Download MPA-CPI-VI

Transcript
MPA-CPI-VI
Valve Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . en
1 Function
Valve terminals are configurable function units for controlling
complex pneumatic drive systems.
The electrical and logic supplies to the valves are made via
the CPI string. The left-hand end plate, the pneumatic interface and the CPI module form a unit.
(with Order code 56E-…-EX1E)
II 3G Ex nA IIC T4 X Gc
MPA
VMPA-CPI-EPL-...
(de) Spezialdokumentation ATEX
(en) Special documentation ATEX
(sv) Särskild dokumentation ATEX
(es) Documentación especial ATEX
(fr) Documentation spéciale ATEX
(it) Documentazione speciale ATEX
Festo AG & Co. KG
Postfach
D-73726 Esslingen
Phone:
+49/711/347-0
www.festo.com
Original: de
1206NH
8005181
......................................................
Note
– Detailed specifications on the product and accessories
intended, the manual and the conformity declaration can
be found in Internet:www.festo.com
– Technical specifications on the product may show different values in other documents. The technical specifications in this document always apply when operating in
an explosive atmosphere.
– Fitting and commissioning to be carried out only by qualified personnel in accordance with manual.
Product identification
Example of manufacturing period C6 = June 2012
2 Application
• The valve terminal has been designed for controlling pneumatic actuators.
• The VMPA-CPI-EPL-... interface is intended as the interface
to the higher-order controller.
• Operate the device only with compressed air of at least
quality class [7:4:4] to ISO 8573-1:2010.
Note on the operating medium: Lubricated operation not
permissible.
• The device is not intended for use with other fluids.
• Always generate compressed air and vacuum outside the
potentially-explosive range.
• The device can be used under the specified operating conditions in zone 2 of potentially explosive gas atmospheres.
..........................................
If labelled with X: special conditions
• Fit the device into a housing with at least IP54
(corresponding to EN 60079-15).
• Do not disconnect or open under tension.
• Prevent separation of the plug connectors or housing
parts by using a housing with special lock (e.g. control
cabinet).
• Use additional strain relief for cables in front of every
plug.
• Use suitable installation measures to prevent electrostatic discharges on the housing.
• Ambient temperature –5 °C ≤ Ta ≤ +50 °C.
• Protect the device from ultra-violet radiation.
• Protect the device against all kinds of shock stress.
• The replacement of electronic modules and valve plates is
permitted. Use only approved components.
• Use the product in its original condition without undertaking any modifications. The right of use will be withdrawn if
modifications are made by the user.
3 Commissioning
................................................
MPA-CPI-VI
546280 C608
1:-X,X-XXbar
12,14:X-Xbar
II 3G
Ex nA IIC T4 X Gc
Warning
The discharge of electrostatically charged parts can lead
to sparks which can cause an explosion.
• Prevent electrostatic discharges by means of suitable
installation and cleaning measures.
• Include the device in the potential equalization of the
system.
......................................................
Manufacturing year
X = 2009
F = 2015
A = 2010
H = 2016
B = 2011
J = 2017
Manufacturing month
1
2
3
4
5
6
7
8
9
O
N
D
January
February
March
April
May
June
July
August
September
October
November
December
C = 2012
K = 2018
D = 2013
L = 2019
Note
E = 2014
M = ...
6 Accessories
Approved components MPA-CPI-VI
Electrical connection
Housing module
Electronic modules
Electronic module
Electrical manifold module
4 Operation
Warning
Electrically produced sparks may ignite a potentially explosive atmosphere.
• Do not disconnect or open under tension.
• Note the operating conditions and the specifications in the
manual.
• Always observe the maximum permitted limits.
5 Service and maintenance
• Carry out service and maintenance only outside potentially
explosive areas.
• Check at regular intervals to ensure that the product
functions correctly.
Malfunctioning
Remedy
Audible leakage
1. Check the screw connectors or
2. Replace the valve circuits affected.
• Wearing parts and spare parts can be replaced in
individual cases. Repairs of this nature may only be undertaken by qualified and authorized personnel.
Please contact a specialist from Festo.
