut your fingers. WARNING This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. When installing... … In a ceiling Make sure the ceiling is strong enough to hold the unit-weight. It may be necessary to build a strong wooden or metal frame to provide added support. … In a room CAUTION This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. Properly insulate any tubing run inside a room to prevent "sweating", which can cause dripping and water damage to walls and floors. ... In moist or uneven locations If necessary, get help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sale/service outlet or your certified dealer for additional instructions. Use a raised concrete base to provide a solid level foundation for the outdoor unit. This prevents damage and abnormal vibrations. ... In area with strong winds Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle. In case of improper installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document. ... In a snowy area (for heat pump-type systems) SPECIAL PRECAUTIONS When connecting refrigerant tubing • During installation, connect before the refrigerant system and then the wiring one; proceed in the reverse orden when removing the units. • Keep all tubing runs as short as possible. • Use the flare method for connecting tubing. • Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them; screw by hand and then tighten the nut with a torque wrench for a leak-free connection. • Check carefully for leaks before starting the test run. WARNING When wiring ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY QUALIFIED, EXPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM. • Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked, to ensure the grounding. • Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury and death. 2 Install the outdoor unit on a raised platform that is higher then drifting snow. Provide snow vents. NOTE: Depending on the system type, liquid and gas lines may be either narrow or wide. Therefore, to avoid confusion, the refrigerant tubing for your particular model is specified as narrow tube for liquid, wide tube for gas. When servicing • Turn the power OFF at the main power board before opening the unit to check or repair electrical parts and wiring. • Keep your fingers and clothing away from any moving parts. • Clean up the site after the work, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced. • Ventilate the room during the installation or testing the refrigeration system; make sure that, after the installation, no gas leaks are present, because this could produce toxic gas and dangerous if in contact with flames or heat-sources. Table of Contents Page 4 4 6 8 1. SPECIFICATIONS 1-1 Unit specifications 1-2 Major Component specifications 1-3 Other Component specifications 9 2. DIMENSIONAL DATA 10 10 11 3. ELECTRICAL DATA 3-1 Electric Wiring Diagram 3-2 Control PCB switches and functions 12 12 4. PROCESS AND FUNCTIONS 4-1 Control function 5. REPLACING PCB 5-1 Replacing PCB 5-2 How to replace PCB 5-3 How to replace EEPROM with EEPROM included in PCB service pack 5-4 Table of setting 6. SERVICE PROCEDURE 6-1 Meaning of alarm message 6-2 Led indicator messages on outdoor control PCB 6-3 Symptoms and parts to inspect 6-4 Details of alarm messages 6-5 Table of thermistor characteristics 7. OUTDOOR UNIT MAINTENANCE REMOTE CONTROL 7-1 Overwiew 7-2 Functions 7-3 Normal display operations and functions 7-4 Monitoring operations: Display of indoor unit and outdoor unit sensor temperatures 7-5 Monitoring the outdoor unit alarm history: Display of outdoor unit alarm history 7-6 Setting modes: setting of outdoor unit EEPROM 3 15 15 16 17 19 20 20 21 22 23 26 27 27 27 28 31 32 32 1. SPECIFICATIONS 1-1 Unit Specifications KPAFP125R5I Power source 220 - 240V ~ 50Hz Voltage rating 230V Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) Fan speed Airflow direction Air Filter Sound pressure level Refrigerant tubing connections Refrigerant tube diameter Refrigerant Refrigerant control Dimensions & Weight Dimensions Package dimensions Weight Unit Unit wired wireless high/med/low dB(A) Narrow tube Wide tube mm(in.) mm(in.) Height Width Depth Height Width Depth Volume Net Shipping mm mm mm mm mm mm m3 kg kg 4 Cooling Heating See catalogue with the requested matching 700/590/500 Microprocessor/ I.C. thermostat K70D036Z / K70D042Z K70D038Z / K70D040Z 3 and Auto Auto (Remote control) Washable 55/51/46 Flare type 6,35 (1/4) 12,7 (1/2) R410A Electronic expansion valve 680 900 190 813 296 1011 0,24 23,5 31,5 DATA SUBJECT TO CHANGE WITHOUT NOTICE KPAFP165/185R5I Power source 220 - 240V ~ 50Hz Voltage rating 230V Performance Capacity Air circulation (High/Med./Low) m³/h Features Controls/Temperature controls Remote Controller (Option) Fan speed Airflow direction Air Filter Sound pressure level Refrigerant tubing connections Refrigerant tube diameter Refrigerant Refrigerant control Dimensions & Weight Dimensions Package dimensions Weight Unit Unit wired wireless