Download 取扱説明書 Resonance Mini DOAS Spectrometer Model # RMD I

Transcript
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 1 OF 22
RMDI system.doc
取扱説明書
Resonance Mini DOAS Spectrometer
Model # RMD I
April 12, 2004
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 2 OF 22
RMDI system.doc
目次
1. RMDI について............................................................................................................3
2. 機器の組立て及び設定...................................................................................................3
2.1
スキャナーの取り付けと操作 .............................................................................5
3 分光計の操作について .......................................................................................................5
3.1
分光計/スペクトル取りこみの機能の確認 .......................................................6
3-2
Resonance ソフトウエア-の操作.........................................................................7
Appendix 1. SPECTROMETER SPECIFICATIONS ...................................................9
Appendix 2: SPECTROMETER CALIBRATION ......................................................10
Appendix 3: Script File Listing........................................................................................11
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
1.
Operating Manual
Resonance Micro-DOAS RMDI
Page 3 OF 22
RMDI system.doc
RMDI について
RMDI は大気のガスのリモートセンシングのために設計された、コンパクトな UV/可視の分光計
システムです。これには小型の CCD アレーを使用した分光計(280∼420nm までのスペクトルをカ
バーする)を使用しています。さらにバックパッキング出来るほど小さく、火山の噴出ガス分析出
来る場所まで容易に持ち運べます。電源はラップトップコンピュータの USB から供給出来ます。
このシステムには、セルホルダーに、SO2 と NO2(SO2 または NO2)の較正用セル、ソフトウェ
アをインストールされたラップトップコンピューター、較正および小型の三脚が通常付属します。
分析ソフトウェアは、Ocean Optics OOIBase と互換性をもつ 1 つの"on line off line"スクリプトフ
ァイルを含んでいます。さらに、RMDI は、DOASIS(ハイデンベルグ大学からダウンロードする
ことができる)と互換性をもちます。表紙の図は、エクアドルの Tunguruhua 火山でラップトップ
コンピュータと RMDI 使用しているところを示しています。
RMDI の光学アッセンブリの構成部品を下の figure 3 に示します。
¼ in. x 20
tpi tripod
mounting
hole (are
present on
all four
faces)
Figure 3: Elements of the RMDI optical assembly
Scanner
motor
2.
Scanner
mirror
Cal cell
holder
Telescope
and filter
assembly
Spectrometer
assembly in
protective
case
機器の組立て及び設定
RMDI は任意の方向で使用でき、望遠鏡軸上の空を直接、あるいはオプションのスキャナー
を使用してその軸に対して直角に回転して見ることができます。分光計のケース(fig. 3)には 4
つの取りつけ穴が標準の軽量三脚に取りつけてあります。 光学スキャナは、観察方向を選択
するためにスキャナ・モータ/コントローラーを使用することができます。 この機器は、つま
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Page 4 OF 22
Operating Manual
Resonance Micro-DOAS RMDI
Electro-Optics Research,
Development and Manufacturing
RMDI system.doc
みで手動で調整するか、あるいは 120 度の角度で、自動的に反復して走査することができま
