BUILT-IN UNIT OPENING DIMENSIONS A SMALL ACCESS HOLE IS REQUIRED TO RUN WIRE FROM LED (LIGHTS) DOWN INTO CAVITY OF CABINET. BATTERY PACK MUST BE MOUNTED A MINIMUM OF 20cm BELOW BOTTOM OF GRILL TO PREVENT MODULE FROM OVER HEATING. ENSURE WIRES AND MODULE DO NOT INTERFERE WITH DRIPPAN REMOVAL OR COME IN CONTACT WITH BOTTOM OF GRILL. OUTDOOR GFI ELECTRICAL OUTLET RECOMMENDED - LOCATE ON LEFT SIDE OF GRILL FOR ROTISSERIE USE. GAS INLET OPENING BUILT-IN SIDEBURNER W D H 4.5cm D H 15.5c 4.5cm m GAS INLET OPENING W 86.5cm RECOMMENDED ATER M E L STIB U B -COM NON IAL MINIMUM 65cm2 OF VENTILATION REQUIRED ON EACH END OF CABINET CABINET FRAME AND CABINET MUST BE MADE FROM NON-COMBUSTIBLE MATERIAL MODEL OPENING DIMENSIONS W D NOTES H BIM485 75.5cm 54.5cm 19cm BIM605 93cm 54.5cm 19cm BIM730 110cm 54.5cm 19cm SIDE BURNER 34.5cm 44.5cm 10cm Opening of at least 32cm2 in must be provided for combustion air for side burner.