Download SE192K

Transcript
IST-2192.KM02.01/A
Istruzione / User’s Manual / Manuel d’utilisation
Pag. 6 / 6
Centraline collegabili a SE192KG e SE192KM
Detectors which can be connected to the SE192KG - SE192KM
Centrales raccordable au SE192KG - SE192KM
Modello/ Model / Modale
N°Sensori / Sensors number / nombre de sondes
SE127K - SE128K - SE139K
1
SE184K - SE194K
1÷3
Tab. A - SE192KG (GPL / LPG)
Uscita Output Sortie (mA)
% LIE / LEL
4
0
8
5
12
10
20
20
% v/v
0
0,075
0,15
0,3
Tab. B - SE192KM (Metano / Methane)
Uscita Output Sortie (mA) % LIE / LEL
% v/v
4
0
0
8
5
0,4
12
10
0,5
20
20
1
P1 – SPAN (20mA)
P2 – ZERO (4mA)
TP1+
mA
TC011
+ - S
0,3 L/min.
40÷200mV
TP24÷20mA
+ - S
Centralina Gas
Gas detector
Centrale de détection
Fig.1 Verifica / Test / Vérification
75
Fig.2 TC011 Tester di calibrazione
Calibration Tester / Tester d’étalonnage
Posizionamento
Positioning / Positionnement
GAS
SENSOR
IP44
110
72
37,5
37,5
82
Montaggio a parete
Wall-mounting / Montage au mur e
Fig. 3 - Dimensioni / Outline Dimensions / Dimensions
TECNOCONTROL S.r.l. Via Miglioli 47 SEGRATE ( MI )
Tel: 02/26 92 28 90 Fax: 02/21 33 734