Download SFE-EV - Blaulain
Transcript
SFE-EV and buttons to change control Duration of chlorine cell control. Press duration. The maximum duration that can be set is equal to that defined for stage 2C. The option is displayed only if CL On. and buttons to change the duration of the Holliday function. Press the interval (in days) before the holliday function is activated. (this function can be set also by acceding with user password) The option is displayed only if SH: 2 or SH: 3. Duration 2C 1 – 2C OFF OFF-99 Average flow rate correction factor: 0 When the controller is programmed for a volumetric delayed control mode (SH2), then it calculates the remaining treatable volume and compares this value to the registered average flow rate added with the Po percentage to see if it can run one more day or not. When the controller is programmed for a volumetric immediate regeneration, then if the refill first option is activated (Pr 0), the controller will refill the brine tank before the regeneration starts based upon the time t programmed before. The controller compares the remaining treatable volume with the average flow rate corrected by this Po factor and determines if it is time to start refilling the brine tank to have the t time for brine formation after refill. In volumetric immediate mode, this factor has no influence if the refill first option is desactivated (Pr 1). To set up this factor use the up and down arrow and push the regeneration button to confirm. The option is displayed only if SH: 2 and SH: 3. Number of regenerations before the salt alarm to light up on the controller’s display. 10 0 – 99 00 – 99 Press and buttons to adjust and press the regeneration button to confirm. This option is displayed only if the salt sensor is not installed Calendar override for regeneration initiation: maximum number of days between 2 regenerations. In case no regeneration occurred during this programmed interval of day, the SFE-EV controller will automatically start a regeneration. Press 4 OFF – 14 0 0–1 14.0 00 – 99.9 and buttons to change. N.B.: This type of regeneration is carried out at the regeneration time even on nonenabled days. and buttons to change. 0=prescaler Prescaler flag (free/preset). Press free 1=prescaler with programmed values The option is displayed only if SH: 2 or SH: 3. Prescaler free for volumetric sensor. Set value (default equal to 14, applies to SIATA turbine with only one magnet). Press The option is displayed only if SP: 0 53 and buttons to change. E N G L I S H