546983
546984
546985
546986
703648
703649
703650
703651
VMPA1-FB-EMS-8
VMPA1-FB-EMG-8
VMPA2-FB-EMS-4
VMPA2-FB-EMG-4
VMPA1-FB-EV-AB
VMPA1-FB-EV-V
533360
533361
537983
537984
537998
537999
VMPA-APU
VMPA-AP
VMPA-AP-3/8
Flat seal
MPA
Separator seals for ducted exhaust
Seal
VMPA1-DPU
VMPA1-DPU-P
VMPA1-DPU-RS
VMPA1-DPU-PRS
VMPA1-DP
VMPA1-DP-P
VMPA1-DP-RS
VMPA1-DP-PRS
Sub-bases
Sub-base
VMPA1-FB-AP-4-1
VMPA1-FB-AP-4-1-T1
VMPA1-FB-AP-4-1-S1
VMPA2-FB-AP-2-1
VMPA2-FB-AP-2-1-T0
VMPA2-FB-AP-2-1-S0
Electrical supply plates
Supply plate
VMPA-FB-SP-V
VMPA-FB-SP-7/8-V-5POL
VMPA-FB-SP-7/8-V-4POL
Pneumatic supply modules
Supply plate
VMPA1-FB-SPU
VMPA1-FB-SP
End plates
End plate
VMPA-EPR
533374
533375
541629
659481
533355
533356
533357
533358
533359
533363
533364
533365
533352
538657
555901
538000
538677
555902
541082
541083
541084
533353
533354
533373
Approved valve components
Solenoid valve VMPA1
Solenoid valve VMPA2
Cover plate
Pneumatic accessories
Cap
Identification plates
......................................
VMPA-CPI-EPL-E
VMPA-CPI-EPL-G
VMPA-CPI-EPL-EU
VMPA-CPI-EPL-GU
MPA-CPI-VI-S
MPA-CPI-VI-T
MPA-CPI-VI-V
MPA-CPI-VI-X
Pneumatic linking
Plate (silencer)
Base (exhaust)
Note
Escaping exhaust air can whirl up dust deposits and provoke a potentially explosive dust atmosphere.
• Observe the specifications on the rating plate.
• Comply with applicable national and international
guidelines.
• After maximum 3 pneumatic sub-bases insert an electric
supply plate.
• Then use maximum 4 pneumatic sub-bases per electric
supply plate.
• Always use electronic modules VMPA...-FB-EMG-... to the
right next to the supply plate.
• Earth all supply voltages.
• Limit the switching frequency to max. 10 Hz.
With switching frequencies higher than 2 Hz:
Maintain a pause ratio of at least 50%.
• Provide for the removal of the internal heat. The surface of
the solenoid coil must not be covered.
• Use only approved components.
7 Technical specifications
General operating conditions
Mounting
VMPA1-M1H-M-PI
VMPA1-M1H-J-PI
VMPA1-M1H-B-PI
VMPA1-M1H-G-PI
VMPA1-M1H-E-PI
VMPA1-M1H-K-PI
VMPA1-M1H-N-PI
VMPA1-M1H-H-PI
VMPA1-M1H-D-PI
VMPA1-M1H-X-PI
VMPA1-M1H-W-PI
VMPA1-M1H-I-PI
VMPA2-M1H-M-PI
VMPA2-M1H-J-PI
VMPA2-M1H-B-PI
VMPA2-M1H-G-PI
VMPA2-M1H-E-PI
VMPA2-M1H-K-PI
VMPA2-M1H-N-PI
VMPA2-M1H-H-PI
VMPA2-M1H-D-PI
VMPA2-M1H-X-PI
VMPA2-M1H-W-PI
VMPA2-M1H-I-PI
VMPA1-RP
VMPA2-RP
533342
533343
533344
533345
533346
533347
533348
533349
533350
534415
540050
543605
537952
537953
537954
537955
537956
537957
537958
537959
537960
537961
540051
543703
533351
537962
MH1
MH1 GESCHL.
MPA-...
VMPA1-ST-2-4
CPA-BG-NRH
VMPA-BG-RW
693160
693159
697453
698382
173498
534416
Max. operating pressure
Max. control pressure
Ambient temperature
Medium temperature
Operating medium
Rated operating voltage DC
Max. switching frequency
Max. pulse ratio at >2 Hz
Safety class
Degree of contamination
Protection class
Tightening torque
Earthing screw
Sub-base
Cover screw
Mounting position
Materials
Housing
Seals
10 bar
8 bar
–5 ... +50 °C
–5 ... +50 °C
Compressed air to ISO 8573-1:2010:
[7:4:4].
Lubricated operation not possible.
24 V ± 25 %
10 Hz
50 %
III (PELV) as per EN 61140
2
IP20 as per EN 60529
1.3 Nm ± 20 %
1.8 Nm ± 10 %
0.65 Nm ± 10 %
– any
– with H-rail mounting only horizontal
All aluminium alloys used contain less
than 7.5 % magnesium (Mg) by mass.
Elastomer, NBR