Download GRUNDFOS INSTRUCTIONS
Transcript
1.3 MQ pump Fig. 1 Control panel Pressure tank Discharge port Priming plug Suction port TM01 9873 2600 Plug Drain plug Base plate 2. Pumped liquids Thin, clean, non-aggressive liquids, not containing solid particles or fibres. 3. Technical data 3.1 Operating conditions Maximum pressure [bar] MQ 3-25 MQ 3-35 MQ 3-45 2.5 3.5 4.5 Maximum system pressure [bar] 7.5 Maximum suction lift [m], see page 93 8 Minimum ambient temperature [°C] 0 Maximum ambient temperature [°C] 45 Minimum liquid temperature [°C] 0 Maximum liquid temperature [°C] 35 Net weight [kg] 13.0 Sound pressure level [dB(A)] < 70 Tank volume [l] Air pressure in tank [bar] 0.16 1.0 1.5 to 1.7 50 Hz: Maximum flow rate [m³/h] 4.5 Connections G1 60 Hz: Maximum flow rate [m³/h] Connections 5 1" NPT 5