す。
Figure 4 RMDI component parts
13
14
12
9
1
11
3
10
8
2
4
7
6
5
Figure 4 に、RMDI システムの構成部品を示します。 右下から左側に順に説明します。(1)分
光計の保護ケース (2)Ocean Optics USB 2000 分光計 (3)分光計取りつけフランジ (4)望遠鏡
チューブ用のスペーサー (5)望遠鏡チューブ (6)C マウントホルダ中の望遠鏡レンズ、(7)、
C マウントホルダ中の UV カットフィルタ (8)較正セルホルダーおよびカバー (9)較正セル
(10)スキャンニングミラーアッセンブリ (11)パームトップコンピュータ用 CD ドライブ
figure 4 の最上部の列は(12)RMDI 用パームトップコンピューターAC 電源、(13)RMDI ミニ
三脚および(14)RMDI パームトップコンピューターを示しています。
RMDI 本体を、最初に、黒い後部捕虜ナットを備えた分光計上の保護ケースから分光計を慎
重に取り出します。テレスコープおよび較正用部品は、注意して、部品(5)(6)(7)および(8)をね
じで留めすることで組み立てることができます。次に、スペーサーリング(4)を置くことで、
分光計取りつけフランジ(3)に付けることができます。ネジを回していて、堅くなったり、噛
んだ場合、イソプロピルアルコールを 10 滴ほどたらすことで回るようになるはずです。毛細
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 5 OF 22
RMDI system.doc
管作用で液体がネジの間を満たした後ネジは抜ける様になると思います。ネジを回していて、
堅くなったり、噛んだ場合、イソプロピルアルコールを 10 滴ほどたらすことで回るようにな
るはずです。毛細管作用で液体がネジの間を満たした後ネジは抜ける様になると思います。
RMDI の向きによっては、測定セルホルダー(8)を回転させた方が良いかもしれません。その
結果セルスロットの面が上を向くかもしれません。スペーサーを、機器をこの方向で固定す
る為に取り付けることが出来ます(スペーサーは、標準の三脚上に取り付けた RMDI で、スロ
ットが上を向いた状態で固定するために提供されます)。スキャナアッセンブリとテレスコー
プがつながれれば、全体の RMDI を三脚に取り付けることができます。
RMDI の接続は、(1)コンピューターに付けた USB ケーブルを、RMDI 上の USB レセプタクルに
接続します。そして(2)スキャナコントローラーハンドモジュールに接続線を差し込みます。
2.1
スキャナーの取り付けと操作
スキャナは、120 度の角度をスキャンするのにかかる速度を、30 秒、1 分、2 分、4 分および 8 分
から選択できます。スキャナコントローラーの前面パネルを下に示します。
自動スキャン:
Manual
start
Cycle
time
Auto
Power
30 sec
RESONANCE
LTD.
Scanner
Controller
1.
2.
3.
4.
5.
6.
7.
manual/auto スイッチを auto にする
power スイッチを ON にする
cycle time ボタンで速度を設定する
選択したスキャン速度が LED で 表示される
スキャンをさせるために start ボタンを押す
スキャナーは動作を反復を始めます
スキャン速度を変更するために 電源スイッチ
を切り 1 から 6 の操作を行う
1 min
2 min
4 min
ミラー方向の手動設定:
manual/auto スイッチを manual にする
1
2
power スイッチを ON にする
ダイアルでミラーの方向を設定する
3
8 min
3 分光計の操作について
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 6 OF 22
RMDI system.doc
CCD 検出器を使用するためには、Ocean Optics のソフトウェアが必要です。ソフトウェアディス
クが供給される場合、セット・アップする必要があります。ソフトウェアがプリインストールさ
れる場合(また供給されたパスワード)、これは、ソフトウェアのダウンロードしセット・アップの
指示に従いインストールしてください。
3.1
分光計/スペクトル取りこみの機能の確認
RMDI の機能の確認:
1.
コンピューターおよび RMDI に RMDI USB ケーブルを差し込み、その後、Ocean Optics
OOIBase プログラムを起動します。このプログラムには、有用なヘルプファイル(操作の
マニュアルとして役立つ)が含まれています。約 1 分後に、プログラムはスペクトルを得
るための準備ができます。ソフトウェアマニュアルの指示に従ってください。簡潔に、1
つは(1)ウィンドウ(背景、参照あるいはサンプル)を選択する必要があります、(2)そしてサ
ンプリング時間および平均回数を設定します(3)、スペクトルを取りこみます。
動作しているかを迅速に確認する方法は、蛍光灯に分光計を向けて、スペクトルを見るこ
とです。スペクトルは、下に示す(ピークは強度が異なるかもしれませんが)様に見えるは
ずです。
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 7 OF 22
RMDI system.doc
Resonance ソフトウエア-の操作
3-2
Resonance は分光計の操作のためにエクセルスプレッドシートのマクロスクリプトファイル
(付録 3 を参照)を供給しています。このファイルは、エクセルファイルへ約 310、313 および
315nm の SO2 の3ラインの強度の自然対数を送ります。 ソフトの操作:
1.
