Download Weighbridge cable junction box
Transcript
Cable junction boxes PR 6021/08, PR 6021/68 1. APPLICATION AND CONSTRUCTION CONSTRUCTION Cable junction boxes PR 6021/08, PR 6021/68 are designed especially for weighbridges: they include protection against overvoltages and corner-adjustment. 2. TECHNICAL DATA Protection class PR 6021/08 acc. to IEC 529 acc. to NEMA Mounting position Number of load cells Lightning / overvoltage protection Pressure equalization valve Junction box material Colour of junction box Weight net with packing Operating temperature Storage and transport Insulation resistances (max. 95% relative humidity , 100V DC) core - core core - screen core - housing Vibration resistance (acc. to IEC 68-2-6 Fc with 30g, 6h, all 3 axes) Resistance to irradiation (acc. to EN 61000-4-3) Test voltage (1 min.) Explosion protection (acc. to EN 50014 and EN 50020 resp. VDE 170/171 part 7) -K1 -K2 -K3 -K4 -K5 -K6 supply blue supply + red output - grey output + green screen of extension cable screens of load cell cables E-1 PR 6021/68 IP65 4X cable entries at bottom side 1…8 built-in (surge arrestors A81C90X) built-in polycarbonate stainless steel 1.4404, AISI316L, grey electro-polished 0.65 kg 1.4 kg 0.85 kg 1.5 kg -30°C...+70°C -40°C...+80°C ----- >1000M¥ >1000M¥ >1000M¥ yes yes yes --------- 500V AC yes