Download PROMATIC
Transcript
The LED 1 and LED 2 indicator lights should be green. If one or both of them is/are red, there is a problem (see table below). PRODUCTION DISPLAY LED 1 LED 2 HOVERS AROUND 100 GREEN GREEN Everything working normally. GREEN RED MEANING / CORRECTIVE ACTION IF REQUIRED 4) Water salinity too low. Check salinity and add 1 kg of salt per m3 of water in the pool. (minimum salinity = 4 g/l). 5) The cell is encrusted with scale and needs cleaning. 6) Water temperature too low (below 20ºC). Switch to “WINTER MODE” (button on the front face of the unit). RED RED 6) Add salt to the 3 (1 kg per m of water). pool 7) The cell is encrusted with scale and needs cleaning. 8) Water temperature too low (below 20ºC). Switch to “WINTER MODE” (button on the front face of the unit). 9) Check to make sure there is no air in the cell. If there is, the luminous Flow dot lights up (see “other indications”). N.B.: In “WINTER MODE” the unit works in the same way, the only difference being the reading given by the production display, which hovers around 85 instead of 100 (normal mode value).