Download Operating Instructions Type 2702
Transcript
Maintenance and Servicing of the valve Replacement of the plug with SideControl Type 1067 Caution! Use of the incorrect lubricant causes contamination! For special applications such as for oxygen and analysis, use only the approved lubricants. english Demounting the actuator Dismount the piston actuator as described below. You will avoid damage to the gaskets because the piston will be brought into the upper position. Connect compressed air at 4.5 to 6 bar to P (1). Remove the blowout mouthpiece. Unscrew the 4 screws. Open the cover (2). The 2 red switches for emergency manual actuation (3) are located next to the terminal strip. They are in the idle position when the arrow is parallel to the terminal strip. Turn the 2 switches carefully 90 degrees in the clockwise direction (in either order) (4a). The piston moves into the upper position and the plug is separated from the valve seat. Turn only the upper switch to the idle position (4b). The piston stays in the upper position even after the compressed air is switched off. 28 - 2702