Download EiKO Global, LLC.
Transcript
WARNING - Risk of fire or electric shock. Install this kit only in the luminaires that has the construction features and dimensions shown in the photographs and/or drawings. WARNING - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. “The end retrofit luminaire has been modified and can no longer operate the originally intended lamp.” WARNING - Risk of fire or electric shock. Do not use this retrofit kit in luminaires employing shunted bi-pin lampholders。“ “Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components”. WARNING - Fig.1 means “DOUBLE INSULATION”。 Fig. 1 “Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.” THE RETROFIT ASSEMBLY IS ACCEPTED AS A COMPONENT OF A FLUORESCENT LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. “Has been evaluated for use with ceiling luminaires and type IC recessed luminaires where the lamps can be totally enclosed (i.e. Can be installed in luminaires with a diffuser)”. II