Download technical data & service manual split system air conditioner

Transcript
TECHNICAL DATA
& SERVICE MANUAL
SPLIT SYSTEM AIR CONDITIONER
Model No.
KPAFP125R5I
KPAFP165R5I
KPAFP185R5I
Product Code No.
38.7105.956
38.7105.958
38.7105.957
0.8180.451.1
09/2006
IMPORTANT!
Please read before installation
This air conditioning system meets strict safety and operating
standards.
For the installer or service person, it is important to install or
service the system so that it operates safely and efficiently.
For safe installation and trouble-free operation, you must:
• Carefully read this instruction booklet before beginning.
• Follow each installation or repair step exactly as shown.
• Observe all local, state and national electrical codes.
• Pay close attention to all warning and caution notices given in
this manual.
•The unit must be supplied with a dedicated electrical line.
• Ground the unit following local electrical codes.
• The Yellow/Green wire cannot be used for any connection
different from the ground connection.
• Connect all wiring tightly. Loose wiring may cause overheating
at connection points and a possible fire hazard.
• Do not allow wiring to touch the refrigerant tubing, compressor,
or any moving parts of the fan.
• Do not use multi-core cable when wiring the power supply and
control lines. Use separate cables for each type of line.
When transporting
Be careful when picking up and moving the indoor and outdoor
units. Get a partner to help, and bend your knees when lifting to
reduce strain on your back. Sharp edges or thin aluminium fins on
the air conditioner can cut your fingers.
WARNING
This symbol refers to a hazard or unsafe practice which can result
in severe personal injury or death.
When installing...
… In a ceiling
Make sure the ceiling is strong enough to hold the unit-weight.
It may be necessary to build a strong wooden or metal frame to
provide added support.
… In a room
CAUTION
This symbol refers to a hazard or unsafe practice which can result
in personal injury or product or property damage.
Properly insulate any tubing run inside a room to prevent
"sweating", which can cause dripping and water damage to
walls and floors.
... In moist or uneven locations
If necessary, get help
These instructions are all you need for most installation sites and
maintenance conditions.
If you require help for a special problem, contact our sale/service
outlet or your certified dealer for additional instructions.
Use a raised concrete base to provide a solid level foundation
for the outdoor unit. This prevents damage and abnormal
vibrations.
... In area with strong winds
Securely anchor the outdoor unit down with bolts and a metal
frame. Provide a suitable air baffle.
In case of improper installation
The manufacturer shall in no way be responsible for improper
installation or maintenance service, including failure to follow the
instructions in this document.
... In a snowy area (for heat pump-type systems)
SPECIAL PRECAUTIONS
When connecting refrigerant tubing
• During installation, connect before the refrigerant system and
then the wiring one; proceed in the reverse orden when removing
the units.
• Keep all tubing runs as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the flare
and union tubes before connecting them; screw by hand and
then tighten the nut with a torque wrench for a leak-free
connection.
• Check carefully for leaks before starting the test run.
WARNING
When wiring
ELECTRICAL SHOCK CAN CAUSE SEVERE
PERSONAL INJURY OR DEATH. ONLY QUALIFIED,
EXPERIENCED ELECTRICIANS SHOULD ATTEMPT
TO WIRE THIS SYSTEM.
• Do not supply power to the unit until all wiring and tubing are
completed or reconnected and checked, to ensure the grounding.
• Highly dangerous electrical voltages are used in this system.
Carefully refer to the wiring diagram and these instructions when
wiring.
Improper connections and inadequate grounding can cause
accidental injury and death.
2
Install the outdoor unit on a raised platform that is higher then
drifting snow. Provide snow vents.
NOTE:
Depending on the system type, liquid and gas lines may be either
narrow or wide. Therefore, to avoid confusion, the refrigerant
tubing for your particular model is specified as narrow tube for
liquid, wide tube for gas.
When servicing
• Turn the power OFF at the main power board before opening
the unit to check or repair electrical parts and wiring.
• Keep your fingers and clothing away from any moving parts.
• Clean up the site after the work, remembering to check that no
metal scraps or bits of wiring have been left inside the unit being
serviced.
• Ventilate the room during the installation or testing the refrigeration
system; make sure that, after the installation, no gas leaks are
present, because this could produce toxic gas and dangerous
if in contact with flames or heat-sources.