提供されるエクセル・テンプレートを開きます。テンプレートが利用可能でない場合エク
セルが起動し、スプレッドシートにデータをログインします。テンプレートはさらにグラ
フ・インターフェースを提供します。しかし、折れ線グラフを作ることは容易にこれを作
成するかもしれません。データがファイルに入るとともに、折れ線グラフを見ることによ
りデータのリアルタイムのプロットを見ることが可能です。
テンプレート RMDI EXCEL Template.xls を下に示します。
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 8 OF 22
RMDI system.doc
2
ここではエクセルは使用可能で、ワークシートは開いているとします。Ocean Optics のソ
フトウェアを起動します。
3
マクロプログラムのロード
a. <Script/Show IDE>を選択する。
b. IDE window で File/Open/RMDI Script 6.bas を選択する。
ここで、Ocean Optics プログラム下で、Resonance マクロソフトウェアを操作する準備ができまし
た。ソフトウェアファイル RMDI Script6.bas は極度にコメントされ、ユーザは修正することがで
きます。それは、3 つの選択された吸収ピークでの SO2 による吸光度を測定するために設定され
ます。これらは、310.8、 313.1 315.4nm の SO2 吸収帯中心です。これらのバンドの吸光度は Beer
Lambert 方程式を使用して計算されます:
plα = -ln(I/I0)
ここで:
pl = 測定ガス (SO2) 濃度 × パス長 (ppm-m)
α = 選択した波長での SO2 の吸収係数(ppm-m) –1
I/I0 = 選択した波長でのガスの透過率
I0 は、選択した波長のどちらか一方の横の強度の平均です。また、I は波長の中心の強度です。こ
の単純な方法は、単純化された COSPEC マスクの使用に相当します。それは評価を目的とするも
ので、機器がより完成されたものになるとともに、マスク(マクロのアップロードによる)上の改
良は無償で提供されるます。
4 Macro run をクリックしマクロを実行してください。これは EXCEL テンプレートへデー
タを取り込みます。観察が終了したら、異なるファイル名で EXCEL テンプレートを保存
することが重要です。
5 スペクトルも、Ocean Optics メニューの中で保存オプションを使用することにより保存で
きます。スペクトルは、Ocean Optics メニューの中で Time acquistion メニューを使用する
ことにより自動的に保存できます。このモジュールを使用する時には、非常に有用な
Ocean Optics Help ファイルを参照してください。
6 一般に、屋外での測定では、正午くらいでは、200 ミリ秒の積算で 1 回平均、あるいは、
黄昏、あるいは非常な曇りの状態では、6 回の平均を取る程度がベストとなります。エク
セルでの取り込みは、各データ積算時間 x 平均回数に約 0.85 秒を加える分遅くなります。
1 データ当り、200 ミリ秒積算で、1 回平均を取った場合は約 1.1 秒、および 200 ミリ秒積
算で 5 回平均の場合で約 2 秒になります。この時間はエクセルファイルに出力され、デー
タの正確な時間積算により、風速がわかっている場合、データ上で流量を見積もることが
可能になるかもしれません。
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 9 OF 22
RMDI system.doc
Appendix 1. SPECTROMETER SPECIFICATIONS
Date: Jan. 19, 2004
Initial:
Identification:
Spectrometer Model/Serial Number: RMDI /040121
Entrance Slit:
Type
Height/Width
Fixed
1 mm/0.025mm
Exit Detector:
Type
Pixel
`
Array Width
Spectral coverage
Spectral coverage with UV filter
Linear CCD
200 x 14 microns
28 mm
295 to 437 nm
295 to 385 nm
Grating:
Grooves/mm
UV type
Resolution/System
2,400/mm
< 0.4 nm first order
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 10 OF 22
RMDI system.doc
Appendix 2: SPECTROMETER CALIBRATION
Date: Jan. 19,2004
Initial:
Equipment:
Spectrometer Model/Serial Number RMDI /
............................................................................................................. Fixed 25 micron slit
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 11 OF 22
RMDI system.doc
Appendix 3: Script File Listing
'SCRIPT FILE NAME RMDI Script 6.bas
' The following script was based on the excelinterface.bas which was script file in Ocean
Optics Platinum Software package
' Script files are written in The Sax Basic Language which provides the core language
definition.
' Sax Basic is Visual Basic for Applications(TM) compatible.
