8. Norms for rack mounting (max. 35 DVBS2-COFDM T0X - 7 subracks with 5 units in height - 8,7”)
8.1. Installation of the rack with
ventilation facilities
To facilitate the renewal and circulation of the
air inside the rack, and the temperature of the
units and thus improve their characteristics, it
is advisable to place 2 ventilation units of 25W,
particularly when the rack with the DVBS2-COFDM
T0X is located in warm place, with a temperature
higher than 40°C.
These ventilators will be placed on a tray, that is
screwed onto the top part of the Rack, fig. 1 and
2, and in this way the ventilators will be able to
extract the air from the DVBS2-COFDM T0X and
will be able to expel it via the gap (approx. 3-5 cm)
at the top part of the Rack. The air will enter again
through the lower part of the device, fig 3.