high/med/low dB(A) Narrow tube Wide tube mm(in.) mm(in.) Height Width Depth Height Width Depth Volume Net Shipping mm mm mm mm mm mm m3 kg kg 5 Cooling Heating See catalogue with the requested matching 830/760/665 Microprocessor/ I.C. thermostat K70D036Z / K70D042Z K70D038Z / K70D040Z 3 and Auto Auto (Remote control) Washable 60/57/54 Flare type 6,35 (1/4) 12,7 (1/2) R410A Electronic expansion valve 680 900 190 813 296 1011 0,24 23,5 31,5 DATA SUBJECT TO CHANGE WITHOUT NOTICE 1-2 Major Component Specifications KPAFP125R5I Controller PCB Part No. Controls CR-CRP50A-B Microprocessor Fan & Fan Motor Type Q'ty ……. Dia. and lenght Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps Power input Coil resistance (Ambient temp. 25 °C ) Safety devices Type Operating temp. Open Close Run capacitor Flap motor Model Rating Rpm Nominal output Coil resistance Heat Exch. Coil Coil Rows Fin pitch face area mm A W Ω °C °C µF VAC W kΩ (25°C) Centrifugal fan 2…. Ø 130 L 180 K48407-MO1596 …1 4… 1160 0,29 65 GRY-WHT: 194 ÷ 223 WHT-PNK: 238 ÷ 274 WHT-VLT: 80,1 ÷ 92,2 VLT-ORG: 80,1 ÷ 92,2 ORG-YEL: 200 ÷ 230 Internal thermal protector 145 ± 5K Automatic reclosing 1,5 450 M2LB24ZA12 240 VAC 2,5 3 15,62 ± 15% Aluminium plate fin / Copper tube 2 1,8 mm 0,167 m2 DATA SUBJECT TO CHANGE WITHOUT NOTICE 6 KPAFP165/185R5I Controller PCB Part No. Controls CR-CRP50A-B Microprocessor Fan & Fan Motor Type Q'ty ……. Dia. and lenght Fan motor model…Q'ty No. Of poles…rpm (230 V, High) Running Amps Power input Coil resistance (Ambient temp. 25 °C ) Safety devices Type Operating temp. Open Close Run capacitor Flap motor Model Rating Rpm Nominal output Coil resistance Heat Exch. Coil Coil Rows Fin pitch face area mm A W Ω °C °C µF VAC W kΩ (25°C) Centrifugal fan 2…. Ø 130 L 180 K48410-MO1598 …1 4… 1160 0,41 88 GRY-WHT: 124 ÷ 144 WHT-PNK: 255 ÷ 294 WHT-VLT: 69,3 ÷ 79,8 VLT-ORG: 69,3 ÷ 79,8 ORG-YEL: 200 ÷ 233 Internal thermal protector 145 ± 5K Automatic reclosing 2 440 M2LB24ZA12 240 VAC 2,5 3 15,62 ± 15% Aluminium plate fin / Copper tube 3 1,6 mm 0,167 m2 DATA SUBJECT TO CHANGE WITHOUT NOTICE 7 1-3 Other Component Specifications Trasformer Rating ATR-IIJ225A VAC 230V, 50Hz AC 20V - 0.2A AC 14V - 0.3A AC 10,2V - 1.4A Primary Secondary 1 Secondary 2 Secondary 3 136°C Thermal cut-off temp. Thermistor ( Coil sensor E1, E2) Resistance kΩ PBC-41E-S26 0 °C 15,0 ± 5% Thermistor ( Room sensor TA) Resistance kΩ DHKTEC-35-S85N 25 °C 5,0 ± 4% 8 2. DIMENSIONAL DATA Units: mm 9 3. ELECTRICAL DATA 3-1 Electric Wiring Diagram 7P terminal board 1(L) 2(N) power supply U1 U2 inter-unit control wiring R1 R2 remote controller 10 3-2 Control PCB switches and functions CR-TRP50A-B OC (CN040) EMG (CN044) VARISTOR (VA041) EXCT (CN073) JP1 (JP001) FILTER (CN070) DISP (CN072) CHK (CN071) FAN DRIVE (CN032) GRL (CN020) POWER LED (D002) T10 (CN061) EEPROM (IC010) T10: (CN061) 6 plug (yellow): used for remote control. (Refer to the remote control section) 1- start/stop input 2- COM 3- remote control prohibit/release input 4- start signal output 5- COM (+DC12v) 6- alarm signal output T10 EXCT: (CN073) 2P plug (red): Can be used for demand control. When imput is present, forces the unit to operate with the termostat OFF. DISP: (CN072) 2P plug (white): Short-circuiting this plug allows the unit to be operated by the remote controller, even if it is not connected to an outdoor unit. (In this case, alarm "E04", which indicates trouble in the serial communication between the indoor and outdoor unit, does not occur.) CHK: (CN071) 2P plug (white): Test pin. Short-circuiting this pin allows the indoor FM (H fan speed), drain pump, flap motor (F1 position), and electronic expansion valve full-open position to checked. However this function turns OFF if the indoor unit protection mechanism is activated. The unit can be operated even if the remote controller and outdoor unit are not connected. However even if the remote controller cannot is connected, it cannot be used to operate the unit. This function can be used for short-term tests. JP1: (JP001) Jumper wire: Allows selection of the T10 terminal 11 4. PROCESS AND FUNCTIONS 4-1 control functions 12 13 14 5. REPLACING PCB 5-1 Replacing PCB About EEPROM (Erasable Programmable Read-Only Memory) EEPROM is a component in which the various information necessary for functionning can be electronically written or erased. This component holds informations that is essential for the running of the unit, and must be handled with care. D002 led lamp (red) 15 5-2 How to replace PCB 16 5-3 How to replace EEPROM with EEPROM included in PCB service pack 17 18 5-4 Table of settings 19 6. SERVICE PROCEDURE 6-1 Meaning of alarm message 20 6-2 Led indicator messages on outdoor control PCB 21 6-3 Symtoms and parts to inspect 22 6-4 Details of alarm messages resistance 23 24 25 26 7. OUTDOOR UNIT MAINTENANCE REMOTE CONTROL 27 28 29 30 31 32 33 34 R.D. 28 Reyrieux BP 131 - 01601 Trévoux CEDEX France Tél. 04.74.00.92.92 - Fax 04.74.00.42.00 R.C.S. Bourg-en-Bresse B 759 200 728