' Sax Basic and Sax Basic Editor are products of Polar Engineering And Consulting
' BEORE RUNNING THIS SCRIPT, YOU MUST ADD A REFERENCE TO THE
' MICROSOFT EXCEL TYPE LIBRARY. YOU MUST SELECT EDIT | REFERENCES.
and check off the reference
' compatible with the version of Excel run on the host computer e g. MICROSOFT EXCEL
XX OBJECT LIBRARY (YY)
'
' The resonanceexcelinterface1.bas script used the MICROSOFT EXCEL 9.0 OBJECT
LIBRARY(1.3)
'
' ALSO, MAKE SURE EXCEL IS OPEN PRIOR TO RUNNING THE MACRO AND
THE EXCELTEST.XLS WORKBOOK (or Worksheet in earlier versions of Excel)
' IS OPEN IN EXCEL BEFORE YOU EXECUTE THIS MACRO
' LOG OF Changes AND ADDITIONS TO THE EXCEL INTERFACE SOFTWARE (by
Bill Morrow [email protected] on June 2,03)
' 1. change program name to resonanceexcelinterface
'
2. set references as above xx = 9.0 and (1.3) part of reference. This process is self
explanitory BUT
'
it is vitally important not to use two excel references at once. (e g. Excel 5.0 and
9.0 references
'
simultaneously
' 3. Add in integrate module which integrates over wavelength ranges.
'
3a. Use Simpsons rule integration (A MODULE IN OO). Normalize each signal to
1 nanometer by dividing by wl2-wl1
'
4. Set up five wavelengths which includes two background wavelengths at 281 and
292 nm (to estimate of scattered light)
'
and three wavelengths around an SO2 absorption band at 309.6 nm
'
5. Calculate band strength by averaging signal on either side and taking ratio with
signal on line
'
6. Use a linear extrapolation of the signal at 292 (based on the slope between 281
and 292) to estimate scattered light
' 7. Remove spectra recording in excel
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 12 OF 22
RMDI system.doc
'============================================================
'============================================================
'
DO NOT MODIFY THE FOLLOWING BLOCK OF CODE
Option Explicit
' #uses "classes\menuverify.bas"
Global ooi As OOIBase32Platinum
Global Ready As Integer
Global Const INITDONE=66
Global InEvent As Boolean
'
END NONMODIFYABLE BLOCK
'============================================================
'============================================================
'############################################################
'############################################################
' Insert global variables here
'############################################################
'############################################################
' declare all excel objects
Global oXL As Excel.Application
Global oWB As Excel.Workbook
Global oSheet As Excel.Worksheet
' define global arrays for wavelength and intensity
Global i As Integer
Global j As Integer
Global jmax As Integer
Global NWL1 As Integer
Global NWL2 As Integer
'Global PixCount As Integer
Global wl(2048) As Double
Global data(2048) As Double
Global Spect_StWL As Double
Global Spect_EnWL As Double
Global Spect_Stpix As Integer
Global Spect_Enpix As Integer
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 13 OF 22
RMDI system.doc
Global Spect_Array(2048) As Integer
Global chan As SPECCHANNEL
Global WLO As Double
'Wavelength offset parameter
Global WLM As Double
'Wavelength multiplier parameter
Global CWL1(15) As Double 'Center Wavelength array for SO2 slit set (nanometre units)
Global CWL2(15) As Double 'Center Wavelength array for Ozone slit set (nanometre units)
Global SHW1(15) As Double 'Slit HALF width array for SO2 slit set (nanometre units)
Global SHW2(15) As Double 'Slit HALF width array for Ozone slit set (nanometre units)
Global Stpix1(15) As Integer
Global Enpix1(15) As Integer
Global Stpix2(15) As Integer
Global Enpix2(15) As Integer
Global BaseRat309 As Double
Global BaseRat311 As Double
Global BaseRat313 As Double
Global StartTimer As Double
Public Sub EventGenerator_MacroBegin(ByVal modname As String)
'============================================================
'============================================================
'
DO NOT MODIFY THE FOLLOWING BLOCK OF CODE
If Ready=INITDONE Then Exit Sub
InEvent=False
Set ooi=New OOIBase32Platinum
'
END NONMODIFYABLE BLOCK
'============================================================
'============================================================
'############################################################
'############################################################
' Insert your start-up code here
'############################################################
'############################################################
' get the wavelength array
ooi.SpectralData.GetWavelengths(chan,wl(0))
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Page 14 OF 22
Operating Manual
Resonance Micro-DOAS RMDI
RMDI system.doc
j=0
jmax = 10000
' set starting and ending wavelengths
'Compressed Spectrum Mask
Spect_StWL = 308
Spect_EnWL= 356.03
'SO2 MASK
WLO = 0
used to correct for temp drift
WLM = 1
to correct for temp drift
'Wave length offset can be
'Wave length span can be used
NWL1 =9
'Number of slits
CWL1(1) = 270*WLM+WLO'Center wavelength 1 background reference
SHW1(1)
= .25*WLM
'Slit 1 half width corrected for wave
length span
CWL1(2) = 280*WLM+WLO'Center wavelength 2 background reference
SHW1(2)
= .25*WLM
'Slit 2 half width ....
