Download instructions d`installation
Transcript
SETTING THE BURNER MINIMUM When switching from one type of gas to another, the minimum flow rate must also be correct: the flame should not go out even when passing suddenly from maximum to minimum flame. To regulate the flame follow the instructions below: Rapid - and triple ring burners Light the burner Set the gas valve to LO position Remove the knob With a thin screwdriver pass by the hole of microswitch adjustment is correct (fig. 2.7). o o and turn the screw F until Fig. 2.7 Inside crown of DUAL burner - Light the DUAL burner Set the gas valve toS_ position Remove the knob Using a screwdriver turn the screw H until the correct setting is obtained (fig. 2.8). H G Outside crowns of DUAL burner - Light the DUAL burner Set the gas valve to position - Remove the knob - Using a screwdriver turn the screw G until the correct setting is obtained (fig. 2.8). For LP/PROPANE gas, tighten the adjustment screws completely. Fig. 2.8 21