Download Terminadora de firmes

Transcript
Código
de fallo y
luz de advertencia
PID(P)
SID(S)
FMI
111*
YELLOW
S254
12
115*
YELLOW
SPN
(S)
FMI
Causa
Efectos
629
12
ECM internal hardware error.
Possible no effect or engine may run
rough or not start.
P190
2
190
2
No engine speed or position signal
detected at pin 17 of the engine harness.
Engine power derate.
Possible white smoke.
122
YELLOW
P102
3
102
3
High voltage detected at the boost
pressure sensor signal pin 45 of the
engine harness.
Engine will derate to no-boost fueling.
123
YELLOW
P102
4
102
4
Low voltage detected at boost pressuresensor signal pin45oftheengine
harness.
Engine will derate to no-boost fueling.
131
YELLOW
P091
3
091
3
High voltage detected at throttle position signal pin 30 of the OEM harness.
Engine idles when idle validation switch
indicates idle and ramps up to a default
set speed when the idle validation switch
indicates off-idle.
132
YELLOW
P091
4
091
4
Low voltage detected at throttle position signal pin 30 of the OEM harness.
Engine idles when idle validation switch
indicates idle and ramps up to a default
set speed when the idle validation switch
indicates off-idle.
133
YELLOW
P029
3
029
3
High voltage detected at remote throttle position signal pin 9 of the OEM
harness.
Engine will not respond to remote throttle
input.
134
YELLOW
P029
4
029
4
Low voltage detected at remote throttle position signal pin 9 of the OEM
harness.
Engine will not respond to remote throttle
input.
135
YELLOW
P100
3
100
3
High voltage detected at oil pressure
signal pin 33 of the engine harness.
Default value used for oil pressure.
No engine protection for oil pressure.
141
YELLOW
P100
4
100
4
Low voltage detected at oil pressure
signal pin 33 of the engine harness.
Default value used for oil pressure.
No engine protection for oil pressure.
143
YELLOW
P100
1
100
1
Oil pressure signal indicates oil pressure below the low minimum engine
protection limit.
Power derate and possible engine
shutdown if engine protection shutdown
feature enabled.
144
YELLOW
P110
3
110
3
High voltage detected at coolant temperature signal pin 23 of the engine
harness.
Default value used for coolant temperature.
No engine protection for coolant temperature.
145
YELLOW
P110
4
110
4
Low voltage detected at coolant temperature signal pin 23 of the engine
harness.
Default value used for coolant temperature.
No engine protection for coolant temperature.
D 56
D F181C.E 56-70 - 02-0103
Códigos de error