Download Easy
Transcript
Display Default Menu SER (OD 1 SR.P 1 BAV 4 PAR 0 S.IN 0 S.0V 0 S.UI 0 Menu INP SP.R 0 TYP 0 FLT 0.1 FLD 0.5 DP.S 0 LO.S 0 Ki.S 1000 OFS 0 FT.2 0.1 LS.2 0.0 KS.2 100.0 0F.2 0.0 LO.L 0 Ki.L 1000 Menu 0VT A1.R 0 A2.R 0 A3.R 0 A1.T 0 A2.T 0 A3.T 0 KB.F 4 RL.1 2 RL.2 0 RL.3 3 RL.4 4 (T.1 20 (T.2 20 (T.3 20 (T.4 20 REL 0 AN.O 0 L.AN 0 K.AN 1000 Menu PRO PRO 0 Menu KRD KD.1 0 [TR 6 AL.N 1 BVT 0 DiG 0 Di2 0 DSP 0 LD.1 1 LD.2 10 LD.3 20 CONF Acronym Description Instrument Code Serial Protocol bAudrate PArity S. Input S. Output S. User Interface Instrument identification code Serial interface protocol Baudrate selection Parity selection Virtual instrument inputs Virtual instrument outputs Virtual instrument user interface SetPoint remote type of Probe FiLter FiLter display dot Position Scale Low Scale High Scale oFfSet Filter 2 Limit Scale 2 High Scale 2 OFfset 2 Low Limit High Limit Remote Setpoint Type of probe, signal, Linearization enabling etc. Digital filter on input Digital filter on display Decimal point position for input scale Minimum limit main input scale Maximum limit main input scale Offset correction of main input Auxiliary input digital filter Minimum limit auxiliary input scale Maximum limit auxiliary input scale Offset correction of auxiliary input Lower limit for setting SP and absolute alarms Upper limit for setting SP and absolute alarms Alarm 1 reference Alarm 2 reference Alarm 3 reference Alarm 1 type Alarm 2 type Alarm 3 type Hb Function reference Line 1 reference Line 2 reference Line 3 reference Line 4 Cycle time 1 Cycle time 2 Cycle time 3 Cycle time 4 alarm fault action Analogue output Low Analogue High Analogue Select reference value for alarm 1 Select reference value for alarm 2 Select reference value for alarm 3 Alarm 1 type Alarm 2 type Alarm 3 type HB alarm functions OUT 1 Reference signal allocation OUT 2 Reference signal allocation OUT 3 Reference signal allocation OUT 4 Reference signal allocation OUT 1 cycle time (+HEAT/-COOL) OUT 2 cycle time (+HEAT/-COOL) OUT 3 cycle time (+HEAT/-COOL) OUT 4 cycle time (+HEAT/-COOL) Alarms status in case of broken probe OUT W Signal or reference value allocation MIN scale for analog repetition output scale MAX scale for analog repetition output scale Protection Parameters access protection code Hardware 1 Control Alarm number button DiGital digital 2 diSPlay Led 1 Led 2 Led 3 Virtual instrument, led status and Multiset enabling Control type Enabled alarms number selection M/A key function Digital input 2 function 1 (0 ... 53) Digital input 2 function 2 (0 ... 53) SV Display function LED 1 function LED 2 function LED 3 function 80