Download UNIT 2 - Harken

Transcript
Preassembly
How many foils and connectors • Stringing connectors
Pin-to-Pin Headstay Length (See Pg 8)
Number 9" (229 mm) Connectors
39’2" to 40’1" (11.938 m to 12.217 m)
5
40’2" to 47’1" (12.243 m to 14.351 m)
6
47’2" to 54’1" (14.376 m to 16.485 m)
7
54’2" to 61’1" (16.510 m to 18.618 m)
8
61’2" to 67’2" (18.644 m to 20.472 m)
9*
Longueur axe à axe de l’étai (Voir Pg 8)
Bolzen-Bolzen-Mass Anzahl des Vorstages (s.S. 8)
Lunghezza perno-a-perno dello strallo (vedi p. 8)
Nombre de connecteurs de 229 mm utilisés
Verbindungselements
Numero di estrusi da 229 mm usati
■ How Many Connectors?
Use the chart at left to determine the proper number
of 9" (229 mm) connectors for your headstay.
Every unit uses one 11" (280 mm) bottom connector
in addition to the number of 9" (229 mm) connectors
shown at left.
*One additional connector required; order part 899
Number 7’ (2.13 m)Foils Used
Nombre de profils de 2.13 m utilisés
Verbindungselements
Numero di estrusi da 2.13 m usati
39’2" to 46’2" (11.938 m to 14.072 m)
5
46’3" to 53’2" (14.097 m to 16.205 m)
6
53’3" to 60’2" (16.231 m to 18.339 m)
7
60’3" to 67’2" (18.364 m to 20.472 m)
8*
■ How Many Foils?
Use the chart at left to determine the proper number of
7' (2.13 m) foils for your headstay.
The variable length top foil is cut from one of the 7'
(2.13 m) foils and is used in addition to the number of
foils shown at left.
*One additional foil required; order part 897
■ Stringing Connectors
After the headstay has been cut to length, but before the
lower terminal is attached, the proper number of connectors must be placed on the headstay in the correct
order.
Every unit uses a top foil trim cap.
Every unit uses a number of 9" (229 mm) connetors
which varies according to the length of the headstay
and is determined by consulting the chart above.
Every unit uses one 11" (280 mm) bottom connector
Slide the trim cap onto the stay so that the open end
faces down.
Slide the proper number of 9" (229 mm) connectors
onto the headstay.
Slide the 11" (280 mm) bottom connector onto the
headstay so that it is closest to the bottom of the headstay.
Have the wire swaged by a reputable rigger.
Norseman/Sta-Lok Instructions
Rod Instructions
Because Norseman and Sta-Lok terminals are applied to the
headstay wire after the foil is built, it is not necessary to place
the connectors or trim cap on the wire at this time.
Rod installations are identical to swaged wire at this point
except that the rod fitting is "coldheaded" to the rod rather than
swaged on.
Norseman and Sta-Lok units require the same number of foils
and connectors as shown above. Identify the parts you need
and set them aside at this time.
If you ship a rod headstay to a service center do not coil tighter
than 200 times the rod's diameter.
January 1999
Unit 2 MKIII
11