Download HEG-SERIES - Mi-T
Transcript
PREPARATION attire: Proper attire is essential to your safety. It is advised to utilize whatever means necessary to protect eyes, ears, and skin. Additional safety attire (such as respiratory mask) may be required when using detergent cleaning agents with this pressure washer. danger RISK OF EXPLOSION OR FIRE! SMELL FOR GAS BEFORE STARTING UNIT. ALWAYS SNIFF AREA AROUND THE MACHINE FOR A GAS SMELL. BE SURE TO SNIFF FLOOR AREA, SINCE SOME GAS IS HEAVIER THAN AIR AND WILL SETTLE ON THE FLOOR. IF YOU SMELL GAS: •DO NOT START UNIT. •DO NOT OPERATE ANY ELECTRICAL SWITCH. •DO NOT LIGHT ANY APPLIANCE. •DO NOT USE ANY PHONE IN THE ROOM OR AREA. •LEAVE, GO TO ANOTHER LOCATION AND USE A PHONE TO CALL YOUR GAS SUPPLIER. •FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS. •IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT. PRE-START: 1. Before lighting, smell all around the machine for gas. Especially, sniff the floor area because some gas is heavier than air and will settle on the floor. Do not operate unit if smell exists. Leave the location and contact a qualified serviceman. 2. Check to ensure the voltage is on. 3. Pump oil level should be checked before each use. Check the oil level with the dipstick on top of the pump crankcase. (See illustration #13.) The proper oil level should be at the notch on the dipstick. If the level appears low, use pump oil SAE20 or 30 non-detergent. ILLUSTRATION #13 PUMP-REAR OIL GAUGE unloader: The unloader has been preset at the factory and should only be adjusted by a trained serviceman. Operator's Manual 21