Download bedienungsanweisung operating instructions - cie
Transcript
3.4.2.2 Selecting the protocol for communication with the keyboards Switch off the matrix by disconnecting the power supply jack • Remove the screws fastening down the cover and open the matrix, following the instructions in section 3.4.1 • Find and set the dip-switches according to the table below • Close the cover and fasten it with the screws • Connect the power supply jack to switch the matrix back on. Note: all changes to the dip-switches are recognised when the matrix is restarted Dip switch 1 2 OFF OFF OFF OFF OFF OFF OFF OFF 3 OFF OFF ON ON 4 OFF ON OFF ON Protocol and baud rate Macro, 38400 baud (*) Macro, 19200 baud Macro, 9600 baud Macro, 1200 baud Connected keyboards KS KBJ, KS KBK (*) Default configuration 3.4.3 Inserting th e load on the AUX line To insert/disconnect the 120 Ohm load on the RS485 AUX line, position jumper JP11 as shown in the diagram: Jumper JP11 with load connected (position A) Jumper JP11 with load disconnected (position B) 3.4.4 Setting 75 O hm video input termination It’s possible to remove the 75 Ohm video input termination putting the corresponding jumper into position B. Example: input 1-2-3 without load Pag. 10 MNECKSVM164_0350