MPA(F)-MPM-VI
Valve Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . en
1 Approved valve terminals
Type
(with Order code 32E(33E)-…-EX1E)
II 3G Ex nA IIC T4 X Gc
Solenoid valve VMPA1
Part No.
MPA-MPM-VI mit Bestellcode1: 32E-...-EX2
MPAF-MPM-VI mit Bestellcode1: 33E-...-EX2
7 Accessories
Approved components
539105
544398
2 Function
Valve terminals are configurable function units for controlling
complex pneumatic drive systems.
The valve terminal contains, amongst other things, valve subbases with 5/2-, 3/2- or 2/2-way valves.
The electrical connection is made via a SUB-D multipin plug.
The pneumatic connection is made via the supply module.
Solenoid valve VMPA2
(de) Spezialdokumentation ATEX
(en) Special documentation ATEX
(sv) Särskild dokumentation ATEX
(es) Documentación especial ATEX
(fr) Documentation spéciale ATEX
(it) Documentazione speciale ATEX
Festo AG & Co. KG
Postfach
D-73726 Esslingen
Phone:
+49/711/347-0
www.festo.com
3 Application
• The valve terminal has been designed for controlling pneumatic actuators.
• Operate the device only with compressed air of at least
quality class [7:4:4] to ISO 8573-1:2010.
Note on the operating medium: Lubricated operation not
permissible.
• The device is not intended for use with other fluids.
• Always generate compressed air and vacuum outside the
potentially-explosive range.
• The device can be used under the specified operating conditions in zone 2 of potentially explosive gas atmospheres.
Original: de
..........................................
1206NH
8005097
......................................................
Note
– Detailed specifications on the product and accessories
intended, the manual and the conformity declaration can
be found in Internet:www.festo.com
– Technical specifications on the product may show different values in other documents. The technical specifications in this document always apply when operating in
an explosive atmosphere.
– Fitting and commissioning to be carried out only by qualified personnel in accordance with manual.
Product identification
Example of manufacturing period C6 = June 2012
Sub-bases without
electrical linking
Note
If labelled with X: special conditions
• Fit the device into a housing with at least IP54
(corresponding to EN 60079-15).
• Do not disconnect or open under tension.
• Prevent separation of the plug connectors or housing
parts by using a housing with special lock (e.g. control
cabinet).
• Use additional strain relief for cables in front of every
plug.
• Use suitable installation measures to prevent electrostatic discharges on the housing.
• Ambient temperature –5 °C ≤ Ta ≤ +50 °C.
• Protect the device from ultra-violet radiation.
• Protect the device against all kinds of shock stress.
• Conversion and replacement of valve plates is permitted.
Use only approved components and intended accessories.
• Use the product in its original condition without undertaking any modifications. The right of use will be withdrawn if
modifications are made by the user.
Sub-bases with electrical
linking and electronic module
End plate right side
Electronics module
4 Commissioning
Electrical manifold
................................................
MPA-MPM-VI
539105 C608
1:-X,X-XXbar
12,14:X-Xbar
II 3G
Ex nA IIC T4 X Gc
Warning
The discharge of electrostatically charged parts can lead
to sparks which can cause an explosion.
• Prevent electrostatic discharges by means of suitable
installation and cleaning measures.
• Include the device in the potential equalization of the
system.
Electrical interface
Manufacturing year
X = 2009
F = 2015
A = 2010
H = 2016
B = 2011
J = 2017
Manufacturing month
1
2
3
4
5
6
7
8
9
O
N
D
January
February
March
April
May
June
July
August
September
October
November
December
C = 2012
K = 2018
D = 2013
L = 2019
E = 2014
M = ...
......................................................
Note
Escaping exhaust air can whirl up dust deposits and provoke a potentially explosive dust atmosphere.
• Observe the specifications on the rating plate.
• Comply with applicable national and international
guidelines.
• Earth all supply voltages.
• Limit the switching frequency to 10 Hz with a pulse ratio of
50%.
• Provide for the removal of the internal heat. The surface of
the solenoid coil must not be covered.
• Use only approved components.
Cover plate
Manual override
Cover cap
Exhaust plate
5 Operation
......................................
Warning
Electrically produced sparks may ignite a potentially explosive atmosphere.
• Do not disconnect or open under tension.
• Note the operating conditions and the specifications in the
manual.
• Always observe the maximum permitted limits.
Supply plate
Power supply module
Seals for connection block
Separating seal for ducted
exhaust
6 Service and maintenance
• The devices are maintenance-free.
• Check at regular intervals to ensure that the product
functions correctly.
Malfunctioning
Remedy
Audible leakage
1. Check the screw connectors or
2. Replace the valve circuits affected.
• Wearing parts and spare parts can be replaced in
individual cases. Repairs of this nature may only be undertaken by qualified and authorized personnel.
Please contact a specialist from Festo.
Separating seal for flat
plate silencer
Plug with multipin cable
Hood
Connecting cable PVC
Connecting cable PUR
Part-No.
