Download CPP1000-M CPP1000-L - AV Measurement & Control (India)

Transcript
Hand Spindle Pump
CPP1000-M/-L
GB If the blind plug is removed completely, a small
cylindrical body, made of red plastic, is visible.
This plastic body is to reduce the internal
volume of the pump if a shut-off valve or fine
adjustment valve is not used / mounted.
Remove the red cylindrical body using tweezers
or blow it out through the open test connection
using compressed air.
Now the three rings have to be placed in the
pump (only with shut-off valve; Order No.
11208384). You may not place the three rings
on the mandrel of the valve, you must place
the gasket rings inside the pump, according to
following instructions:
11178035 06/2006 GB/D
First, insert one of the two supporting rings
(made of white PTFE) (only with shut-off valve;
Order No. 11208384).
Make sure that the supporting ring is fitted well.
18
WIKA Operating Instructions Hand Spindle Pump