Download SCRUBTEC 343B

Transcript
ENGLISH
USER MANUAL
TROUBLESHOOTING
Trouble
Possible Cause
The motors do not turn on; no warning light turns
on.
The battery terminals (50) are disconnected.
Connect.
The batteries (50) are discharged.
Charge.
The vacuum system motor does not turn on.
The fuse is blown.
Replace.
The recovery water tank (31) is full.
Empty.
The vacuum grid (46) is clogged or the float
is closing.
Clean the grid and check the float.
The vacuum hose (22) is disconnected from
the squeegee (11) or it is damaged.
Connect.
The squeegee (11) is dirty, or the squeegee
blades (13 - 14) are worn or damaged.
Clean the squeegee or replace the blades.
The recovery water tank cover (6) is not
properly closed, or the gasket (42) is
damaged.
Check and/or clean the seating surface or
replace the gasket.
The recovery water tank (31) is dirty
(clogged drain hole).
Clean.
The solution filter (20) is dirty.
Clean.
There is debris under the squeegee blades
(13 - 14).
Remove the debris.
The squeegee blades (13 - 14) are worn,
chipped or torn.
Replace the blades.
The dirty water vacuuming is insufficient.
The solution flow is insufficient.
Remedy
The squeegee leaves marks on the floor.
For further information refer to the Service Manual, available at any Alto Service Center.
SCRAPPING
Have the machine scrapped by a qualified scrapper.
Before scrapping the machine, remove and separate the following materials, which must be disposed of properly according to the
Law in force:
–
Battery
–
Brushes
–
Plastic hoses and components
–
Electrical and electronic components (*)
(*)
Refer to the nearest Alto Center especially when scrapping electrical and electronic components.
22
SCRUBTEC 343B
909 6313 000(2)2007-06 A