Table of Contents
Page
4
4
6
8
1. SPECIFICATIONS
1-1 Unit specifications
1-2 Major Component specifications
1-3 Other Component specifications
9
2. DIMENSIONAL DATA
10
10
11
3. ELECTRICAL DATA
3-1 Electric Wiring Diagram
3-2 Control PCB switches and functions
12
12
4. PROCESS AND FUNCTIONS
4-1 Control function
5. REPLACING PCB
5-1 Replacing PCB
5-2 How to replace PCB
5-3 How to replace EEPROM with EEPROM included in PCB service pack
5-4 Table of setting
6. SERVICE PROCEDURE
6-1 Meaning of alarm message
6-2 Led indicator messages on outdoor control PCB
6-3 Symptoms and parts to inspect
6-4 Details of alarm messages
6-5 Table of thermistor characteristics
7. OUTDOOR UNIT MAINTENANCE REMOTE CONTROL
7-1 Overwiew
7-2 Functions
7-3 Normal display operations and functions
7-4 Monitoring operations:
Display of indoor unit and outdoor unit sensor temperatures
7-5 Monitoring the outdoor unit alarm history:
Display of outdoor unit alarm history
7-6 Setting modes: setting of outdoor unit EEPROM
3
15
15
16
17
19
20
20
21
22
23
26
27
27
27
28
31
32
32
1. SPECIFICATIONS
1-1 Unit Specifications
KPAFP125R5I
Power source
220 - 240V ~ 50Hz
Voltage rating
230V
Performance
Capacity
Air circulation (High/Med./Low)
m³/h
Features
Controls/Temperature controls
Remote Controller (Option)
Fan speed
Airflow direction
Air Filter
Sound pressure level
Refrigerant tubing connections
Refrigerant
tube diameter
Refrigerant
Refrigerant control
Dimensions & Weight
Dimensions
Package dimensions
Weight
Unit
Unit
wired
wireless
high/med/low
dB(A)
Narrow tube
Wide tube
mm(in.)
mm(in.)
Height
Width
Depth
Height
Width
Depth
Volume
Net
Shipping
mm
mm
mm
mm
mm
mm
m3
kg
kg
4
Cooling
Heating
See catalogue with the requested matching
700/590/500
Microprocessor/ I.C. thermostat
K70D036Z / K70D042Z
K70D038Z / K70D040Z
3 and Auto
Auto (Remote control)
Washable
55/51/46
Flare type
6,35 (1/4)
12,7 (1/2)
R410A
Electronic expansion valve
680
900
190
813
296
1011
0,24
23,5
31,5
DATA SUBJECT TO CHANGE WITHOUT NOTICE
KPAFP165/185R5I
Power source
220 - 240V ~ 50Hz
Voltage rating
230V
Performance
Capacity
Air circulation (High/Med./Low)
m³/h
Features
Controls/Temperature controls
Remote Controller (Option)
Fan speed
Airflow direction
Air Filter
Sound pressure level
Refrigerant tubing connections
Refrigerant
tube diameter
Refrigerant
Refrigerant control
Dimensions & Weight
Dimensions
Package dimensions
Weight
Unit
Unit
wired
wireless
high/med/low
dB(A)
Narrow tube
Wide tube
mm(in.)
mm(in.)
Height
Width
Depth
Height
Width
Depth
Volume
Net
Shipping
mm
mm
mm
mm
mm
mm
m3
kg
kg
5
Cooling
Heating
See catalogue with the requested matching
830/760/665
Microprocessor/ I.C. thermostat
K70D036Z / K70D042Z
K70D038Z / K70D040Z
3 and Auto
Auto (Remote control)
Washable
60/57/54
Flare type
6,35 (1/4)
12,7 (1/2)
R410A
Electronic expansion valve
680
900
190
813
296
1011
0,24
23,5
31,5
DATA SUBJECT TO CHANGE WITHOUT NOTICE
1-2 Major Component Specifications
KPAFP125R5I
Controller PCB
Part No.
Controls
CR-CRP50A-B
Microprocessor
Fan & Fan Motor
Type
Q'ty ……. Dia. and lenght
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Running Amps
Power input
Coil resistance (Ambient temp. 25 °C )
Safety devices
Type
Operating temp. Open
Close
Run capacitor
Flap motor
Model
Rating
Rpm
Nominal output
Coil resistance
Heat Exch. Coil
Coil
Rows
Fin pitch
face area
mm
A
W
Ω
°C
°C
µF
VAC
W
kΩ
(25°C)
Centrifugal fan
2…. Ø 130 L 180
K48407-MO1596 …1
4… 1160
0,29
65
GRY-WHT: 194 ÷ 223
WHT-PNK: 238 ÷ 274
WHT-VLT: 80,1 ÷ 92,2
VLT-ORG: 80,1 ÷ 92,2
ORG-YEL: 200 ÷ 230
Internal thermal protector
145 ± 5K
Automatic reclosing
1,5
450
M2LB24ZA12
240 VAC
2,5
3
15,62 ± 15%
Aluminium plate fin / Copper tube
2
1,8
mm
0,167
m2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
6
KPAFP165/185R5I
Controller PCB
Part No.