CWL1(3) = 309.77*WLM+WLO 'Center wavelength 3 low SO2 absorption
SHW1(3)
= 0.25*WLM
'Slit 3 half ...
CWL1(4) = 310.75*WLM+WLO 'Center wavelength 4 high SO2 absorption
SHW1(4)
= 0.25*WLM
'Slit 4 half width ...
CWL1(5) = 312.1*WLM+WLO 'Center wavelength 5 low SO2 absorption
SHW1(5)
= 0.25*WLM
'Slit 5 half width ...
CWL1(6) = 313.08*WLM+WLO 'Center wavelength 6 high SO2 absorption
SHW1(6)
= 0.25*WLM
'Slit 6 half width ...
CWL1(7) = 314.16*WLM+WLO 'Center wavelength 7 low SO2
absorption
SHW1(7)
= 0.25*WLM
'Slit 7 half width ...
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 15 OF 22
RMDI system.doc
CWL1(8) = 315.43*WLM+WLO 'Center wavelength 8 high SO2
absorption
SHW1(8)
= 0.25*WLM
'Slit 8 half width ...
CWL1(9) = 316.52*WLM+WLO 'Center wavelength 9 low SO2 absorption
SHW1(9)
= 0.25*WLM
'Slit 9 half width ...
BaseRat309 = 1.22
BaseRat311 = 1.01
BaseRat313 = 1.01
'OZONE MASK
NWL2 = 5
CWL2(1) = 306.3*WLM+WLO
SHW2(1)
= 0.25*WLM
'Slit 1 half width corr for wave length span
CWL2(2) = 310.0*WLM+WLO
SHW2(2)
= 0.25*WLM
'Slit 2 half width...
CWL2(3) = 313.5*WLM+WLO
SHW2(3)
= 0.25*WLM
'Slit 3 half width...
CWL2(4) = 316.8*WLM+WLO
SHW2(4)
= 0.25*WLM
'Slit 4 half width...
CWL2(5) = 320*WLM+WLO
SHW2(5)
= 0.25*WLM
'Slit 5 half width...
' set spectrometer channel
chan=chMaster
' get starting and ending pixel from wavelengths
'For compressed spectrum
Spect_Stpix = ooi.Spectrometer.wavelength.GetPixel(chan,Spect_StWL)
Spect_Enpix = ooi.Spectrometer.wavelength.GetPixel(chan,Spect_EnWL)
'For SO2 mask
For i = 1 To NWL1
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 16 OF 22
RMDI system.doc
Stpix1(i) =ooi.Spectrometer.wavelength.GetPixel(chan,CWL1(i)-SHW1(1))
Enpix1(i) =ooi.Spectrometer.wavelength.GetPixel(chan,CWL1(i)+SHW1(1))
Next i
'For O3 mask
For i = 1 To NWL2
Stpix2(i) =ooi.Spectrometer.wavelength.GetPixel(chan,CWL2(i)-SHW2(i))
Enpix2(i) =ooi.Spectrometer.wavelength.GetPixel(chan,CWL2(i)+SHW2(i))
Next i
'Configure OO Sheet
' create new grid window
'
'
If ooi.SetGridByName("Integration") = False Then
'
ooi.Windows.NewGridWindow(4,30,1,"Integration")
'
Call ooi.SetGridActive()
End If
' name the cells
'
'
ooi.Grid.Format_Grid.ColumnPrecision(1)=2
ooi.Grid.Format_Grid.ColumnPrecision(3)=2
'
'
'
ooi.Grid.Data_Grid.Text(1,1)="Absorb 310.8"
ooi.Grid.Data_Grid.Text(1,2)="Absorb 313.1"
ooi.Grid.Data_Grid.Text(1,3)="Absorb 315.4"
'
For i = 1 To NWL1
'
ooi.Grid.Data_Grid.value(1,i+3)=CWL1(i)
' Next i
'
'
For i = 1 To NWL1 'NWL2
ooi.Grid.Data_Grid.value(1,NWL1+3+i)=CWL2(i)
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 17 OF 22
RMDI system.doc
' Next i
' set numerical precision and format
'
'
'
'
'
'
'
'
ooi.Grid.Format_Grid.ColumnPrecision(2)=2
ooi.Grid.Format_Grid.ColumnPrecision(4)=2
ooi.Grid.Format_Grid.ColumnExponentialFormat(2)=True
ooi.Grid.Data_Grid.value(2,1)=1000000000
ooi.Grid.Format_Grid.ColumnPrecision(4)=4
ooi.Grid.Format_Grid.ColumnExponentialFormat(4)=True
ooi.Grid.Data_Grid.value(2,1)=1000000000