VMPA1-M1H-M-PI
VMPA1-M1H-J-PI
VMPA1-M1H-B-PI
VMPA1-M1H-G-PI
VMPA1-M1H-E-PI
VMPA1-M1H-K-PI
VMPA1-M1H-N-PI
VMPA1-M1H-H-PI
VMPA1-M1H-D-PI
VMPA1-M1H-X-PI
VMPA1-M1H-W-PI
VMPA1-M1H-I-PI
VMPA2-M1H-M-PI
VMPA2-M1H-J-PI
VMPA2-M1H-B-PI
VMPA2-M1H-G-PI
VMPA2-M1H-E-PI
VMPA2-M1H-K-PI
VMPA2-M1H-N-PI
VMPA2-M1H-H-PI
VMPA2-M1H-D-PI
VMPA2-M1H-X-PI
VMPA2-M1H-W-PI
VMPA2-M1H-I-PI
VMPA1-FB-AP-4-1
VMPA2-FB-AP-2-1
VMPA1-FB-AP-4-1-T1
VMPA2-FB-AP-2-1-TO
VMPA1-FB-AP-4-1-S1
VMPA2-FB-AP-2-1-S0
VMPAF-AP-2-2
VMPAF-AP-2-2-T0
VMPAF-AP-4-1
VMPAF-AP-4-1-T1
VMPA1-AP-4-1-EMM-8
VMPA2-AP-2-1-EMM-4
VMPA1-AP-4-1-EMM-4
VMPA2-AP-2-1-EMM-2
VMPAF-AP-2-1-EMM-2
VMPAF-AP-2-1-EMM-4
VMPAF-AP-4-1-EMM-4
VMPAF-AP-4-1-EMM-8
VMPA-EPR
VMPAF-EPR
VMPA2-MPM-EMM-2
VMPA2-MPM-EMM-4
VMPA1-MPM-EMM-4
VMPA1-MPM-EMM-8
VMPA1-MPM-EV-AB-4
VMPA1-MPM-EV-AB-8
VMPA1-MPM-EV-ABV-4
VMPA1-MPM-EV-ABV-8
VMPA2-MPM-EV-AB-2
VMPA2-MPM-EV-ABV-2
VMPAF-MPM-EV-AP-2
VMPAF-MPM-EV-AP-4
VMPAF-MPM-EV-AP-8
VMPAF-MPM-EV-SP
VMPA1-MPM-EPL-G
VMPA1-MPM-EPL-E
VMPA1-MPM-EPL-GU
VMPA1-MPM-EPL-EU
VMPAF-MPM-EPL
VMPAF-MPM-EPL-AP-1
VMPAF-MPM-EPL-APU
VMPA1-RP
VMPA2-RP
VMPA1-HBT
VMPA1-HBV
VMPA-HBT-B
VMPA-HBV-B
VMPA-APU
VMPA-AP
VMPAF-AP-1
VMPAF-AP-2
VMPAF-APU
VMPA1-FB-SPU
VMPA1-FB-SP
VMPAF-MPM-SP-P-APU
VMPAF-MPM-SP-P-AP-1
VMPAF-SP-P
VMPAF-SP-E
533342
533343
533344
533345
533346
533347
533348
533349
533350
534415
540050
543605
537952
537953
537954
537955
537956
537957
537958
537959
537960
537961
540051
543703
533352
538000
538657
538677
555901
555902
544403
547505
544402
547504
546804
546805
546806
546807
547497
547495
547496
547494
533373
544401
537985
537986
537987
537988
537993
537994
537995
537996
537989
537991
544413
544414
544415
544416
540894
540893
540896
540895
544400
547511
547510
533351
537962
533366
535257
540897
540898
533374
533375
544411
544412
544410
533353
533354
547514
547515
544404
544405
VMPA1-DP
VMPA1-DP-P
VMPA1-DP-RS
VMPA1-DP-PRS
VMPAF-DP
VMPAF-DP-P
VMPAF-DP-PRS
VMPAF-DP-RS
VMPA1-DPU
VMPA1-DPU-P
VMPA1-DPU-RS
VMPA1-DPU-PRS
533359
533363
533364
533365
544406
544407
544409
544408
533355
533356
533357
533358
VMPA-KMS-H
VMPA-KMS1-24-2,5
VMPA-KMS1-24-5
VMPA-KMS1-24-10
VMPA-KMS1-8-2,5
VMPA-KMS1-8-5
VMPA-KMS1-8-10
VMPA-KMS2-24-2,5-PUR
VMPA-KMS2-24-5-PUR
VMPA-KMS2-24-10-PUR
VMPA-KMS2-8-2,5-PUR
VMPA-KMS2-8-5-PUR
VMPA-KMS2-8-10-PUR
533198
533192
533193
533194
533195
533196
533197
533501
533502
533503
533504
533505
533506
Approved accessories
Mounting
Identification plates
Retainer
CPA-BG-NRH
VMPA-BG-RW
VMPAF-BG-RW
VMPAF-ST1
VMPAF-ST1T
VMPAF-STH
173498
534416
544420
544422
546228
544421
8 Technical specifications
General operating conditions
Max. operating pressure
Max. control pressure
Ambient temperature
Medium temperature
Operating medium
10 bar
8 bar
–5 ... +50 °C
–5 ... +50 °C
Compressed air to
ISO 8573-1:2010: [7:4:4].
Lubricated operation not possible.
Rated operating voltage DC
24 V ± 25 %
Max. switching frequency
10 Hz
Max. pulse ratio at >2 Hz
50 %
Safety class
III (PELV) as per EN 61140
Protection class
IP20 as per EN 60529
Degree of contamination
2
Grid interval of valve sub-bases  10 mm
Tightening torque
Multipin plug
0.65 Nm ± 20 %
Earthing screw
1.3 Nm ± 20 %
Mounting position
– any
– with H-rail mounting only horizontal
Materials
Housing
All aluminium alloys used contain
less than 7.5 % magnesium (Mg)
by mass.
Seals
Elastomer, NBR
Special operating conditions
Max. starting current / starting
duration
Max. holding current after starting duration
MPA1
MPA2
100 mA/25 ms
130 mA/50 ms
25 mA
25 mA