Controls
CR-CRP50A-B
Microprocessor
Fan & Fan Motor
Type
Q'ty ……. Dia. and lenght
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Running Amps
Power input
Coil resistance (Ambient temp. 25 °C )
Safety devices
Type
Operating temp. Open
Close
Run capacitor
Flap motor
Model
Rating
Rpm
Nominal output
Coil resistance
Heat Exch. Coil
Coil
Rows
Fin pitch
face area
mm
A
W
Ω
°C
°C
µF
VAC
W
kΩ
(25°C)
Centrifugal fan
2…. Ø 130 L 180
K48410-MO1598 …1
4… 1160
0,41
88
GRY-WHT: 124 ÷ 144
WHT-PNK: 255 ÷ 294
WHT-VLT: 69,3 ÷ 79,8
VLT-ORG: 69,3 ÷ 79,8
ORG-YEL: 200 ÷ 233
Internal thermal protector
145 ± 5K
Automatic reclosing
2
440
M2LB24ZA12
240 VAC
2,5
3
15,62 ± 15%
Aluminium plate fin / Copper tube
3
1,6
mm
0,167
m2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
7
1-3 Other Component Specifications
Trasformer
Rating
ATR-IIJ225A
VAC 230V, 50Hz
AC 20V - 0.2A
AC 14V - 0.3A
AC 10,2V - 1.4A
Primary
Secondary 1
Secondary 2
Secondary 3
136°C
Thermal cut-off temp.
Thermistor ( Coil sensor E1, E2)
Resistance
kΩ
PBC-41E-S26
0 °C 15,0 ± 5%
Thermistor ( Room sensor TA)
Resistance
kΩ
DHKTEC-35-S85N
25 °C 5,0 ± 4%
8
2. DIMENSIONAL DATA
Units: mm
9
3. ELECTRICAL DATA
3-1 Electric Wiring Diagram
7P terminal board
1(L)
2(N)
power
supply
U1
U2
inter-unit
control
wiring
R1
R2
remote
controller
10
3-2 Control PCB switches and functions
CR-TRP50A-B
OC (CN040)
EMG (CN044)
VARISTOR
(VA041)
EXCT (CN073)
JP1
(JP001)
FILTER
(CN070)
DISP (CN072)
CHK (CN071)
FAN DRIVE
(CN032)
GRL
(CN020)
POWER LED
(D002)
T10 (CN061)
EEPROM
(IC010)
T10:
(CN061)
6 plug (yellow): used for remote control. (Refer to the remote control section)
1- start/stop input
2- COM
3- remote control prohibit/release input
4- start signal output
5- COM (+DC12v)
6- alarm signal output T10
EXCT:
(CN073)
2P plug (red): Can be used for demand control. When imput is present, forces the unit to operate
with the termostat OFF.
DISP:
(CN072)
2P plug (white): Short-circuiting this plug allows the unit to be operated by the remote controller, even if it is not
connected to an outdoor unit. (In this case, alarm "E04", which indicates trouble in the serial communication
between the indoor and outdoor unit, does not occur.)
CHK:
(CN071)
2P plug (white): Test pin. Short-circuiting this pin allows the indoor FM (H fan speed), drain pump,
flap motor (F1 position), and electronic expansion valve full-open position to checked. However this function
turns OFF if the indoor unit protection mechanism is activated. The unit can be operated even if the remote
controller and outdoor unit are not connected. However even if the remote controller cannot is connected,
it cannot be used to operate the unit. This function can be used for short-term tests.
JP1:
(JP001)
Jumper wire: Allows selection of the T10 terminal
11
4. PROCESS AND FUNCTIONS
4-1 control functions
12
13
14
5. REPLACING PCB
5-1 Replacing PCB
About EEPROM
(Erasable Programmable Read-Only Memory)
EEPROM is a component in which the various information necessary for functionning
can be electronically written or erased. This component holds informations
that is essential for the running of the unit, and must be handled with care.
D002
led lamp (red)
15
5-2 How to replace PCB
16
5-3 How to replace EEPROM with EEPROM included in PCB service pack
17
18
5-4 Table of settings
19
6. SERVICE PROCEDURE
6-1 Meaning of alarm message
20
6-2 Led indicator messages on outdoor control PCB
21
6-3 Symtoms and parts to inspect
22
6-4 Details of alarm messages
resistance
23
24
25
26
7. OUTDOOR UNIT MAINTENANCE REMOTE CONTROL
27
28
29
30
31
32
33
34
R.D. 28 Reyrieux BP 131 - 01601 Trévoux CEDEX France
Tél. 04.74.00.92.92 - Fax 04.74.00.42.00
R.C.S. Bourg-en-Bresse B 759 200 728