size the columns
'
ooi.Grid.Format_Grid.AutosizeColumn(1,2,3,bfSizeBestFit)
'END comment out for excel
' initialize communication with excel
Set oXL=GetObject(,"Excel.Application")
Set oWB=oXL.ActiveWorkbook
Set oSheet=oWB.ActiveSheet
' put the wavelengths into the grid in the excel ss
oSheet.Cells(7,1)="Start Time"
oSheet.Cells(7,3)=Str(Time)
StartTimer = Timer
oSheet.Cells(10,1)="sec after start"
oSheet.Cells(10,2)="Absorb 310.8"
oSheet.Cells(10,3)="Absorb 313.1"
oSheet.Cells(10,4)="Absorb 315.4"
'
For i = 1 To 237
'
'
oSheet.Cells(10,18+i)=wl(Spect_Stpix+i*3)
Next i
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
'
Operating Manual
Resonance Micro-DOAS RMDI
Page 18 OF 22
RMDI system.doc
For i = 1 To NWL1
'
oSheet.Cells(10,4+i)=CWL1(i)
' Next i
'
For i = 1 To NWL2
'
oSheet.Cells(10,4+NWL1+i)=CWL2(i)
' Next i
'============================================================
'============================================================
'
DO NOT MODIFY THE FOLLOWING BLOCK OF CODE
Ready=INITDONE
'
END NONMODIFYABLE BLOCK
'============================================================
'============================================================
End Sub
Public Sub EventGenerator_NewSpectraReady(ByVal windowname As String, ByVal
channels As Integer)
'============================================================
'============================================================
'
DO NOT MODIFY THE FOLLOWING BLOCK OF CODE
If Ready<>INITDONE Then Exit Sub
If ooi.InNextScanWait=True Then
ooi.InNextScanWait=False
Exit Sub
End If
If ooi.InTimeWait=True Then Exit Sub
If InEvent=True Then Exit Sub
InEvent=True
'
END NONMODIFYABLE BLOCK
'============================================================
'============================================================
'############################################################
'############################################################
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 19 OF 22
RMDI system.doc
' Insert your event code here
'############################################################
'############################################################
' this On Error statement is necessary. when you edit a cell
' in Excel while the script is running, Excel generates an
' error. automation clients are unalbe to access cell contents
' while it is being edited. the On Error statement causes the
' script to gracefully continue
On Error Resume Next
' with each new spectrum, get the desired wavelength
' Dim wl As Double
' wl=340 ' oSheet.Cells(5,3)
' define local variables
Dim M As Double
Dim X As Double
Dim B As Double
Dim RFlux1(9)
Dim CRFlux1(9)
Dim CRFlux2(5)
Dim RFlux2(5)
Dim CurPix As Integer
' get processed spectral data
ooi.SpectralData.GetProcessedSpectrum(chMaster,data(0))
'************* Create compressed spectrum ****************
'Create average
' integrate
For i =1 To NWL1
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 20 OF 22
RMDI system.doc
