burns if the poles of the battery are shortcircuited by hand or by means of conducting objects. 2.2 Improper use Any use of the machine for purposes not covered under "Prescribed usage" or contractually agreed on is not permissible. Operation of the machine in unserviceable condition or not in compliance with the following instructions is prohibited. – Protective devices must not be removed or bypassed. – Conversions and modifications to the product are not permitted. 2.3 Organizational points It is the responsibility of the operator to ensure that – the machine is used only by persons who have been instructed in its handling and expressly authorized to use it. – the recognized occupational safety rules are observed. – any further national or internal company regulations are observed. – all users are acquainted with the safety regulations and have been trained in the use of the specific machine. – all users have read and understood the operating instructions before using the machine. – the responsibilities for operation, maintenance and repair of the machine are clearly assigned and observed. – faults and damage are immediately reported to the Wetrok Service Agent. 2.4 Emergencies Following incidents, do not put the machine into operation again before it is checked by Wetrok. 2.5 Operating for the first time Delivery, instruction on safety regulations, handling and maintenance as well as operation for the first time are normally carried out by a specialist approved by Wetrok. Where this is not the case, the operator is responsible for instructing the users. Further safety instructions concerning operation and maintenance are detailed in the relevant sections and must be complied with! 3. Operation 3.1 Safety instructions – Before the machine is used, the tank (upper part of machine) and the tank cover must be closed and locked and the key withdrawn. – Remove the key from the main switch when travelling on elevators. – During operation, caution should be exercised with respect to third parties, especially children. – To avoid injuries, wear sturdy footwear. – When cleaning and servicing the machine, changing parts or exchange brushes, switch off the drive and withdraw the key from the main switch. – Only original Wetrok cleaning attachments must be used. – Do not drive on slopes with more then 8% gradients. – When the machine is not in use remove the key from the main switch in order to avoid unintentional movement or unauthorized use. – Before working on electrical installations, the cable between batteries and machine must be disconnected. 3.2 Restrictions on use The machine is not to be used at temperatures below 0°C. The water temperature must not exceed 50°C. 3.3 Fitting attachments, making adjustments The choice of cleaning agent and attachments depends on the type of floor and its degree of soiling. Basic cleaning or severe soiling: Wetrok Remat or Antiwax/Exal, dosage 1:20. Smooth floors: pad drive disc with black or green Wetrok Polypad. Rough floors (e.g. natural stone): scrubbing brush. Upkeep cleaning: Wetrok Redur or Resal, dosage 1:100. Pad drive disc and green or red Polypad, possibly scrubbing brush. Do not use foaming cleaning agents or flammable solvents. Fitting the cleaning attachments: – Only original Wetrok cleaning attachments must be used. Place working elements under brush unit line up as close as possible, ( if using pad drive discs attach pad to discs first). To start the semi automatic coupling cycle press brush coupling switch (C 8) wait until cycle is complete. If necessary the semi automatic coupling cycle can be stopped by pressing switch (C 8) again. Caution, on sensitive floor coverings it is advisable to attach the working elements manually. Adjusting the suction nozzle The ideal angle for the suction nozzle depends on the type of floor. In the basic position, the nozzle should rest flat on the floor. With the machine in motion, turn the angle setting screw (A 10) until the optimal suction effect is obtained. 3.4 Operation Putting the machine into operation – Switch on key-operated main switch – Switch on brush motor: the brush unit lowers automatically to a standby position – Switch on suction motor: the suction nozzle lowers automatically – On driving away the brush motor starts and lowers to the floor, the brush pressure adjusts and the water supply opens automatically. Driving lever upwards = forward movement Driving lever downwards = reverse movement If the machine is stationary for more than 3 seconds, the brush motor and the water supply automatically switchs off. Depending on the degree of soiling, the brush pressure and the water supply can be readjusted with the pushbuttons (C 10 + C 3). The water supply and brush pressure revert to their basic settings when the machine is switched off with the main key switch. Working method – Sweep or dump mop floor first. – Choose long driving distances wherever possible. – When working in strips, overlap the edge of the clean surface by about 3 - 5 cm in the next pass. – Adjust water supply and driving speed to the degree of soiling of the floor. – Always supply sufficient water. The detached dirt should be washed away with as much liquid as possible and sucked up. – Heavily soiled floors (even before basic cleaning) should first be wet with cleaning solution and this should be allowed to act for a few minutes. Parking and emergency brake Removing the cleaning attachments The machine can be abruptly stopped by pressing the emergency brake bar (C 5) when an obstacle is suddenly encountered. Raise the brush housing to the upper position. Operate brush ejection lever (B 4) with the foot. Driving on inclines Filling with fresh water/cleaning agent: – Lift up tank cover – Fill fresh water tank with water – Add desired cleaning agent in the prescribed dose. Dosage instructions must be followed. – Close tank cover Driving on a slope, the speed of the machine can be regulated with the drive lever. Do not drive on slopes with more then 8% gradients. Monitoring of battery discharge The green indicator lamp (C 6) lights up when the batteries are fully charged. The yellow lamp lights up to indicate imminent discharge (only around another 20 min of operating time). The final discharge is indi17