Download StecaGrid Vision
Transcript
EN Inverter addresses This menu item allows you to set the number of connected inverters and define their individual addresses. Use the UP and DOWN buttons to set the desired address value. Pressing the SET button confirms the value and moves to the next setting. The number of inverters must be set first. After this you can set the addresses of each inverter. The number of displayed inverters is the same as the number of defined inverters. If a duplicate address is entered then a warning is displayed at the lower edge of the screen. Once you have set all values you must press the SET button once more to save these settings. If a duplicate address still exists at this time then the first inverter with a duplicate address is displayed so that you can directly change this address to a unique value. 8.3 Alarm This menu item allows you to define how (Settings) and at what values (Thresholds) the remote display should provide notification in the case of an alarm. Alarm options The following settings are possible for acoustic and visual alarms: Acoustic alarm (= permanent tone sequence) • On / Off • Volume: quiet / normal / loud • Alarm period per day: start time / stop time Visual alarm (= blinking display illumination) On / Off Alarm threshold If an inverter drops below its threshold value then a low yield alarm is triggered. The threshold value is defined as a percentage value of the average daily yield over all inverters. 734.144 | 10.48 49