RFlux1(i) = 0
For CurPix = Stpix1(i) To Enpix1(i)
RFlux1(i) = RFlux1(i) + data(CurPix)
Next CurPix
RFlux1(i) = RFlux1(i)/(Enpix1(i)-Stpix1(i))
Next i
For i =1 To NWL2
RFlux2(i) = 0
For CurPix = Stpix2(i) To Enpix2(i)
RFlux2(i) = RFlux2(i) + data(CurPix)
Next CurPix
RFlux2(i) = RFlux2(i)/(Enpix2(i)-Stpix2(i))
Next i
' USE CODE BELOW IF DATA GOING TO EXCEL
' put the data into the excel spreadsheet
j = j+1
M = (RFlux1(2)-RFlux1(1))/(CWL1(2)-CWL1(1))
B = RFlux1(1)
For i = 1 To 2
CRFlux1(i) = RFlux1(i)
Next i
For i = 3 To NWL1
X = CWL1(i) - CWL1(2)
CRFlux1(i) = RFlux1(i) - B '(M*X+ B)
Next i
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 21 OF 22
RMDI system.doc
For i = 1 To NWL2
X = CWL2(i) - CWL1(2)
CRFlux2(i) = RFlux2(i) - B '(M*X+ B)
Next i
ooi.oSheet.Cells(10+j,1)= Str(Timer-StartTimer)
ooi.oSheet.Cells(10+j,2)= Log(2*CRFlux1(4)/(CRFlux1(3)+CRFlux1(5))/BaseRat309)
ooi.oSheet.Cells(10+j,3)= Log(2*CRFlux1(6)/(CRFlux1(5)+CRFlux1(7))/BaseRat311)
ooi.oSheet.Cells(10+j,4)= Log(2*CRFlux1(8)/(CRFlux1(7)+CRFlux1(9))/BaseRat313)
'
For i =1 To NWL1
'
'
ooi.oSheet.Cells(10+j,4+i)= RFlux1(i)
Next i
'
For i =1 To NWL2
'
'
ooi.oSheet.Cells(10+j,i+4+NWL1)= RFlux2(i)
Next i
'Put continuous spectrum into Excel
'
For i = 1 To 237
'
oSheet.Cells(10+j,18+i)=(data(Spect_Stpix+i*31)+data(Spect_Stpix+i*3)+data(Spect_Stpix+i*3+1))/3
'
Next i
' USE CODE BELOW IF DATA GOING TO SHEET IN OOI32 PLAT
' put the data into the grid in the ooibase sheet
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002
Resonance Ltd.
Electro-Optics Research,
Development and Manufacturing
Operating Manual
Resonance Micro-DOAS RMDI
Page 22 OF 22
RMDI system.doc
'
ooi.Grid.Data_Grid.value(2,1) = -Log(2*RFlux1(4)/(RFlux1(3) +
RFlux1(5))/BaseRat309)
'
ooi.Grid.Data_Grid.value(2,2) = -Log(2*RFlux1(6)/(RFlux1(5) +
RFlux1(7))/BaseRat311)
'
ooi.Grid.Data_Grid.value(2,3) = -Log(2*RFlux1(8)/(RFlux1(7) +
RFlux1(9))/BaseRat313)
'
ooi.Grid.Data_Grid.value(3,1) = Log(2*CRFlux1(4)/(CRFlux1(3)+CRFlux1(5))/BaseRat309)
'
ooi.Grid.Data_Grid.value(3,2) = Log(2*CRFlux1(6)/(CRFlux1(5)+CRFlux1(7))/BaseRat311)
'
ooi.Grid.Data_Grid.value(3,3) = Log(2*CRFlux1(8)/(CRFlux1(7)+CRFlux1(9))/BaseRat313)
'
For i =1 To NWL1
'
'
ooi.Grid.Data_Grid.value(2,i+3)= RFlux1(i)
ooi.Grid.Data_Grid.value(3,i+3)= CRFlux1(i)
'
Next i
'
For i =1 To NWL2
'
'
'
ooi.Grid.Data_Grid.value(2,i+NWL1+3)= RFlux2(i)
ooi.Grid.Data_Grid.value(3,i+NWL1+3)= CRFlux2(i)
Next i
'============================================================
'============================================================
'
DO NOT MODIFY THE FOLLOWING BLOCK OF CODE
InEvent=False
'
END NONMODIFYABLE BLOCK
'============================================================
'============================================================
End Sub
Resonance LTD.
143 Ferndale Drive North, Barrie. Ontario, Canada, L4N 9V9. Phone (705) 733-3633, FAX (705) 733-1388
www.resonance.on.ca
[email protected]
Resonance Ltd, Canada, 2002