Download Terminadora de firmes
Transcript
Código de fallo y luz de advertencia PID(P) SID(S) FMI 111* YELLOW S254 12 115* YELLOW SPN (S) FMI Causa Efectos 629 12 ECM internal hardware error. Possible no effect or engine may run rough or not start. P190 2 190 2 No engine speed or position signal detected at pin 17 of the engine harness. Engine power derate. Possible white smoke. 122 YELLOW P102 3 102 3 High voltage detected at the boost pressure sensor signal pin 45 of the engine harness. Engine will derate to no-boost fueling. 123 YELLOW P102 4 102 4 Low voltage detected at boost pressuresensor signal pin45oftheengine harness. Engine will derate to no-boost fueling. 131 YELLOW P091 3 091 3 High voltage detected at throttle position signal pin 30 of the OEM harness. Engine idles when idle validation switch indicates idle and ramps up to a default set speed when the idle validation switch indicates off-idle. 132 YELLOW P091 4 091 4 Low voltage detected at throttle position signal pin 30 of the OEM harness. Engine idles when idle validation switch indicates idle and ramps up to a default set speed when the idle validation switch indicates off-idle. 133 YELLOW P029 3 029 3 High voltage detected at remote throttle position signal pin 9 of the OEM harness. Engine will not respond to remote throttle input. 134 YELLOW P029 4 029 4 Low voltage detected at remote throttle position signal pin 9 of the OEM harness. Engine will not respond to remote throttle input. 135 YELLOW P100 3 100 3 High voltage detected at oil pressure signal pin 33 of the engine harness. Default value used for oil pressure. No engine protection for oil pressure. 141 YELLOW P100 4 100 4 Low voltage detected at oil pressure signal pin 33 of the engine harness. Default value used for oil pressure. No engine protection for oil pressure. 143 YELLOW P100 1 100 1 Oil pressure signal indicates oil pressure below the low minimum engine protection limit. Power derate and possible engine shutdown if engine protection shutdown feature enabled. 144 YELLOW P110 3 110 3 High voltage detected at coolant temperature signal pin 23 of the engine harness. Default value used for coolant temperature. No engine protection for coolant temperature. 145 YELLOW P110 4 110 4 Low voltage detected at coolant temperature signal pin 23 of the engine harness. Default value used for coolant temperature. No engine protection for coolant temperature. D 56 D F181C.E 56-70 - 02-0103 Códigos de error